A P P E N D I X  A

Sun Netra X4450 ILOM Reference Information

This appendix contains reference material about the Sun Netra X4450 server.

Topics include:


Components on the Sun Netra X4450 Server

TABLE A-1 shows the components on the Sun Netra X4450 server.


TABLE A-1   Sun Netra X4450 Components
Name Description
/SYS Host system
/SYS/ALARM Indicator module
/SYS/MB Motherboard
/SYS/BIOS BIOS
/SYS/CPLD NVRAM
/SYS/MB/MCH/Dxy DIMM, where y equals the channel and x equals the DIMM
/SYS/MB/NETx Network interface, where x equals the interface number
/SYS/PCI_MEZZ PCI mezzanine tray
/SYS/PDB Power distribution board
/SYS/PSx Power supply, where x equals the number of the drive
/SYS/SASBP Disk drive backplane/SAS card
/SYS/SP Service processor
/SYS/SP/NET0 Network interface (BMC controller)


Sensors on the Sun Netra X4450 Server

TABLE A-2 shows the sensors on your server.


TABLE A-2   Sun Netra X4450 Server Sensors
Type Name Description Unit of Measure or Value
Entity presence /SYS/MB/Px/PRSNT Motherboard, CPU, where x equals the number of the CPU Present or absent
  /SYS/SASBP/PRSNT Disk backplane (SAS controller) Present or absent
  /SYS/PSx/PRSNT Power supply, where x equals the number of the power supply Present or absent
  /SYS/HDDx/PRSNT Disk drive, where x equals the number of the drive Present or absent
  /SYS/PSx/I_IN Power supply input current, where x equals the number of the power supply Amps
  /SYS/PSx/I_OUT Power supply output current, where x equals the number of the power supply Amps
  /SYS/FT0/Fx/TACH System fan, where x equals the number of the fan RPM
  /SYS/FT1/Fx/TACH Hard drive fan, where x equals the number of the drive RPM
  /SYS/FT2/F0/TACH Power distribution board fan RPM
  /SYS/PS0/F0/TACH Power supply fan RPM
  /SYS/VPS Source output power Watts
  /SYS/PSx/INPUT_POWER Power supply input power, where x equals the number of the power supply Watts
  /SYS/PSx/OUTPUT_POWER Power supply output power, where x equals the number of the power supply Watts
Power supply /SYS/PSx/VINOK Power supply voltage OK, where x equals the number of the power supply Deasserted or asserted
  /SYS/PSx/PWROK Power supply power OK, where x equals the number of the power supply Deasserted or asserted
  /SYS/PSx/CUR_FAULT Power supply current fault, where x equals the number of the power supply Deasserted or asserted
  /SYS/PSx/VOLT_FAULT Power supply voltage fault, where x equals the number of the power supply Deasserted or asserted
  /SYS/PSx/FAN_FAULT Power supply fan fault, where x equals the number of the power supply Deasserted or asserted
  /SYS/PSx/TEMP_FAULT Power supply temperature fault, where x equals the number of the power supply Deasserted or asserted
Temperature /SYS/MB/T_AMB0 Motherboard ambient temperature 0 Degrees C
  /SYS/MB/T_AMB1 Motherboard ambient temperature 1 Degrees C
  /SYS/MB/T_AMB2 Motherboard ambient temperature 2 Degrees C
  /SYS/MB/T_AMB3 Motherboard ambient temperature 3 Degrees C
  /SYS/PSx/T_AMB Power supply ambient temperature, where x is the number of the power supply Degrees C
Voltage /SYS/ALARM/INPUT Alarm input state Deasserted or asserted
  /SYS/MB/Px/V_VCC CPU voltage, where x is the number of the CPU Volts
  /SYS/MB/V_+12V Motherboard +12V Volts
  /SYS/MB/V_VTT Motherboard VTT Volts
  /SYS/MB/V_+1V5 Motherboard +1.5V Volts
  /SYS/MB/V_+3V3 Motherboard +3.3V Volts
  /SYS/MB/V_+5 Motherboard +5V Volts
  /SYS/MB/V_NIC Motherboard NIC Volts
  /SYS/MB/V_+3V3STBY Motherboard +3.3V standby Volts
  /SYS/MB/V_+2V5STBY Motherboard +2.5V standby Volts
  /SYS/MB/V_+1V8 Motherboard +1.8V Volts
  /SYS/PDB/+5V0_POK Power distribution board +5V Deasserted or asserted
  /SYS/PSx/V_IN Power supply input voltage, where x equals the number of the power supply Volts
  /SYS/PSx/V_OUT Power supply output voltage, where x equals the number of the power supply Volts


Indicators on the Sun Netra X4450 Server

TABLE A-3 shows the indicators on your server.


TABLE A-3   Sun Netra X4450 Indicators
Type Name
System /SYS/LOCATE
  /SYS/OK
  /SYS/SERVICE
Alarm /SYS/ALARM/CRITICAL
  /SYS/ALARM/MAJOR
  /SYS/ALARM/MINOR
  /SYS/ALARM/USER
Disk drive /SYS/HDDx/SERVICE, where x equals the number of the drive
  /SYS/HDDx/OK2RM, where x equals the number of the drive
CPU /SYS/MB/Px/SERVICE, where x equals the number of the drive
DIMM /SYS/MB/MCH/Dxy/SERVICE, where x equals the number of the channel and y equals the number of the DIMM


SNMP Traps on the Sun Netra X4450 Server

This section contains the SNMP traps from SUN-HW-TRAP-MIB on the Sun Netra X4450 server.


TABLE A-4   Traps for All Hot Pluggable Components
Trap
sunHwTrapFruInserted
sunHwTrapFruRemoved


TABLE A-5   Traps for BIOS Reported Errors
Trap
sunHwTrapPreOSError


TABLE A-6   Traps Corresponding to Sensors and Components in the SDR
Trap Sensor or Component
sunHwTrapComponentError /SYS/ALARM/INPUT

/SYS/NMIBTN-HIDDEN

/SYS/PDB/+5V0_POK

ACPI

sunHwTrapComponentOk /SYS/ALARM/INPUT

/SYS/PDB/+5V0_POK

sunHwTrapFanSpeedCritThresholdDeasserted /SYS/PS0/F0/TACH

/SYS/PS1/F0/TACH

sunHwTrapFanSpeedCritThresholdExceeded /SYS/PSx/F0/TACH, where x equals the number of the power supply
sunHwTrapFanSpeedFatalThresholdDeasserted /SYS/FTx/Fy/TACH

/SYS/PSz/F0/TACH

where x equals the number of the fan tray, y equals the number of the fan, and z equals the number of the power supply

sunHwTrapFanSpeedFatalThresholdExceeded /SYS/FTx/Fy/TACH

/SYS/PSz/F0/TACH

where x equals the number of the fan tray, y equals the number of the fan, and z equals the number of the power supply

sunHwTrapPowerSupplyError /SYS/PSx/CUR_FAULT

/SYS/PSx/FAN_FAULT

/SYS/PSx/PWROK

/SYS/PSx/TEMP_FAULT

/SYS/PSx/VINOK

/SYS/PSx/VOLT_FAULT

where x equals the number of power supply

sunHwTrapPowerSupplyOk /SYS/PSx/CUR_FAULT

/SYS/PSx/FAN_FAULT

/SYS/PSx/PWROK

/SYS/PSx/TEMP_FAULT

/SYS/PSx/VINOK

/SYS/PSx/VOLT_FAULT

where x equals the number of power supply

sunHwTrapSensorCritThresholdDeasserted /SYS/VPS
sunHwTrapSensorCritThresholdExceeded /SYS/VPS
sunHwTrapSensorFatalThresholdDeasserted /SYS/VPS
sunHwTrapSensorFatalThresholdExceeded /SYS/VPS
sunHwTrapSensorNonCritThresholdExceeded /SYS/VPS
sunHwTrapSensorThresholdOk /SYS/VPS
sunHwTrapTempCritThresholdDeasserted /SYS/MB/T_AMB0

/SYS/MB/T_AMB1

/SYS/MB/T_AMB2

/SYS/MB/T_AMB3

sunHwTrapTempCritThresholdExceeded /SYS/MB/T_AMB0

/SYS/MB/T_AMB1

/SYS/MB/T_AMB2

/SYS/MB/T_AMB3

sunHwTrapTempNonCritThresholdExceeded /SYS/MB/T_AMB0

/SYS/MB/T_AMB1

/SYS/MB/T_AMB2

/SYS/MB/T_AMB3

sunHwTrapTempOk /SYS/MB/T_AMB0

/SYS/MB/T_AMB1

/SYS/MB/T_AMB2

/SYS/MB/T_AMB3

sunHwTrapVoltageCritThresholdDeasserted /SYS/MB/V_+12V

/SYS/MB/V_+1V5

/SYS/MB/V_+1V8

/SYS/MB/V_+2V5STBY

/SYS/MB/V_+3V3

/SYS/MB/V_+3V3STBY

/SYS/MB/V_+5V

/SYS/MB/V_NIC

/SYS/MB/V_VTT

/SYS/PSx/V_OUT

where x equals the number of the power supply

sunHwTrapVoltageCritThresholdExceeded /SYS/MB/V_+12V

/SYS/MB/V_+1V5

/SYS/MB/V_+1V8

/SYS/MB/V_+2V5STBY

/SYS/MB/V_+3V3

/SYS/MB/V_+3V3STBY

/SYS/MB/V_+5V

/SYS/MB/V_NIC

/SYS/MB/V_VTT

/SYS/PSx/V_OUT

where x equals the number of the power supply

sunHwTrapVoltageFatalThresholdDeasserted /SYS/MB/V_+12V

/SYS/MB/V_+1V5

/SYS/MB/V_+1V8

/SYS/MB/V_+2V5STBY

/SYS/MB/V_+3V3

/SYS/MB/V_+3V3STBY

/SYS/MB/V_+5V

/SYS/MB/V_NIC

/SYS/MB/V_VTT

/SYS/PSx/V_OUT

where x equals the number of the power supply

sunHwTrapVoltageFatalThresholdExceeded /SYS/MB/V_+12V

/SYS/MB/V_+1V5

/SYS/MB/V_+1V8

/SYS/MB/V_+2V5STBY

/SYS/MB/V_+3V3

/SYS/MB/V_+3V3STBY

/SYS/MB/V_+5V

/SYS/MB/V_NIC

/SYS/MB/V_VTT

/SYS/PSx/V_OUT

where x equals the number of the power supply

sunHwTrapVoltageNonCritThresholdExceeded /SYS/PSx/V_OUT

where x equals the number of the power supply

sunHwTrapVoltageOk /SYS/PSx/V_OUT

where x equals the number of the power supply