7.7.5.4 DESCRIBE CELL
Purpose
The DESCRIBE CELL
command displays a list of attributes for the CELL
object type.
Syntax
DESCRIBE CELL
Usage Notes
The following list contains the attributes for the DESCRIBE CELL
command.
-
accessLevelPerm
: Specifies the access level at which the cell runs by default. Value is eitherremoteLoginEnabled
orremoteLoginDisabled
. -
accessLevelTemp
: Duration of time in which the access level is temporarily changed from the setting ofaccessLevelPerm
-
accountLockInDays
: Number of days after a password expires before a user account is locked. Available with Oracle Exadata System Software release 19.1.0 or later. -
bbuStatus
: Status of hard disk controller battery-backed unit (BBU) -
cellsrvStatus
: Status of Cell Server -
cellVersion
: Release number of the cell software columnarCachePersMode
: Controls the persistent columnar cache feature-
comment
: User-supplied text string -
cpuCount
: Number of CPUs on the cell -
dbPerfDataSuppress
: Specifies which databases should not have their statistics reported in Automatic Workload Repository (AWR) reports -
diagHistoryDays
: Number of days ADR files are retained. The default is 7 days. -
diagPackEmailAttach
: Whether a diagpack is included as an attachment in the alert email or not. The default istrue
. -
diagPackUploadEnabled
: Whether the auto diagpack upload feature is enabled or not. The default istrue
. -
doNotServiceLEDStatus
: Status of the cell DoNotService LED. The value can beon
oroff
. -
eighthRack
: Specifies whether Oracle Exadata Database Machine Eighth Rack configuration for storage cells is enabled or disabled -
emailFormat
: File format for email messages. The value can behtml
ortext
. -
emailSubscriber
: List of names that subscribe to the alert notifications -
events
: String for events++ that is passed to Cell Server for debugging and trace information purposes -
exacliEnabled
: Specifies whetherexacli
is enabled or disabled. The default value is true (enabled). -
fanCount
: Count of working fans and total fans, displayed as working/total -
fanStatus
: Status of the fan. The value can benormal
,warning
, orcritical
. -
flashCacheMode
: Setting for flash cache. The value can bewritethrough
orwriteback
. The default iswritethrough
. -
httpsAccess
: Control list of IP addresses for HTTPs port access to the Exadata RESTful Service. Available with Oracle Exadata System Software release 19.1.0 or later. -
id
: Global unique identifier (GUID) supplied by the hardware vendor -
interconnect[1-8]
: Interconnect1 to interconnect8 for the cell. For example:bondeth0
orbondib0
. -
interconnectCount
: Number of active InfiniBand network interconnects -
iormBoost
: Ratio of the cumulative number of positions in the I/O queue that were skipped because of IORM scheduling to the number of I/Os that where scheduled. This ratio is calculated by sampling the changes each minute in the two numbers. -
IOTimeoutThreshold
: Specifies the timeout threshold. If cell I/O takes longer than the defined threshold, then the I/O is canceled, and Oracle ASM redirects the I/O to another mirror copy of the data. -
ipaddress[1-8]
:ipaddress1
toipaddress8
for the cell -
kernelVersion
: Version of the host kernel software -
location
: Physical location of the cell hardware supplied by the user -
locatorLEDStatus
: Status of cell LOCATE LED. The value can beon
oroff
. mailServer
: Fully qualified domain name of the email relay server used to send alert notifications-
makeModel
: Make and model of the cell hardware supplied by the vendor -
memoryGB
: The memory in gigabytes for the cell -
metricCollection
: Indicator for whether Management Server performs metric collection. Values areTRUE
orFALSE
. If set toFALSE
, then all collection and alert mining is stopped. The default setting isTRUE
. -
metricHistoryDays
: Number of days that regular metric history files are retained. The default is 7 days. -
msStatus
: Status of Management Server -
name
: Unique name for the cell -
notificationMethod
: Notification method for alerts. The value should bemail
,snmp
,none
, or bothmail
andsnmp
. -
notificationPolicy
: Indicator for severity alerts to be sent to subscribers. The value fornotificationPolicy
should benone
or any combination ofcritical
,warning
, andclear
. -
offloadGroupEvents
: Used only under the guidance of Oracle Support -
pmemCacheMode
: PMEM cache mode.The default is
writethrough
. Commencing with Oracle Exadata System Software release 23.1.0,writethrough
is the only supported mode for PMEM cache. Previously,writeback
mode was available but was not generally recommended. -
powerCount
: Count of power supplies, displayed as working/total -
powerStatus
: Status of the power. The value can benormal
,warning
, orcritical
. -
pwdExpInDays
: The number of days before a user's password expires. Available with Oracle Exadata System Software release 19.1.0 or later. -
pwdExpWarnInDays
