Oracle VM Server for SPARC 3.6 Administration Guide Setting Up Services and the Control Domain Verifying That the ILOM Interconnect Is Enabled How to Verify the ILOM Interconnect Configuration How to Verify the ILOM Interconnect Configuration Verify that the ilomconfig-interconnect service is enabled.primary# svcs ilomconfig-interconnect STATE STIME FMRI online 9:53:28 svc:/network/ilomconfig-interconnect:default Verify that the ILOM interconnect is configured properly. A proper ILOM interconnect configuration shows the State value as enabled and the Host Interconnect IP Address value as an IP address and not none. primary# ilomconfig list interconnect Interconnect ============ State: enabled Type: USB Ethernet SP Interconnect IP Address: 169.254.182.76 Host Interconnect IP Address: 169.254.182.77 Interconnect Netmask: 255.255.255.0 SP Interconnect MAC Address: 02:21:28:57:47:16 Host Interconnect MAC Address: 02:21:28:57:47:17 Verify that the ldmd daemon can communicate with the SP.primary# ldm list-spconfig