A P P E N D I X  A

Product Specifications

This appendix lists the specifications for the Ultra 40 and Ultra 40 M2 workstations. Topics include:


A.1 Physical Specifications

TABLE A-1 lists the physical specifications of the Sun Ultra 40 and Ultra 40 M2 workstation.


TABLE A-1 Sun Ultra 40 and Ultra 40 M2 Workstation Physical Specifications

Length

Width

Height

Weight

22.4 in.
(569 mm)

8.1 in.
(205 mm)

17.5 in. (445 mm)

49.6 lbs
(22.5 kgs)


If you replace the workstation enclosure, allow adequate airflow from front to rear. The enclosure interior dimensions should be no less than those in TABLE A-2.


TABLE A-2 Enclosure Interior Dimensions for the Sun Ultra 40 and Ultra 40 M2 Workstation.

Length

Width

Height

22 in.
(558 mm)

8.1 in.
(205 mm)

17.5 in. (445 mm)



A.2 Electrical Specifications

TABLE A-1 lists electrical specifications for the Sun Ultra 40 and Ultra 40 M2 workstation.


TABLE A-3 Sun Ultra 40 and Ultra 40 M2 Workstation Electrical Specifications

Specification

Value

Voltage

100/ 110-127/200-240 VAC

Current

13/12/7 Amps

Wattage

1000 Watts (maximum)

Frequency

50-60 Hz



A.3 Acoustic Specifications

TABLE A-4 lists acoustic specifications for the Sun Ultra 40 and Ultra 40 M2 workstation.



Note - Acoustic specifications are configuration dependent.



TABLE A-4 Sun Ultra 40 and Ultra 40 M2 Workstation Acoustic Specifications

Specification

System State

Value

Sound power

Operating with HDD

4.9 Bels (approximate)

 

 

Idle

4.7 Bels (approximate)

Acoustics

Operating with HDD or ODD

Lpam = 34 dba

 

 

Idle

Lpam = 33 dba



A.4 Environmental Requirements

TABLE A-5 lists environmental requirements for the Sun Ultra 40 and Ultra 40 M2 workstation.


TABLE A-5 Sun Ultra 40 and Ultra 40 M2 Workstation Environmental Requirements

Specification

Value

Temperature

41˚ to 95˚ F (5˚ to 35˚ C) operating

-40˚ to 149˚ F (-40˚ to 65˚ C) nonoperating

 

Humidity

7 - 93% RH (noncondensing) operating

93% RH (noncondensing) nonoperating

Pressure

9.43 PSI (65 KPa), 95˚ F (35˚ C) operating

3.62 PSI (25 KPa), 77˚ F (25˚ C) nonoperating



A.5 Shock and Vibration Specifications

TABLE A-6 lists vibration specifications for the Sun Ultra 40 Workstation.


TABLE A-6 Sun Ultra 40 and Ultra 40 M2 Workstation Shock and Vibration Specifications

Constraint

Operating

Nonoperating

Shock

4.5 G, 11 msec, half sine

33 G, 11 msec, sine

Vibration

0.25 G^2/Hz random,
5 to 500 Hz (0.70 Grms)

1.2 G^2/Hz random,
5 to 500 Hz (1.11 Grms)

Drop

N/A

1.97 in. (50 mm)