: The number of days before a user's password expires that a warning message is issued during login attempts. Available with Oracle Exadata System Software release 19.1.0 or later. -
rackName
: The name of the rack -
releaseImageStatus
: Indicator for knowing whether imaging is successful -
releaseTrackingBug
: Patch number for the cell software, such as 30441371 -
releaseVersion
: Release number for the cell software, such as 19.3.1.0.0.191018 -
remotePwdChangeAllowed
: Whether or not a user password can be changed remotely through REST services. Available with Oracle Exadata System Software release 19.1.0 or later. -
rescuePlan
: A list of commands that you can run after a server rescue to restore settings, such as IORM plans, thresholds, and notifications, to the last known values. -
rollbackVersion
: The inactive image version that the cell maintains. Ifpatchmgr rollback
is invoked for the cell, the value displayed byrollbackVersion
is the software version that will be reinstated. -
rpmVersion
: The RPM version of the cell -
rsStatus
: Status of Restart Server -
securityCert
: The certified identity of the cell. Either CA-certified identity or the default self-certified identity. -
siteName
: The site name for the cell smtpFrom
: User name that appears in theFrom:
header of the alert notificationssmtpFromAddr
: Email address that appears in theFrom:
header of the alert notifications. This email address is not authenticated with the email server.-
smtpPort
: Email server port used to send alert notifications -
smtpToAddr
: Address to which email is sent. It can be a comma-delimited list in quotation marks to allow multiple subscribers to alerts. -
smtpUseSSL
: Specification to use Secure Socket Layer (SSL) encryption for alert notifications. -
snmpSubscriber
: List of hosts that subscribe to the SNMP alert notifications -
snmpUser
: Defines the user who receives SNMP alerts -
status
: Status of the cell storageIndexPersMode
: Controls the persistent storage index feature-
syslogConf
: Designates syslog messages that should be forwarded to a specified management server. Uses the following syntax for the attribute, where selector is the message type, and node is the specified server:syslogconf = (selector @node' [, 'selector @node']... )
Both selector and node follow
syslog.conf
standard syntax rules. syslogFormat
: A string representing the format for syslog messages. Available with Oracle Exadata System Software release 19.1.0 or later.-
temperatureReading
: Current temperature (Celsius) of the cell obtained from the BMC -
temperatureStatus
: Status of the temperature. The value can benormal
,warning
, orcritical
. -
traceLevel
: The level for which trace messages are written. The default isFINE
. The value can be:-
A valid Java logging level
SEVERE
WARNING
INFO
CONFIG
FINE
FINER
FINEST
-
A valid Oracle Diagnostic Logging (ODL) logging level
INCIDENT_ERROR:1
ERROR:1
WARNING:1
NOTIFICATION:1
NOTIFICATION:16
TRACE:1
TRACE:16
TRACE:32
-
-
upTime
: Time (days, hours:minutes) since the system was restarted -
usbStatus
: Status of the USB device
Examples
The following example shows the DESCRIBE
command with the CELL
object.
Example 7-97 Describing the CELL Object
CellCLI> DESCRIBE CELL
name modifiable
accessLevelPerm modifiable
accessLevelTemp modifiable
accountLockInDays modifiable
bbuStatus
cellsrvStatus
cellVersion
comment modifiable
cpuCount
dbPerfDataSuppress modifiable
diagHistoryDays modifiable
diagPackEmailAttach modifiable
diagPackUploadEnabled modifiable
doNotServiceLEDStatus
eighthRack modifiable
emailFormat modifiable
emailSubscriber modifiable
events modifiable
exacliEnabled modifiable
fanCount
fanStatus
flashCacheMode modifiable
httpsAccess modifiable
id
interconnect1 modifiable
interconnect2 modifiable
interconnect3 modifiable
interconnect4 modifiable
interconnect5 modifiable
interconnect6 modifiable
interconnect7 modifiable
interconnect8 modifiable
interconnectCount
iormBoost
IOTimeoutThreshold modifiable
ipaddress1
ipaddress2
ipaddress3
ipaddress4
ipaddress5
ipaddress6
ipaddress7
ipaddress8
kernelVersion
location modifiable
locatorLEDStatus
mailServer modifiable
makeModel
memoryGB
metricCollection modifiable
metricHistoryDays modifiable
msStatus
notificationMethod modifiable
notificationPolicy modifiable
offloadGroupEvents modifiable
pmemCacheMode modifiable
powerCount
powerStatus
pwdExpInDays modifiable
pwdExpWarnInDays modifiable
rackName modifiable
releaseImageStatus
releaseTrackingBug
releaseVersion
remotePwdChangeAllowed modifiable
rescuePlan hidden
rollbackVersion
rpmVersion
rsStatus
securityCert modifiable
siteName modifiable
smtpFrom modifiable
smtpFromAddr modifiable
smtpPort modifiable
smtpToAddr modifiable
smtpUseSSL modifiable
snmpSubscriber modifiable
snmpUser modifiable
status
syslogConf modifiable
syslogFormat modifiable
temperatureReading
temperatureStatus
traceLevel modifiable
upTime
usbStatus
Related Topics
Parent topic: DESCRIBE