C H A P T E R  4

Connecting Your Array

This chapter describes procedures for cabling a Sun StorEdge 3510 FC array or Sun StorEdge 3511 SATA array, and for connecting an array to power and to network devices.

The following topics are covered in this chapter:

Before you connect a Sun StorEdge 3510 FC array or Sun StorEdge 3511 SATA array to the network, position the array in the rack, cabinet, or other location where it will be used.



caution icon

Caution - When positioning the array, do not block the air vents at the front or back of the unit. Follow all safety precautions specified in the Sun StorEdge 3000 Family Safety, Regulatory, and Compliance Manual.





caution icon

Caution - When you power off an array, wait five seconds before you power it back on. If you power the array off and on too quickly, unexpected results can occur. See Section 4.15, Powering Off the Array.




4.1 Converting Your Front Bezel Locks So the Keys Cannot Be Removed

The bezel on your array has two locks whose keys can be removed when the locks are in either the locked or open position. It is possible to reconfigure the locks so that the keys cannot be removed.

  FIGURE 4-1 Front Bezel and Front Bezel Locks of an Array

This figure displays the front bezel and the bezel locks on the right and left sides of the bezel.

To change the locks so the keys cannot be removed, perform the following steps.

1. Remove the bezel by gently pivoting the swing arms out of their ear sockets.

See Section 7.5.1, Removing the Front Bezel and Ear Caps for step-by-step instructions on how to remove the bezel.

2. Make sure the key is in the locked position, with the pawl extending horizontally past the edge of the bezel.

3. Hold the key in place and use a 3/8-inch (12-mm) nut driver to remove the locking nut that holds the pawl in place, as shown in the first panel of FIGURE 4-2.



caution icon

Caution - Be sure to hold the key in place. Otherwise there is a risk of breaking the small tab on the lock that serves as a stop.



4. Lift the pawl off the threaded part of the lock body, as shown in the second panel of FIGURE 4-2.

  FIGURE 4-2 Sequence of Steps to Change Front Bezel Locks So Keys Cannot Be Removed

Figure showing the five steps required to change front bezel locks so the keys cannot be removed.

5. Set the pawl aside, face up, so that you can remember its orientation when you replace it.

6. Use the key to turn the lock 180 degrees, as shown in the third panel of FIGURE 4-2.

7. Replace the pawl in the same orientation as before, as shown in the fourth panel of FIGURE 4-2.

8. Hold the key in place and use the nut driver to refasten the locking nut that holds the pawl in place, as shown in the fifth panel of FIGURE 4-2. Be careful not to cross-thread the nut.



caution icon

Caution - Be sure to hold the key in place. Otherwise there is a risk of breaking the small tab on the lock that serves as a stop.



9. Replace the bezel.



Note - To convert your bezel locks so that the keys can be removed, repeat this procedure.




4.2 RAID Array Connections

Management is in-band through fibre host connections and out-of-band through the serial port and Ethernet port on the back of each controller.

4.2.1 Sun StorEdge 3510 FC Array Connections

FIGURE 4-3 identifies the hardware connections on the back of a dual-controller Sun StorEdge 3510 FC array

  FIGURE 4-3 Hardware Connections on the Back of a Dual-Controller Sun StorEdge 3510 FC Array

Figure shows the back panel of a dual-controller Sun StorEdge 3510 FC array with the hardware connections identified.

4.2.2 Sun StorEdge 3511 SATA Array Connections

FIGURE 4-4 identifies the hardware connections on the back of a dual-controller Sun StorEdge 3511 SATA array.

  FIGURE 4-4 Hardware Connections on the Back of a Dual-Controller Sun StorEdge 3511 SATA Array

Figure shows the back panel of a dual-controller Sun StorEdge 3511 SATA array with the hardware connections identified.


4.3 Connecting the Chassis to AC Power Outlets

When you connect the AC power cords, install the two provided cord locks at the same time. The AC cord locks are used to securely fasten the AC cable connectors.



caution icon

Caution - If the array is connected to AC power sources not within the designated 90-135 or 180-264 VAC range, the unit might be damaged.





Note - To ensure power redundancy, be sure to connect the two power supply modules to two separate circuits (for example, one commercial circuit and one UPS).



To connect the AC power cords, perform the following procedure.

1. Use a Phillips screwdriver to remove the screw and cylindrical standoff from one of the two provided cord locks.

Set them aside for reassembly later.

2. Slide the cord lock over the AC power connector.

See FIGURE 4-5.

3. Hold the cylindrical standoff between the two screw holes on the flanges of the cord lock.

4. Insert the screw into the first screw hole, through the standoff, and then into the threaded screw hole on the other flange.

5. Tighten the screw with a screwdriver until the flanges bottom out on the cylindrical standoff.

6. Push the power cord into the power supply receptacle until it is firmly seated.

7. Push the green ejector handle forward until it is seated against the power supply.

8. Turn the thumbscrew of the green ejector handle clockwise until it is finger-tight to secure the handle and the cord lock.



