Valid for
Extract, Replicat
Description
Use CONVERTALLFLOATSTOIEEE to convert the Tandem (TDM) float data type numbers used by Oracle GoldenGate for HP NonStop to the Institute of Electrical and Electronics Engineers (IEEE) format used by Oracle GoldenGate for Windows and UNIX. CONVERTALLFLOATSTOIEEE converts all the float data type numbers in a file or table if the following conditions are met:
There is no column mapping for the table or file
Any SQL/MP table is not a view
Definitions are provided for the Enscribe files
CONVERTALLFLOATSTOIEEE converts 64 bit float data types (SQL/MP type float or Enscribe type double.) It does not convert 32 bit float data types (SQL/MP Real or Enscribe type float) because these are converted by Oracle GoldenGate for Windows and UNIX.
Use CONVERTALLFLOATSTOIEEE and NOCONVERTALLFLOATSTOIEEE as toggles in the parameter file to turn the conversion on for some of the files or tables and off for others. A CONVERTALLFLOATSTOIEEE parameter will be in affect until a NOCONVERTALLFLOATSTOIEE parameter is encountered and vice versa.
Note:
To use CONVERTALLFLOATSTOIEEE, the Extract and Replicat must be native objects; not TNS.
Default
NOCONVERTALLFLOATSTOIEE
Syntax
CONVERTALLFLOATSTOIEE
Example
EXTRACT EXTORD RMTHOST host01, MGRPORT 12345 CONVERTALLFLOATSTOIEEE TABLE $DATA01.SALES.ORDERS; NOCONVERTALLFLOATSTOIEEE TABLE $DATA03.SALES.CUSTOMER;