Sun ZFS Storage 7120 PCIe Options
The following table describes the supported PCIe configuration option summary for the Sun ZFS Storage 7120 controller.
Table 11-20 Sun ZFS Storage 7120 Controller PCIe Options
Slot | Type | Sun Part Number | Vendor Part Number | Description | Note |
---|---|---|---|---|---|
0 |
PCIe |
540-7975-03 |
Sun Aura |
Internal Flash HBA Logzilla |
Base Configuration (OBSOLETE) |
0 |
PCIe |
375-3481-01 |
Intel EXPI9404PT |
QP Copper NIC |
Optional Recommended Front-end |
0 |
PCIe |
375-3617-01 |
Intel Niantic |
DP Optical 10GE NIC |
Optional Recommended Front-end |
0 |
PCIe |
371-4325-01 |
QLogic |
8Gb DP FC HBA |
Optional FC Target or Initiator (Backup) |
0 |
PCIe |
375-3606-01 |
Mellanox MHJH29-XTC |
InfiniBand HCA |
Optional Recommended Front-end |
1 |
PCIe |
375-3617-01 |
Intel Niantic |
DP Optical 10GE NIC |
Optional Recommended Front-end |
1 |
PCIe |
375-3606-01 |
Mellanox MHJH29-XTC |
InfiniBand HCA |
Optional Recommended Front-end |
1 |
PCIe |
375-3481-01 |
Intel EXPI9404PT |
QP Copper NIC |
Optional Recommended Front-end |
1 |
PCIe |
371-4325-01 |
QLogic |
8Gb DP FC HBA |
Optional FC Target or Initiator (Backup) |
3 |
PCIe |
375-3665-01 |
Sun Thebe (INT) |
Internal SAS HBA |
Base Configuration |
4 |
PCIe |
375-3481-01 |
Intel EXPI9404PT |
QP Copper NIC |
Optional Recommended Front-end |
4 |
PCIe |
371-4325-01 |
QLogic |
8Gb DP FC HBA |
Optional FC Target or Initiator (Backup) |
4 |
PCIe |
375-3609-03 |
Sun Thebe (EXT) |
8P 6Gb/s SAS HBA |
Additional Optional Back-end |