JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Blade Storage Module M2 Product Documentation
search filter icon
search icon

Document Information

Preface

Product Information Web Site

Related Books

About This Documentation (PDF and HTML)

Documentation Comments

Change History

Hardware Installation

Overview of the Sun Blade Storage Module M2

System Requirements

Installing the Storage Module Into the Chassis

Storage Module Indicators

Assigning and Managing Storage

Product Notes

Overview of the Sun Blade Storage Module M2 Product Notes

Supported Firmware, Hardware and Software

Hardware Issues

Solaris Operating System Issues

Linux Operating System Issues

Administration

Assigning Storage to Hosts

Managing Storage

Performing Maintenance and Hot Plug Actions

Importing Existing Virtual Drives to a Replacement REM

Storage Module Sensors and Indicators

Troubleshooting

Viewing the CMM ILOM Event Log

Sun Blade Zone Manager Issues

Sun Blade Zone Manager Not Ready

Missing SAS-2 Components Error

Server Module Not SAS-2 Capable Error

Newly Inserted NEM is Not Discovered

Storage Module Issues

Storage Module Becomes Inaccessible at Host and ILOM /CH/BLx/fault_state is "Faulted"

Storage Module Becomes Inaccessible at Host and ILOM /CH/BLx/STATE is "Degraded"

Storage Module Fault LED is On

The Storage Module Powers Off

NEM Issues

SAS Path Disappears and ILOM /CH/NEMx/fault_state is "Faulted"

NEM Fault LED is On

NEM STATE (/CH/NEMx/STATE) is Not "Running"

NEM /CH/NEMx/OK Indicator is in Standby Blink

Service

Introduction to the Sun Blade Storage Module M2

Maintaining the Sun Blade Storage Module M2

Diagnosing Storage Module Faults

Specifications

Index

Missing SAS–2 Components Error

The chassis SAS-2 fabric is made of interconnected SAS-2 components (REMs, NEMs and storage modules). If a SAS-1 component is in place of a required SAS-2 component, the fabric itself will be incomplete and will display an error when you attempt to assign storage module resources from the CMM ILOM.

What to look for:

The following table provides examples of how the web interface and CLI might look like when the SAS-2 fabric is missing required components.

CMM ILOM
If SAS-2 Components are Missing from the Fabric
Web interface
In CMM->Storage->Zoning.image:Graphic showing Zoning Manager with Missing SAS-2 Components error.
CLI
-> ls

/STORAGE/sas_zoning
   Targets:
                  <---No targets are listed.
   Commands:
       cd
       set
       show 

Things to check:

An example of a complete chassis SAS-2 fabric looks like the following (note that SAS-1 components are automatically excluded):

image:Graphic showing access to SAS-2 domain.

A supported SAS-2 chassis fabric must have the following chassis components:

Actions to perform: