Oracle ZFS Storage ZS11-2 Electrical Specifications
The Oracle ZFS Storage ZS11-2 controller has two highly redundant, hot-swappable, rear accessible power supplies with N+N redundancy. The A271 1400W power supply accepts ranges of 200-240 VAC high-line and requires high-line power supplies require high-line 200-240 VAC sources. To understand the overall power consumption, see Oracle's online power calculator at http://www.oracle.com/goto/powercalculators.
| Power Supply Parameter | Model A271 |
|---|---|
|
Electrical ratings |
200-240V~, 10A, 50/60Hz (x2) |
|
Voltage (nominal) |
200-240 VAC |
|
Input current (maximum) |
10.0A at 200-240 VAC |
|
Frequency (nominal) |
50/60 Hz (47-63 Hz range) |
|
Maximum power consumption |
1400W at AC 200V-240V |
| Controller Parameter | Corresponding Entry in Power Calculator |
|---|---|
|
Maximum power consumption of controller |
Refer to the Power Calculator (https://www.oracle.com/goto/powercalculators) and see Oracle ZFS Storage ZS11-2 for Watt calculations |
|
Maximum heat output of controller |
Refer to the Power Calculator (https://www.oracle.com/goto/powercalculators) and see Oracle ZFS Storage ZS11-2 for BTU/hr calculations. |