Siebel Service Handheld Guide > Deployment of Siebel Handheld > Process for Installing the Siebel Handheld Application >

Editing the Handheld Application Installation Configuration File


The Siebel Handheld application setup.ini file configures the Siebel Handheld Client application installer. Before you deploy a custom-configured Siebel Handheld application, you must update the parameters in the setup.ini file so that the correct values are written to the device registry before distributing the client installer to end users.

The setup.ini file resides in the Siebel Handheld application directory (for example, the Service Handheld directory) on the Siebel Handheld DVD-ROM. To modify this file, create a Siebel Handheld installation directory on the network, or create and duplicate a custom DVD-ROM for distribution to end users. This installation directory must include the same files and directory structure as the original DVD-ROM. Then, modify the setup.ini file in the custom installation directory.

NOTE:  If you wish to set up parameter values other than default values, add the parameter to the setup.ini file and add the proper values.

Table 15 lists the parameters that you may need to modify in the setup.ini file, their default value, and a description of the parameter.

Table 15.  Siebel Handheld setup.ini Parameters
Parameter
Default Value
Description

Version

7.7

Version of the desktop Siebel application against which the Siebel Handheld version synchronizes.

Application Title

SiebelService for CE

The Siebel Handheld application. This value must match the name of the application as it is specified in Siebel Tools.

ApplicationName

SiebelService for CE

The Siebel Handheld application. This value must match the name of the application as it is specified in Siebel Tools.

ApplicationSplashText

Service Handheld

The Siebel Handheld application name as shown on the splash screen.

MultiCurrency

True

Required for the application to handle multiple currencies.

SyncURL

http://Web Server Name or IP address/Virtual Directory Name

Required for Direct Server Sync. This value is entered in the registry on the handheld. See Changing the SyncURL on Siebel Handheld Devices for more information on this parameter.

[EndUserLocalization] Section

 

 

User DefinedLang

Y

 

LogUserDefinedLangErrors

N

 

[Printing] Section

 

See Print Configuration Settingsfor more information on the parameters used to configure printing.

[Backup] Section

 

Enables handheld database backups.

See Editing the Database Backup Parameters for more information on settings for the parameters in this section of the setup.ini file.

[ApplicationLocation] Section

 

Specifies where the Siebel Handheld application and database are installed.

See Setting up Siebel Handheld Application Installation on a CompactFlash Card for more information on the parameters in this section of the setup.ini file.

InternetOptionReceiveTimeout

600000

Length of time to receive data (except data extraction) from the server before the handheld client times out. This parameter only applies to synchronizations using Direct Server Sync.

In milliseconds. The default value, 600000, is 10 minutes.

InternetOptionSendTimeout

600000

Length of time to send data to the server in a single call the handheld client times out. This parameter only applies to synchronizations using Direct Server Sync.

In milliseconds. The default value, 600000, is 10 minutes.

InternetOptionDataExtractionTimeout

900000

Length of time to extract data from the server to the handheld device the handheld client times out. This parameter only applies to synchronizations using Direct Server Sync.

[Logging] Section

 

 

TXNErrorLevel

1

This level controls the extent of transaction error information received from the server

DefaultLogLevel

2

This is for logging messages

MaxLogFileSize

2000

This is for the maximum log file size in KB

MaxSavedLogFiles

3

Determines the number of log files to save.

Siebel Service Handheld Guide