Note - To ensure that a thumbscrew is finger-tight, tighten it with a screwdriver and then loosen the thumbscrew counterclockwise a quarter turn.



9. Repeat Step 1 through Step 8 for the second cord lock and second power cable.

  FIGURE 4-5 Connecting the Chassis to AC Power

Figure shows the sequence of steps to connect a chassis to AC power.


4.4 Connecting the Chassis to DC Power Outlets



Note - The Sun StorEdge 3511 SATA array can only be ordered in an AC configuration. However, DC power supplies can be ordered in an x-option kit, and a Sun StorEdge 3511 SATA array can be reconfigured using the DC power supplies. Refer to the Sun StorEdge 3000 Family FRU Installation Guide for a procedure for removing and replacing power supplies.



Two DC power cords are packaged with each DC array. To connect the DC power cords, perform the following procedure.

1. Check the DC cable part number and wire labels carefully before connecting the cable to the source.

TABLE 4-1 DC Cable Wiring for Cable 35-00000156 or 35-00000306

Pin Number

Voltage

Color

A3

L+

Red

A2

GND (Chassis Ground)

Green/Yellow

A1

L-

White


2. Connect a DC power cable to the first power supply and to a power outlet.



Note - Use only the DC power cables provided with the array.





caution icon

Caution - If the array is connected to DC power sources not within the designated -48V DC (-36 VDC to -72 VDC) range, the unit might be damaged.





Note - To ensure power redundancy, be sure to connect the two power supply modules to two separate circuits (for example, one commercial circuit and one UPS).





Note - To extend the length of the DC power cable as needed, strip the last 1/4 inch of the cable, insert the stripped end into a provided Panduit tube, and crimp the tube.



3. Tighten the cable-locking screws to attach the cable securely to the power supply power outlet.

4. Connect the second power cable to the second power supply and to a second power outlet. Tighten the cable-locking screws.

If one power supply fails, the second power supply automatically takes the full load.


4.5 Cabling to Expansion Units

You can connect an unused expansion unit to an active RAID controller at any time without stopping I/O. However, precautions must be taken if the expansion unit has previously been used. See Section 4.12, Connecting an Expansion Unit to an Existing RAID Array for more information.



caution icon

Caution - When connecting expansion units to a RAID array, always connect channel 2 of the RAID array to the A channel of the expansion units, and connect channel 3 of the RAID array to the B channel of the expansion units. Otherwise, unexpected behavior might occur.



Several cabling configurations are possible, each with its own advantages and disadvantages. Refer to the Sun StorEdge 3000 Family Best Practices Manual for your array for more information about the suitability of various configurations for various application requirements, as well as for information about high-capacity configurations.

The maximum number of expansion units attached to a RAID array are:

These configurations are described in the Sun StorEdge 3000 Family Best Practices Manual for your array.

The examples in FIGURE 4-6 and FIGURE 4-7 show RAID arrays connected to two expansion units. Connections to expansion units are designed to keep all A drive ports on the same loop and all B drive ports on the same loop.



caution icon

Caution - To avoid drive assignment conflicts, make sure that each connected array and expansion unit uses a different loop ID, as described in Section 4.6, Setting Loop IDs on Expansion Units.



In the RAID array, two of the unused SFP host ports can be used to provide redundant pathing to the two servers, and the remaining unused SFP host ports can be connected to two more servers in a redundant configuration.

Similarly, you can connect expansion units to other channels (which are separate from channels 2 and 3) if you configure them as drive channels. For details, refer to the Sun StorEdge 3000 Family RAID Firmware User's Guide.

  FIGURE 4-6 Sun StorEdge 3510 FC Array Attached to Two Hosts and Two Expansion Units

Figure shows cabling for a Sun StorEdge 3510 FC Array and two expansion units.

 

  FIGURE 4-7 Sun StorEdge 3511 SATA Array Attached to Two Hosts and Two Expansion Units

Figure shows cabling for a Sun StorEdge 3511 SATA Array and two expansion units.


4.6 Setting Loop IDs on Expansion Units

When an expansion unit is attached to a RAID array, unique, hard-assigned loop IDs are assigned to each expansion unit drive. A loop ID is the decimal version of an arbitrated loop physical address (AL_PA). The lowest number loop ID is the lowest priority address on the loop.

On the left front side of an expansion unit, an ID switch is used to set the loop IDs for the disk drives to a different range of values so that the same IDs are not repeated by RAID units and expansion units on the same loop.

The default ID switch setting for RAID arrays is 0. The default range of available drive IDs for RAID arrays is 0 to 11 for 12 drives (the IDs 12-15 are ignored). The default ID switch setting for expansion units and JBODs is 1.

Ensure that the loop IDs of expansion units do not duplicate the loop IDs of other connected expansion units or RAID arrays.

The ID switch offers eight ID ranges. Each range contains 16 IDs (the last four IDs in each range are ignored). These ranges are shown in TABLE 4-2.

TABLE 4-2 ID Switch Settings for Expansion Units

ID Switch Setting

Range of IDs

0

0-15

1

16-31

2

32-47

3

48-63

4

64-79

5

80-95

6

96-111

7

112-125


For an example of properly configured loop IDs, consider the configurations shown in FIGURE 4-6 and FIGURE 4-7. You must make sure the RAID array and each of the two expansion units have been assigned different loop IDs. Set the loop ID switches so that the RAID array is assigned loop ID 0, expansion unit 1 has loop ID 1, and expansion unit 2 has loop ID 2. The range of IDs assigned to the drives is shown in TABLE 4-3.

TABLE 4-3 Sample Array and Expansion Units With Different Loop IDs and Drive IDs

Fibre Channel Device

Loop ID Switch Setting

Range of Drive IDs

RAID array

0

0-15

Expansion unit 1

1

16-31

Expansion unit 2

2

32-47


Setting the loop ID on an array or expansion unit requires dropping the front bezel out of the way and removing the small vertical plastic cap on the left side of the bezel that covers the left rackmount tab. Rackmount tabs are also referred to as "ears."

  FIGURE 4-8 Front Bezel and Front Bezel Locks of an Array

This figure displays the front bezel, bezel locks, and plastic ear cap covering the FC loop ID switch.

1. Use the provided key to unlock both bezel locks.

2. Grasp the front bezel cover on both sides and pull it forward and then down.

3. Remove the plastic cap from the left ear of the array.

a. Squeeze both sides of the cap at the top and the bottom.

b. Turn the cap toward the center of the array until it disengages and pull it free.



caution icon

Caution - To avoid damage to the cap, do not pull the cap forward directly or pull from only its top or bottom.



The ID switch is exposed when you remove the plastic cap.

  FIGURE 4-9 ID Switch Located on the Left Front Side of Arrays and Expansion Units

Figure shows the ID Switch located on the left front side of arrays and expansion units.

4. Press the upper or lower switch button to change the ID number so that each connected RAID array and expansion unit uses a different loop ID.



caution icon

Caution - The loop ID should only be changed while the expansion unit is powered off or not in use. After changing the loop ID, a power cycle is required to make the ID switch change take effect. Failure to cycle the power following a loop ID change can lead to unexpected results.



5. Prepare the plastic left ear cap for replacement by aligning the inside round notches of the cap with the round cylindrical posts (ball studs) on the ear.

6. Push the top and bottom of the ear cap onto the ear, pressing in on the top side toward the center of the array first.

7. Continue pushing the top and bottom of the ear cap onto the ear, pressing on the side toward the outside of the array.

Do not use force when placing a cap on an ear.

8. Lift the bezel into position and press it onto the front of the chassis until it is flush with the front.

9. Use the key to lock both bezel locks.


4.7 Powering On and Checking LEDs

Perform the initial check of the array according to the following procedure.

1. Connect two AC or DC power cables to the power and fan modules on the back of the array.

2. Power on the array by turning on each power switch.

See Section 4.14, Power-On Sequence for the power-up sequence to use when operating RAID arrays and expansion units. See Section B.7, Connecting Sun StorEdge 3510 FC JBOD Arrays for the power-up sequence to use when operating standalone Sun StorEdge 3510 FC JBODs directly attached to hosts.

3. Check for the following LED activity:

All front-panel LEDs turn solid green to indicate good operation.

  FIGURE 4-10 Front Panel of the Sun StorEdge 3510 FC Array and Sun StorEdge 3511 SATA Array, With LEDs Displayed

Figure shows the front panel of the Sun StorEdge 3510 FC array and Sun StorEdge 3511 SATA array, with LEDs displayed.

See Chapter 6 for more information about your array's LEDs.


4.8 Reviewing Channels, Ports, and SFPs

I/O controller modules have ports that accept small form-factor pluggable (SFP) transceivers. These ports are labeled FC0 through FC5, to indicate channels 0 through 5. Default configurations do not include an SFP connector in every SFP port. To add or change SFP connectors, see to Section 4.8.4, Changing Your SFP Configuration.

The channels and associated ports for Sun StorEdge 3510 FC arrays and Sun StorEdge 3511 SATA arrays are summarized in TABLE 4-4.

TABLE 4-4 Number of Ports in Sun StorEdge 3510 FC Arrays and Sun StorEdge 3511 SATA Arrays

Item

Sun StorEdge 3510 FC Array

Sun StorEdge 3511 SATA Array

Total number of ports

6

8

Channel 0

1 FC0 host or drive port;
default: host port

2 FC0 dedicated host ports[1]

Channel 1

1 FC1 host or drive port;
default: host port

2 FC1 dedicated host ports3

Channel 2[2]

1 FC2 dedicated drive port

1 FC2 dedicated drive port

Channel 3[3]

1 FC3 dedicated drive port

1 FC3 dedicated drive port

Channel 4

1 FC4 host or drive port;
default: host port

1 FC4 host or drive port;
default: host port

Channel 5

1 FC5 host or drive port;
default: host port

1 FC5 host or drive port;
default: host port


4.8.1 Drive Port Connectivity in a Dual-Controller Array

Drive channels connect to the internal drives in the array and can also connect to drives in external expansion units. The key difference between the Sun StorEdge 3510 FC array and Sun StorEdge 3511 SATA array drive channels is the assignment of two ports for each channel:

4.8.1.1 Sun StorEdge 3510 FC Array Drive Ports

Configured for redundancy, each controller in a dual-controller RAID array has two adjacent dedicated drive channels on one loop to load-balance I/O operations (see FIGURE 4-11). Each drive channel has two SFP ports that can be connected to expansion units. Drive channels 2 and 3 access all the disk drives and are interconnected to load-balance I/O operations.

  FIGURE 4-11 Dedicated Drive Channels 2 on the Upper Controller and 3 on the Lower Controller in a Dual-Controller Sun StorEdge 3510 FC Array

Figure shows the back of a Sun StorEdge 3510 FC Array with each controller configured with two drive channel ports connected in a single loop.

The I/O controller module in slot A (the upper slot) houses drive channel 2, which connects to the 12 internal disk drives through their A ports. The I/O controller module in slot B (the lower slot) houses drive channel 3, which connects to the 12 internal disk drives through their B ports.

4.8.1.2 Sun StorEdge 3511 SATA Array Drive Ports

Drive channels 2 and 3 are dedicated drive channels. Configured for redundancy, each drive channel of the top I/O controller module shares a loop with the matching drive channel on the bottom I/O controller module. For example, drive channel 2 of the top I/O controller module shares the same loop as channel 2 on the bottom I/O controller module (see FIGURE 4-12). Each drive channel has two SFP ports that can be connected to expansion units. Drive channels 2 and 3 access all the disk drives using internal FC-SATA routing technology and are interconnected to load-balance I/O operations. Each drive channel has an upper and lower port.

  FIGURE 4-12 Dedicated Drive Channels 2 and 3 (on Both Controllers) in a Dual-Controller Sun StorEdge 3511 SATA Array

Figure shows the back of a Sun StorEdge 3511 SATA Array with each controller configured with two drive channel ports connected in a single loop

4.8.2 Host Port Connectivity in a Dual-Controller Array

Host channels connect to host computers either directly or through storage switches or other devices. In a default dual-controller RAID configuration, each controller has four host channels, channels 0, 1, 4, and 5. Port bypass circuits connect each pair of host SFP ports on a host channel; as a result, each host channel accesses both controllers.

The main differences between Sun StorEdge 3510 FC arrays and Sun StorEdge 3511 SATA arrays are the number of host ports and the supported speed for each port (see TABLE 4-5).

TABLE 4-5 Number of Host Ports and Supported Host Port Speeds

Data Transfer Speed

Sun StorEdge 3510 FC Array

Sun StorEdge 3511 SATA Array

1 Gbit or 2 Gbit

Maximum of 4 host ports per I/O controller module

Maximum of 4 host ports (FC 0 and FC 1) per I/O controller module

2 Gbit only

N/A

Maximum of 2 host ports (FC 4 and FC 5) per I/O controller module


4.8.2.1 Sun StorEdge 3510 FC Array Host Ports

In a default dual-controller RAID configuration, each controller has four host ports. Each port connects to one host channel (see FIGURE 4-13). All four host channels support 1-Gbit or 2-Gbit data transfer speeds. Each host channel has an upper port and a lower port.

  FIGURE 4-13 Host Channels on a Dual-Controller Sun StorEdge 3510 FC Array

Figure shows the back of a Sun StorEdge 3510 FC Array with each controller in the default configuration with each host channel looped between the two controllers.

4.8.2.2 Sun StorEdge 3511 SATA Array Host Ports

In a default dual-controller RAID configuration, each controller has six host ports, as shown in FIGURE 4-14:

Channels 0 and 1 support 1-Gbit or 2-Gbit data transfer speeds. Channels 4 and 5 support 2-Gbit data transfer speeds only.

If a fabric switch is connected to one port of channel 0 or channel 1, no connections can be made with the other three ports of that channel. If channel 0 (FC 0) is connected to a fabric switch, for example, the second port for channel 0 on that controller, and both ports on a redundant controller cannot be used. Similarly, if channel 1 (FC 1) is connected to a fabric switch, the second port on that controller and the two FC 1 ports on a redundant controller cannot be used.

