Access Module (AEM)

An Access Module has a cartridge access door used for bulk loading of up to 234 tapes. A library with two Access Module supports the redundant robotics feature.

A sliding safety door in the Access Module can separate a defective robot from the rest of the library, allowing a service representative to access the disabled robot while the library remains online.

  • Access Modules must be placed on the ends of the library.
  • A single Access Module supports bulk loading CAP capabilities only. You should install a single Access Module on the left for an additional 104 storage cells.
  • Dual Access Modules support bulk loading and redundant robotics.
  • Access Modules and Parking Modules cannot be installed in the same library.

Figure 1-7 Access Module

Access Module with end cover off
  1. Side cover removed showing sliding door
  2. Bulk load cartridge access door
  3. Access module service panel and handle

Access Module Measurements

Dimension Measurement

Height

196.7 cm (77.45 in.) on casters for transport

197.5 cm (77.75 in.) to 201.68 cm (79.4 in.) on jack pads for permanent install

Width

91.4 cm (36.0 in.) when placed between module and side cover

96 cm (37.8 in) transport width (no side covers). This is the minimum transportation clearance because alignment tabs on each side of the module add 4.5 cm to the 91.5 cm width.

99.1 cm (39 in.) with one side cover

Depth

77.5 cm (30.5 in.)

Service Area

Front: 59.7 cm (23.5 in.)

Weight

Frame only: 204.2 kg (450 lb)