Table 28. Siebel Handheld Application setup.ini Parameters
|
|
|
Version |
8.0 |
Version of the desktop Siebel application against which the Siebel Handheld application version synchronizes. |
ApplicationName |
Siebel Pharma CE |
The Siebel Handheld application. This value must match the name of the Handheld application as it is specified in Siebel Tools. |
ApplicationSplashText |
Pharma CE Handheld |
The Siebel Handheld application name as shown on the splash screen. |
EnableRemote |
N |
Used for Integrated Sync. The default value is N. Valid values are Y = [Enable Remote Sync] check box is selected, N = [Enable Remote Sync] check box is unselected in the synchronization window of the Handheld application. |
MultiCurrency |
True |
Required for the Handheld application to handle multiple currencies. |
SyncURL |
http://Web Server Name or IP address/Virtual Directory Name |
Required for all synchronization methods. This value is entered in the registry for the Siebel Handheld application. NOTE: PPC 2002 and PPC 2003 do not have a hosts file similar to the Windows Operation System (for example, C:\WINNT\system32\drivers\etc\hosts.file ), where you can set up mappings for the IP address and host name.
For more information about this parameter, see Changing the SyncURL on Handheld Devices. |
[EndUserLocalization] Section |
|
|
User DefinedLang |
Y |
|
LogUserDefinedLangErrors |
N |
|
[Printing] Section |
(various) |
For more information about the parameters used to configure printing, see Print Configuration Settings. |
[Backup] Section |
(various) |
Enables Siebel Handheld application database backups. For more information about settings for the parameters in this section of the setup.ini file, see Enabling Siebel Handheld Application Database Backup. |
[ApplicationLocation] Section |
(various) |
Specifies where the Siebel Handheld application and database are installed. For more information about the parameters in this section of the setup.ini file, see Setting Up Siebel Handheld Application Installation on a CompactFlash Card. |
InternetOptionReceiveTimeout |
600000 |
Length of time to receive data or a response (except data extraction) from the server in the case of Direct Server Synchronization or the Laptop in the case of Companion Synchronization, before the Siebel Handheld application times out. The default value, 600000 milliseconds, is 10 minutes. |
InternetOptionSendTimeout |
600000 |
Length of time to send data to the server in the case of Direct Server Synchronization or to the Laptop in the case of Companion Synchronization, before the Siebel Handheld application times out. The default value, 600000 milliseconds, is 10 minutes. |
InternetOptionDataExtractionTimeout |
900000 |
Length of time to extract data from the server in the case of Direct Server Synchronization or from the Laptop in the case of Companion Synchronization (to the handheld device), before the Siebel Handheld application times out. The default value, 900000 milliseconds, is 15 minutes. |
RemoteTimeout |
1800000 |
Length of time for the handheld device Syncmanager process to wait for a remote synchronization to complete, before timing out. The default value, 1800000 milliseconds, is 30 minutes. NOTE: This parameter only applies to synchronizations using Companion Synchronization and when remote synchronization is enabled.
|
[Logging] Section |
|
|
TXNErrorLevel |
1 |
This level controls the extent of transaction error information received from the server. The default value is 1. Valid values are 0 = no log information, 1 = report txn errors in the Siebel Handheld Client log, txnerror.hh. A "Transaction Errors Reported" message appears during synchronization when txn errors occur. To view errors, double click the message. |
DefaultLogLevel |
2 |
The default value is 2. You can set the value to any of the following: -1 = NO LOGGING 0 = LOG_SYSTEM 1 = LOG_ERROR 2 = LOG_WARNING 3 = LOG_INFO, INCLUDING SQL TRACING 4 = LOG_DEBUG The log messages with level equal to or lower than the set value will be logged. For example, if the default log level is set to 2, the messages belonging to System, Error, and Warning log levels will be logged. If the DefaultLogLevel is -1, no logging will be provided. |
MaxLogFileSize |
2000 |
This is the maximum log file size in KB. If the program finds the size of the latest log file is greater than this value, a new log file must be used for logging. |
MaxSavedLogFiles |
3 |
Determines the number of log files to save on the device. It does not include the one currently used by the program. If the value is set to 2, then the valid log file names are siebel_log.txt, Siebel_log1.txt, and siebel_log2.txt. Siebel_log.txt is the current log file. Siebel_log1 is an older one and Siebel_log2 is the oldest. |
PressureThreshold |
29 |