Initialization Parameters, 182 of 188


TIMED_STATISTICS

Parameter type: 

Boolean 

Parameter class: 

Dynamic. Scope = ALTER SYSTEM, ALTER SESSION. 

Default value: 

FALSE 

Range of values: 

TRUE | FALSE 

TIMED_STATISTICS specifies whether statistics related to time are collected or not. Appendix C, "Statistics Descriptions", indicates which statistics depend on the setting of this parameter.

  • TRUE: The statistics are collected and stored in trace files or displayed in the V$SESSTATS and V$SYSSTATS dynamic performance views.

  • FALSE: The value of all time-related statistics is set to zero. This setting lets Oracle avoid the overhead of requesting the time from the operating system. Normally, TIMED_STATISTICS should be FALSE.

 

On some systems with very fast timer access, Oracle might enable timing even if this parameter is set to FALSE. On these systems, setting the parameter to TRUE can sometimes produce more accurate statistics for long-running operations. 

See Also: Oracle8i Designing and Tuning for Performance for more information on setting this parameter and on performance diagnostic tools in general.  