Two hosts can be directly connected to either channel 0 (ports FC 0) or channel 1 (ports FC 1), but in that configuration, host filters are required if you want to control host access to storage. Each host channel has an upper port and a lower port.

  FIGURE 4-14 Host Channels on a Dual-Controller Sun StorEdge 3511 SATA Array

Figure shows the back of a Sun StorEdge 3511 SATA array with each controller in the default configuration with each host channel looped between the two controllers.

4.8.3 Default SFP Placement

Default configurations do not include an SFP connector in every SFP port. You might want to add or rearrange SFPs, depending on the configuration mode (loop or point-to-point), the number of planned host connections, the necessary number of redundant connections to hosts, and the number of expansion units needed.

The supported SFP is a single-port, optical SFP transceiver for multimode (short wave) or single-mode (long wave) use. It is compatible with the Small Form Factor Pluggable Multi-Sourcing Agreement (MSA, Sep. 2000), and 1x and 2x Fiber Channel. The optical connector used is the low-profile LC connector.

SFPs are Sun field-replaceable units (FRUs) and can be ordered from Sun Microsystems. These SFPs have been selected and tested to provide the necessary reliability and performance. SFPs from other vendors are not supported.

To review various configuration options, see the discussions following Section 5.1, Summary of Array Configuration. Refer also to the configuration options presented in the Sun StorEdge 3000 Family Best Practices Manual for your array.

In dual-controller arrays, SFPs are initially plugged into one of each pair of host and drive ports. The default port connections are:

This configuration provides connections to all six host channels as well as to both drive channels (see FIGURE 4-15 and FIGURE 4-16).

  FIGURE 4-15 Default Dual-Controller Sun StorEdge 3510 FC Array SFP Placement

Figure shows the Sun StorEdge 3510 FC array default dual-controller SFP placement.

  FIGURE 4-16 Default Dual-Controller Sun StorEdge 3511 SATA Array SFP Placement

Figure shows the Sun StorEdge 3511 SATA array default dual-controller SFP placement.

In the default single-controller array, SFPs are initially plugged into the following ports:

No SFPs are plugged into the drive channels. This configuration is appropriate for connecting to up to four hosts or fibre switches, with no connection to expansion units (see FIGURE 4-17 and FIGURE 4-18).

  FIGURE 4-17 Sun StorEdge 3510 FC Array Default Single Controller SFP Placement

Figure shows the Sun StorEdge 3510 FC array default single-controller SFP placement.

  FIGURE 4-18 Sun StorEdge 3511 SATA Array Default Single-Controller SFP Placement

Figure shows the Sun StorEdge 3511 SATA array default single-controller SFP placement.

In a default Sun StorEdge 3510 FC expansion unit, SFPs are initially plugged into the left-most port of the upper I/O expansion module and right-most port of the lower I/O expansion module (see FIGURE 4-19).

  FIGURE 4-19 Sun StorEdge 3510 FC JBOD/Expansion Unit Default SFP Placement

Figure shows the default SFP placement for Sun StorEdge 3510 FC expansion units and JBODs.

In a default Sun StorEdge 3511 SATA expansion unit, SFPs are initially plugged into the left-most Loop A port in the upper I/O expansion module and in the left-most Loop B port in the lower I/O expansion module (FIGURE 4-20).

  FIGURE 4-20 Sun StorEdge 3511 SATA Expansion Unit Default SFP Placement

Figure shows the default Sun StorEdge 3511 SATA expansion unit SFP placement.

4.8.4 Changing Your SFP Configuration

Sun StorEdge 3510 FC arrays and Sun StorEdge 3511 SATA arrays use SFP connectors to attach to hosts and expansion units. These SFP connectors resemble the one shown in FIGURE 4-21, with a single connector at the end that plugs into an SFP port on the array or expansion unit chassis, and a duplex jack into which you insert a cable to make the connection.

  FIGURE 4-21 Typical SFP Connector Used to Connect Cables to Chassis SFP Ports

Figure shows a typical SFP connector used to connect cables to array chassis ports.


4.9 Establishing Communications With An Array

Before you can configure an array, you must establish one or more communication links between at least one host and an array. You can use any combination of the array's RS-232 COM (serial) port, the Ethernet port, and the in-band data connection between the host and the array.

See Section 4.9.2, Configuring the RS-232 Serial Port Connection for more information. For pinout information, see Appendix D.

When you connect via the serial port, you immediately access the controller firmware application, a management program embedded in the firmware.

You can use this IP address to monitor and manage the array's firmware through telnet sessions. See Section 4.10, Setting Up Out-of-Band Management Over Ethernet for information about setting up a telnet session. The out-of-band management tools are:



Note - You can install the latest Sun StorEdge 3000 Family CLI or Configuration Service software from the CD for your product or download the software from the Sun Download Center. See your product release notes for details.





Note - By default, the CLI and the Sun StorEdge Configuration console automatically access in-band all arrays connected to the host server where the software is installed.



