Oracle ZFS Storage ZS3-4 PCIe I/O Cards
Oracle ZFS Storage ZS3-4 PCIe Options - This table describes the PCIe base configuration and optional slot assignments for Oracle ZFS Storage ZS3-4 standalone and cluster configurations.
Table 10-3 Oracle ZFS Storage ZS3-4 Controller PCIe Options
| Slot | Mfg Part Number | Description | Max | Note |
|---|---|---|---|---|
|
0 |
7047852 |
8-port SAS-2 internal HBA |
1 |
Base configuration |
|
1 |
7067091 |
4-port (4x4) SAS-2 external HBA |
4 |
Base configuration |
|
2 |
7067091 |
4-port (4x4) SAS-2 external HBA |
4 |
Additional optional back-end |
|
2 |
7070006 |
2-port 10Gb Ethernet Copper NIC |
4 |
Optional recommended front-end |
|
2 |
375-3696-01 |
2-port InfiniBand CX2 HCA |
4 |
Optional recommended front-end |
|
2 |
7070195 |
4-port 1Gb Ethernet Copper UTP NIC |
4 |
Optional recommended front-end |
|
2 |
7051223 |
2-port 10Gb Ethernet Optical NIC |
6 |
Optional recommended front-end |
|
2 |
371-4325-02 |
2-port 8Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
2 |
7023303 |
2-port 16Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
3 |
7070006 |
2-port 10Gb Ethernet Copper NIC |
4 |
Optional recommended front-end |
|
3 |
375-3696-01 |
2-port InfiniBand CX2 HCA |
4 |
Optional recommended front-end |
|
3 |
7070195 |
4-port 1Gb Ethernet Copper UTP NIC |
4 |
Optional recommended front-end |
|
3 |
7051223 |
2-port 10Gb Ethernet Optical NIC |
6 |
Optional recommended front-end |
|
3 |
371-4325-02 |
2-port 8Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
3 |
7023303 |
2-port 16Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
4 |
7070006 |
2-port 10Gb Ethernet Copper NIC |
4 |
Optional recommended front-end |
|
4 |
375-3696-01 |
2-port InfiniBand CX2 HCA |
4 |
Optional recommended front-end |
|
4 |
7070195 |
4-port 1Gb Ethernet Copper UTP NIC |
4 |
Optional recommended front-end |
|
4 |
7051223 |
2-port 10Gb Ethernet Optical NIC |
6 |
Optional recommended front-end |
|
4 |
371-4325-02 |
2-port 8Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
4 |
7023303 |
2-port 16Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
C |
511-1496-05 |
Cluster Controller 200 |
1 |
Cluster base configuration |
|
5 |
7070006 |
2-port 10Gb Ethernet Copper NIC |
4 |
Optional recommended front-end |
|
5 |
375-3696-01 |
2-port InfiniBand CX2 HCA |
4 |
Optional recommended front-end |
|
5 |
7070195 |
4-port 1GbE UTP Ethernet |
4 |
Optional recommended front-end |
|
5 |
7051223 |
2-port 10Gb Ethernet Optical NIC |
6 |
Optional recommended front-end |
|
5 |
371-4325-02 |
2-port 8Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
5 |
7023303 |
2-port 16Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
6 |
7070006 |
2-port 10Gb Ethernet Copper NIC |
4 |
Optional recommended front-end |
|
6 |
375-3696-01 |
2-port InfiniBand CX2 HCA |
4 |
Optional recommended front-end |
|
6 |
7070195 |
4-port 1Gb Ethernet Copper UTP NIC |
4 |
Optional recommended front-end |
|
6 |
7051223 |
2-port 10Gb Ethernet Optical NIC |
6 |
Optional recommended front-end |
|
