1 Release Notes for FRS_4.58
The following provides release information for Oracle’s StorageTek SL3000 library firmware version FRS_4.58.
Enhancements
- Added support for LTO-9.
- Added support for media validation of LTO cartridges using IBM LTO-6+ drives with media L4 and higher.
- Implemented LTO media validation for IBM drives in ADI mode.
- Added a device watchdog on the drive controller.
- Increased the load and unload timeouts to 16.5 minutes to cover the extended timeouts for IBM LTO-7+ drives per IBM specification.
- For the CLI, drive stateSave <drive address> is now available for the user admin.
- The SNMP MIB version is now 2.21 which corrected OIDs slDriveHealthStatusEnum and slLibMibVer.
Fixes
- Corrected handing of health check and last communication setting to prevent 3997’s (message queue size) with the HBT card.
- Serialized handling of multiple announces of the same drive to prevent drive initialization and robot issues.
- Corrected how the drive controller handles the watchdog when requests are received for multiple drives.
- Stopped sending duplicate announce IBM drive resets after a drive firmware update.
- The drive tray now sends fan2 presence and status to the library controller for all drive trays.
- Modified code to mitigate HBT2 cards clock drift.
Library Support of Tape Calibration
IMPORTANT: IBM has stated that the calibration of a new L9 cartridge can take anywhere from 20 minutes to 2 hours to complete.
With the FRS_4.58 code release, the library supports longer load times. However, tape calibration well exceeds these load times. Thus, library support has been modified to better handle tape calibration.