See Section 4.9.3, Manually Setting a Static IP Address for information.

4.9.1 Determining the Default IP Address

When the array is first powered up, the default IP address setting uses the IP address assigned by a DHCP server.



Note - If you do not use a DHCP server with the array, you will not have an IP address and will need to use the serial port connection to create an IP address. See Section 4.9.2, Configuring the RS-232 Serial Port Connection.



If the RAID array is connected to a network with an active DHCP server, you can determine the IP address assigned to the array in several ways:

When you connect via the serial port, you immediately access the controller firmware application, a management program embedded in the firmware.

If the RAID controller is not on a network connected to an active DHCP server, an IP address of 0.0.0.0 is displayed. Refer to the Sun StorEdge 3000 Family CLI User's Guide for more information.

Event messages sent as SNMP traps to the email address you specify also contain the IP address of the array from which they are sent. Refer to the "Configuration Parameters" chapter in the Sun StorEdge 3000 Family RAID Firmware User's Guide for more information.

Once you have determined the RAID controller's IP address using one of these methods, you can establish a telnet session to that IP address.



caution icon

Caution - However, because of the dynamic nature of DHCP-assigned IP addresses, the RAID array's IP address might change in the event of a controller reset, a network outage, or if the DHCP server is rebooted. If this happens, telnet sessions to the previous IP address can no longer communicate with the array, and it is necessary to use one of the methods described above to determine the new IP address.



If you do not have an active DHCP server on the same network as the RAID array, or if you prefer to have a static IP address, use the procedures in Section 4.9.3, Manually Setting a Static IP Address.

4.9.2 Configuring the RS-232 Serial Port Connection

The RS-232 COM (serial) port on either controller module can be used to configure and monitor the RAID array using the controller firmware. It can be connected to a VT100 terminal, terminal emulation program, terminal server, or the serial port of a server.



Note - When you connect through a serial port connection, you might need to refresh the screen to display the RAID firmware Main Menu properly. Press Ctrl-L to refresh the screen.



1. Use a null modem serial cable to connect the COM port of the RAID array to the serial port on a host workstation.

A null modem serial cable is included in your package.

2. Set the serial port parameters on the workstation as follows:

If you need information on how to set up a Solaris tip session or how to set up serial port parameters on a specific operating system, see Section E.2, Using the tip Command for Local Access to the Array.

3. Access the array through the COM serial port and select the VT100 terminal emulation to access the RAID firmware Main Menu.

4. Check the DHCP IP address and confirm that it is valid.

From the RAID firmware Main Menu choose "Configuration Parameters right arrow Communication Parameters right arrow Internet Protocol (TCP/IP)."

If the RAID controller is not on a network connected to an active DHCP server, "DHCP Client" is displayed rather than a DHCP-assigned IP address. Refer to the "Configuration Parameters" chapter in the Sun StorEdge 3000 Family RAID Firmware User's Guide for more information.

5. If you need to reset the IP address or make a static IP address, refer to Section 4.9.3, Manually Setting a Static IP Address.

6. Configure the array.

4.9.3 Manually Setting a Static IP Address

You can manually set an array's IP address using the controller's firmware by typing values for the IP address, the subnet mask, and IP address of the gateway. If your network uses a Reverse Address Resolution Protocol (RARP) server or a Dynamic Host Configuration Protocol (DHCP) server to automatically configure IP information for devices on the network, you can specify the appropriate protocol instead of typing the information manually.



Note - If you assign an IP address to an array to manage it out-of-band, for security reasons consider using an IP address on a private network rather than a publicly routable network. Using the controller firmware to set a password for the controller limits unauthorized access to the array. Changing the firmware's Network Protocol Support settings can provide further security by disabling the ability to remotely connect to the array using individual protocols such as HTTP, HTTPS, telnet, FTP, and SSH. Refer to the "Communication Parameters" section of the Sun StorEdge 3000 Family RAID Firmware User's Guide for more information.



To set the IP address, subnet mask, and gateway address of the RAID controller, perform the following steps.

1. Access the array through the COM port on the I/O controller module or through a telnet session to the existing IP address.

2. From the RAID firmware Main Menu, choose "view and edit Configuration parameters right arrow Communication Parameters right arrow Internet Protocol (TCP/IP)."

3. Select the chip hardware address and MAC address that is displayed.

4. Choose "Set IP Address right arrow Address."

5. Type the desired IP address, subnet mask (if it is not automatically supplied), and gateway address, choosing each menu option in turn, backspacing over any existing entries.

If your network sets IP addresses using a RARP server and you prefer using it to using a static IP address, type RARP rather than an IP address and do not type a subnet mask or gateway address. If your network sets IP addresses using a DHCP server and you prefer using it to using a static IP address, type DHCP rather than an IP address and do not type a subnet mask or gateway address.

6. Press Esc to continue.

A confirmation prompt is displayed.