6 |
371-4325-02 |
2-port 8Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
6 |
7023303 |
2-port 16Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
7 |
7067091 |
4-port (4x4) external HBA |
4 |
Additional optional back-end |
|
7 |
7070006 |
2-port 10Gb Ethernet Copper NIC |
4 |
Optional recommended front-end |
|
7 |
371-4325-02 |
2-port 8Gb FC HBA |
4 |
Optional recommended front-end |
|
7 |
375-3696-01 |
2-port InfiniBand CX2 HCA |
4 |
Optional recommended front-end |
|
7 |
7051223 |
2-port 10Gb Ethernet Optical NIC |
6 |
Optional recommended front-end |
|
7 |
7070195 |
4-port 1Gb Ethernet Copper UTP NIC |
4 |
Optional recommended front-end |
|
7 |
371-4325-02 |
2-port 8Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
7 |
7023303 |
2-port 16Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
8 |
7067091 |
4-port (4x4) SAS-2 external HBA |
4 |
Base configuration |
|
9 |
371-4325-02 |
2-port 8Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
|
9 |
7070006 |
2-port 10Gb Ethernet Copper NIC |
4 |
Optional recommended front-end |
|
9 |
7070195 |
4-port 1Gb Ethernet Copper UTP NIC |
4 |
Optional recommended front-end |
|
9 |
7051223 |
2-port 10Gb Ethernet Optical NIC |
6 |
Optional recommended front-end |
|
9 |
7023303 |
2-port 16Gb FC HBA |
4 |
Optional FC target or initiator (backup) |
Oracle ZFS Storage ZS3-4 NIC/HBA Options - This table describes NIC/HBA PCIe card options for Oracle ZFS Storage ZS3-4 standalone and cluster configurations.
Table 10-4 Oracle ZFS Storage ZS3-4 Controller NIC/HBA Options
| Mktg Part Number | Description |
|---|---|
|
SG-SAS6-INT-Z |
8-port 6Gb/s SAS-2 internal HBA |
|
SG-XPCIE2FC-QF8-Z |
2-port 8Gb FC HBA |
|
7103791 |
4-port (4x4) SAS-2 6Gb/s external HBA |
|
7101674 |
2-port 16Gb FC HBA |
|
7100477 |
4-port 1Gb Ethernet Copper UTP |
|
7100488 |
2-port 10Gb Ethernet Copper Base-T |
|
X4242A |
2-port InfiniBand CX2 HCA |
|
X1109A-Z |
2-port 10GbE SFP+ NIC |
|
X2129A |
Transceiver 850NM, 1/10GPS, Short Reach, SFP |
|
X5562A-Z |
Transceiver 10GbE/1GbE, Long Reach, SFP |
Oracle ZFS Storage ZS3-4 PCIe Slot Order - When installing additional PCIe cards to your base configuration, cards must be added in a specific order.
Note:
Slot 0 is always populated with a SAS-2 internal HBA. Slots 1 and 8 are reserved for 4x4 SAS-2 external HBAs.
Install optional PCIe cards in the following order:
Table 10-5 Oracle ZFS Storage ZS3-4 Controller Optional PCIe Cards and Slot Order
| PCIe Card | Slot Order |
|---|---|
|
1 4-port (4x4) SAS-2 external HBA |
Slot 2, 7 |
|
2 8Gb FC HBA |
Slot 9 |
|
. |
Additional FC HBAs are installed last |
|
3 InfiniBand HCAs |
Slot 3, 6, 4, 5, 2, 7 |
|
4 2-port 10Gb Ethernet NIC |
Slot 3, 6, 4, 5, 2, 7, 9 |
|
. |
Note: If you are adding a 2-port 10Gb Ethernet Optical NIC and 2-port 10Gb Ethernet Copper NIC, the 10Gb Ethernet Optical NIC has slot priority. |
|
5 4-port 1Gb Ethernet NIC |
Slot 3, 6, 4, 5, 2, 7, 9 |
|
6 16Gb FC HBA |
Slot 3, 6, 4, 5, 2, 7, 9 |
|
7 Remaining 8Gb FC HBAs |
Slot 3, 6, 4, 5, 2, 7 (slot 9, see step 2) |