Sun Oracle Logo


Sun Management Center 4.0 Version 7 Add-On Software Release Notes For SPARC Enterprise, Sun Fire, Sun Blade, Sun Ultra, Netra, Sun Netra, and SPARC T3 Systems

Release Notes For SPARC Enterprise, Sun Fire, Sun Blade, Sun Ultra, Netra, Sun Netra, and SPARC T3 Systems, Netra SPARC T3-1 Server, and Netra SPARC T4-1 Server

E23101-02



Feedback Contents

Sun Management Center 4.0 Version 7 Add-On Software Release Notes

What’s New in This Release

Related Documentation

Supported Software Environments

Supported Systems

Recommended Patches

Obtaining the Add-On Software

Installation

procedure iconsmall spaceUninstall Previous Versions of the Add-On Software

procedure iconsmall spaceInstall Sun Management Center 4.0 Software

procedure iconsmall spaceInstall the Sun Management Center 4.0 Version 7 Add-On Software

Issues and Workarounds

Physical Components Fan Table is Empty on Netra SPARC T3-1 Servers (CR 7019466)

Error Message: Unable to Launch the Application due to Unavailable Sunconnection.sun.com URL (CR 7029129)

Netra SPARC T3-1 and Netra SPARC T4-1 Servers Indicator Table Reporting Incorrect Status for HDD Hot-plugged Event (CR 7020337)

Netra SPARC T3-1 and Netra SPARC T4-1 Servers Voltage/Current Sensors Reporting Incorrect Operational Status Following a Power Supply Fan Fault (CR 7020508)

Netra SPARC T3-1 and Netra SPARC T4-1 Servers, Additional Information Field Reports Incorrect Fatal Threshold When the Power Supply is Removed (CR 7029653)

Alarm Tab in Details Window Is Not in Sync With Agent (CR 6548517)

Console Falsely Displays Description Information (CR 6585734)

XAUI Cards Are Not Listed in All Applicable Tables (CR 6604020 and 6971521)

Console Does Not Display SAN (MPXIO) Disks on Certain Systems (CR 6655853)

Processors Table Does Not Appear in Web Console (CR 6662409)

System Table and Media Devices Table Show the Wrong Number of HDD (CR 6665401)

Sun Management Center Displays All Disks as Not Configured With Logical Domains Set Up (CR 6666611)

Sun Management Center Updates Spare/No-intr Processors Incorrectly on Logical Domains System (CR 6730867)

ILOM Should Convert PS Input Voltage Correctly Before Sending It (CR 6735038)

Environmental Sensor Faults Not Reported Correctly at Threshold Values (CR 6738914)

Processors Table Changes With Configuring Primary Domain (CR 6751418)

Network Interfaces Table Does Not Update When NIC Is Hot-Plugged (CR 6756972)

Information In Media Devices Table Is Incomplete for all T3 Series Servers and Netra SPARC T4-1 Server (CR 6963594)

ILOM Sends Truncated Serial Numbers for FRUs (CR 6967351)

DIMM Serial Numbers Returned Incorrectly (CR 6981291)

Feedback