Change/Set IP Address ?

7. Choose Yes to continue.



Note - You must reset the controller for the configuration to take effect.



You are prompted to reset the controller.

8. Choose Yes to reset the controller.

The controller takes a few minutes to reset.


4.10 Setting Up Out-of-Band Management Over Ethernet

The controller Ethernet port offers interactive out-of-band management through the following interfaces:

Using an Ethernet connection, you can configure and monitor RAID arrays and expansion units remotely by using the telnet command to access the firmware application on the array and by using Sun StorEdge Configuration Service or the Sun StorEdge CLI software.



Note - If you assign an IP address to an array to manage it out-of-band, for security reasons consider using an IP address on a private network rather than a publicly routable network. Using the controller firmware to set a password for the controller limits unauthorized access to the array. Changing the firmware's Network Protocol Support settings can provide further security by disabling the ability to remotely connect to the array using individual protocols such as HTTP, HTTPS, telnet, FTP, and SSH. Refer to the "Communication Parameters" section of the Sun StorEdge 3000 Family RAID Firmware User's Guide for more information.



1. To access the RAID array over an Ethernet connection, first connect the RAID array's Ethernet port on each controller to the network.



Note - Sun StorEdge 3000 family arrays require at least CAT-5 Ethernet cable.





Note - In a dual-controller RAID array, be sure to connect both Ethernet ports to the network. This provides failover if one controller fails.



2. Establish the IP address of the RAID array, as described in Section 4.9, Establishing Communications With An Array.

3. To use the firmware application program from the host server, connect to the IP address of the RAID array controller with the following command:

# telnet IP-address



Note - Alternatively, you can use the Solaris operating system tip command or a terminal emulation program to access the firmware application program. See Section 4.9.2, Configuring the RS-232 Serial Port Connection for more information.



4. Press Ctrl-L to refresh the screen and view the RAID firmware Main Menu.



Note - If you reset the controller during a telnet session, you are disconnected from the RAID array. Use the telnet command to login to the array again.



To connect Sun StorEdge Configuration Service (on a host server) to a RAID array that has an IP address, refer to the out-of-band management instructions in the Sun StorEdge 3000 Family Configuration Service User's Guide.

The same document's "Email and SNMP" appendix provides information about configuring Sun StorEdge Configuration Service to use Simple Network Management Protocol (SNMP) traps and Management Information Bases (MIBs) to provide information to other out-of-band enterprise management software. The "Monitoring the Array" chapter explains the use of Sun StorEdge Configuration Service agents to redirect event messages into host system logs.

You can also enable the controller firmware to send event messages using SNMP. Refer to the "Configuration Parameters" chapter in the Sun StorEdge 3000 Family RAID Firmware User's Guide for more information.


4.11 Scaling a Sun StorEdge Fibre Channel Array Into a High-Capacity Configuration



Note - High-capacity Sun StorEdge 3510 FC array and Sun StorEdge 3511 SATA array configurations are supported, with certain limitations. A Sun StorEdge 3510 FC array with more than two expansion units is a high-capacity configuration. A Sun StorEdge 3511 SATA array with one expansion unit is a high-capacity configuration.



Sun StorEdge 3510 FC arrays typically allow the connection of up to two expansion units to support a maximum of 36 disks. However, you can create larger configurations that support as many as eight expansion units and up to 108 disks if you use the guidelines in this section. You can also create larger configurations of Sun StorEdge 3511 SATA arrays that support from one to five expansion units and up to 72 disks.

Carefully consider the following limitations of special high-capacity configurations. Using multiple Sun StorEdge Fibre Channel arrays connected to the same SAN normally provides significantly better performance than one high-capacity configuration.

Refer to the Sun StorEdge 3000 Family Best Practices Manual for more information and sample cabling diagrams.



Note - Large configurations might require the use of one or more optional extended-length cables, part number X9732A. Other items might also be required. Refer to the Sun StorEdge 3000 Family FRU Installation Guide for information about supported cables and other field-replaceable items.




4.12 Connecting an Expansion Unit to an Existing RAID Array

You can connect an unused expansion unit to an active RAID controller at any time without stopping I/O, as long as you make sure that a unique loop ID has been set for the expansion unit. However, precautions must be taken if the expansion unit has previously been used. If possible, ensure that there are no logical drives or logical volumes configured on expansion units before they are attached to an active RAID controller. Then, after connecting and powering up the expansion unit, reset the controller so that it recognizes any configured drives on the expansion unit.

To connect an expansion unit to a configured RAID array, perform the following steps.

1. Ensure that there are no logical drives or logical volumes configured on any previously used expansion units you want to connect to a RAID controller.

2. Stop I/O and shut down the controller to ensure that all data in the cache is written to disk.

For details on shutting down the controller, see Section 4.15, Powering Off the Array.

3. Verify that the loop ID of the expansion unit is set to a different ID than the RAID unit and any expansion units already attached.

For details on loop IDs, see Section 4.6, Setting Loop IDs on Expansion Units.

4. Physically cable the new expansion unit to the array using a valid cabling configuration.

Refer to the Sun StorEdge 3000 Family Best Practices Manual for your array for more information on expansion unit cabling configurations.

5. Power on the expansion units.

For details on the power-on sequence, see Section 4.14, Power-On Sequence.

6. Power on the RAID array.

7. Verify the SES/PLD (programmable logic device) version of the expansion unit and the RAID array.

To review the version information, using the Sun StorEdge CLI, type show ses. Or, using Sun StorEdge Configuration Service, open the View Enclosure window.

8. If the SES/PLD version is not the same for the RAID array and the expansion unit, download the latest SES/PLD firmware from SunSolve Online, located at:

http://sunsolve.sun.com


4.13 Connecting Arrays to Hosts

In a default array configuration, channels 0, 1, 4, and 5 are host channels, so you can directly connect an array to four host computers. SFP connectors are plugged into channels 0 and 4 on the upper controller and channels 1 and 5 on the lower controller for this purpose.

You can connect two additional host computers to channels 0 and 1 of a Sun StorEdge 3511 SATA array. To support six host computers, however, you need to insert SFPs in the four unpopulated host ports. Except for some clustering configurations, when you connect two hosts to channel 0 or channel 1 on a Sun StorEdge 3511 SATA array, you must use host filtering if you want to control host access in this configuration. Refer to the user documentation for your clustering software to determine whether the clustering software can manage host access in this configuration.

If you want to connect a Sun StorEdge 3510 FC array to more than four host computers, or connect a Sun StorEdge 3511 SATA array to more than six host computers, without changing the default configuration, you can connect these four host channels to ports on storage switches in a storage area network (SAN) configuration.

When a fabric switch is connected to one port of channel 0 or channel 1 of a Sun StorEdge 3511 SATA array, no connections can be made with the other three ports of that channel. If channel 0 (port FC0) is connected to a fabric switch, for example, the second port of channel 0 on that controller and the FC0 ports on a redundant controller cannot be used.



Note - The connection of a Sun StorEdge 3510 FC array or Sun StorEdge 3511 SATA array to Fibre Channel HBAs that use different speeds (1 Gbit and 2 Gbit) on the same channel is not supported. You can, however, mix 1-Gbit and 2-Gbit Fibre Channel HBAs on different channels. This limitation is due to the design of Sun StorEdge Fibre Channel array port bypass circuitry and the inability of Fibre Channel to support auto-negotiation in a multi-drop loop configuration.



Use fiber-optic cables to connect host channels to Fibre Channel HBAs on your host computers or to other devices such as storage switches.

1. Connect a fiber-optic cable to an HBA or FC port on each host or storage switch you want to connect to the array.

2. Connect the SFP connector at the other end of each of these fiber-optic cables to host channel SFP connectors on the back of the array.

If there is no SFP connector in the port you want to use, first insert an SFP connector into the port as described in Section 4.8.4, Changing Your SFP Configuration.


4.14 Power-On Sequence

Power on the equipment in the following order so the host computer discovers all connected arrays:

1. Expansion units

2. RAID controllers

3. Host computers

If an array is connected to a host using a serial port connection and powered on, the host terminal window displays a series of messages, as shown in the following example.

3510         Disk Array is installed with 1024MBytes SDRAM
Total channels: 6
Channel: 0 is a host channel, id: 40
Channel: 1 is a host channel, id: 41
Channel: 2 is a drive channel, id: 14, 15
Channel: 3 is a drive channel, id: 14, 15
Channel: 4 is a host channel, id: 70
Channel: 5 is a host channel, id: 71
Scanning channels. Please wait a few moments!
Preparing to restore saved persistent reservations. Type 'skip' to skip:

Do not use the skip option shown at the bottom of the example. This option is reserved for support personnel performing testing.


4.15 Powering Off the Array

You might need to power off the array (both power supplies) if you relocate the array or perform certain maintenance procedures with associated servers. Always shut down the array's controller before powering off the array.



caution icon

Caution - If controllers are not shut down from the firmware application or the Sun StorEdge CLI before an array is powered off, data that is written to cache and that has not been completely written to the disks will be lost.



To power off an array, perform the following steps.

1. Stop all I/O activity to the array.

2. Shut down the controller with one of the following commands:

These commands first halt all I/O activity, and then write the contents of cache to the drives.

3. Power off both power supply/fan modules.

See Section 4.14, Power-On Sequence for information about turning the array back on.

 

 


1 (TableFootnote) Only one host port connection per channel is allowed when connecting to a fabric switch.
2 (TableFootnote) Channel 2 drive ports connect to drive loop A ports on expansion units.
3 (TableFootnote) Channel 3 drive ports connect to drive loop B ports on expansion units.