BEA Logo BEA Tuxedo Release 8.0

  BEA Home  |  Events  |  Solutions  |  Partners  |  Products  |  Services  |  Download  |  Developer Center  |  WebSUPPORT

 

   Tuxedo Documentation   |   File Formats and Data Descriptions Reference   |   Local Topics   |   Previous Topic   |   Next Topic   |   Contents

 


factory_finder.ini

Name

factory_finder.ini—FactoryFinder domain configuration file

Description

factory_finder.ini is the FactoryFinder configuration file for domains. This text (ASCII) file is parsed by the TMFFNAME service when it is started as a Master NameManager. The file contains information used by NameManagers to control the import and the export of object references for factory objects with other domains. To use the information in the factory_finder.ini file, you must specify the factory_finder.ini file in the -f option of the TMFFNAME server process.

Definitions

A BEA Tuxedo system domain application is defined as the environment described in a single TUXCONFIG file. A BEA Tuxedo system application can communicate with another BEA Tuxedo system application or with another TP application via a domain gateway group. In "BEA Tuxedo system domain" terms, an application is the same as a TP domain.

A Remote Factory is a factory object that exists in a remote domain that is made available to the application through a BEA Tuxedo FactoryFinder.

A Local Factory is a factory object that exists in the local domain that is made available to remote domains through a BEA Tuxedo FactoryFinder.

File Format

The file is made up of two specification sections. Allowable section names are: DM_REMOTE_FACTORIES and DM_LOCAL_FACTORIES.

Note: If you use the TobjFactoryFinder interface, the factory_kind must be FactoryInterface.

The required parameter is:

DOMAINID = domain_id

This parameter specifies the identity of the remote domain in which the factory object is to be retrieved. The DOMAINID must not be greater than 32 octets in length. If the value is a string, it must be 32 characters or fewer (counting the trailing NULL). The value of domain_id can be a sequence of characters or a sequence of hexadecimal digits preceded by 0x.

The optional parameter is:

RNAME = string

This parameter specifies the name exported by remote domains. This value will be used by a remote domain to request this factory object. If this parameter is not specified, the remote factory object name is the same as the named specified in factory_id.factory_kind.

Multiple entries with the same name can be specified as long as the values associated with either the DOMAINID or RNAME parameter results in the identification of a unique factory object.

Examples

 