C H A P T E R  4

Sensors and Indicators

This chapter describes the sensors and indicators that can be accessed through the ILOM.

Sensors report physical information about the server, including voltages, temperatures, fan speeds, and installation and removal of components. Indicators report important server conditions.

All sensors and indicators are IPMI-compliant.

The following sections describe the sensors and indicators that ILOM monitors forthe Sun Blade X6275 Server Module.

Temperature and Power Sensors

Fan Failure Sensors

Chassis Fan Speed Sensors

Entity Presence Sensors

NEM and Blade Presence Sensors

Voltage Sensors

Indicators

Temperature and Power Sensors

These sensors report on the temperature sensors and the power consumption.


TABLE 4-3 Temperature and Power Sensors

Name

Sensor Type

Description

/SYS/MB/T_AMB_FRONT

Temperature

24.000 degrees C

/SYS/MB/T_AMB_REAR

Temperature

55.000 degrees C

/SYS/HOT

Temperature

State Deasserted

/SYS/VPS

System power unit (watts)

102.000 Watts


Fan Failure Sensors

These sensors assert predictive failure when a fan is expected to fail. Normally, they should read “Predictive Failure Deasserted.”


TABLE 4-4 Fan Failure Sensors

Name

Sensor Type

Description

/SYS/FM0/ERR

Fan

Predictive Failure Asserted

/SYS/FM1/ERR

Fan

Predictive Failure Deasserted

/SYS/FM2/ERR

Fan

Predictive Failure Deasserted

/SYS/FM3/ERR

Fan

Predictive Failure Asserted

/SYS/FM4/ERR

Fan

Predictive Failure Asserted

/SYS/FM5/ERR

Fan

Predictive Failure Deasserted


Chassis Fan Speed Sensors

These sensors indicate the speed of the chassis fans. The chassis fans are divided into eight modules (FM0 through FM7) with two fans each (F0 and F1).


TABLE 4-5 Chassis Fan Speed Measurements

Name

Sensor Type

Description

/SYS/FM0/F0/TACH

Fan

5400.000 RPM

/SYS/FM0/F1/TACH

Fan

5300.000 RPM

/SYS/FM1/F0/TACH

Fan

5300.000 RPM

/SYS/FM1/F1/TACH

Fan

5400.000 RPM

/SYS/FM2/F0/TACH

Fan

5300.000 RPM

/SYS/FM2/F1/TACH

Fan

5400.000 RPM

/SYS/FM3/F0/TACH

Fan

5400.000 RPM

/SYS/FM3/F1/TACH

Fan

5400.000 RPM

/SYS/FM4/F0/TACH

Fan

5300.000 RPM

/SYS/FM4/F1/TACH

Fan

5300.000 RPM

/SYS/FM5/F0/TACH

Fan

5300.000 RPM

/SYS/FM5/F1/TACH

Fan

5400.000 RPM


Entity Presence Sensors

These sensors report the presence or absence of system components.

NEM and Blade Presence Sensors

These sensors indicate whether there are NEMs in NEM slots 0 and 1, and whether any blades are in slots 0 through 11.



Note - In ILOM 3.0 the blades are as follows: Sun Blade 6000 is from BL0-BL9. Sun Blade 6048 is from BL0-BL11.



TABLE 4-7 NEM and Blade Presence

Name

Type

Description

/SYS/NEM0/PRSNT

Entity Presence

Present

/SYS/NEM1/PRSNT

Entity Presence

Present

/SYS/NEM0/ERR

OEM

Predictive Failure Deasserted

/SYS/NEM1/ERR

OEM

Predictive Failure Deasserted

/SYS/NEM0/STATE

Module

Running

/SYS/BL0/PRSNT

Entity Presence

Present

/SYS/BL0/ERR

OEM

Predictive Failure Asserted

/SYS/BL0/STATE

Module

Not Readable

/SYS/BL1/PRSNT

Entity Presence

Absent

/SYS/BL1/ERR

OEM

Predictive Failure Deasserted

/SYS/BL1/STATE

Module

Not Readable

/SYS/BL2/PRSNT

Entity Presence

Present

/SYS/BL2/ERR

OEM

Predictive Failure Deasserted

/SYS/BL2/STATE

Module

Not Readable

/SYS/BL3/PRSNT

Entity Presence

Present

/SYS/BL3/ERR

OEM

Predictive Failure Deasserted

/SYS/BL3/STATE

Module

Not Readable

/SYS/BL4/PRSNT

Entity Presence

Absent

/SYS/BL4/ERR

OEM

Predictive Failure Deasserted

/SYS/BL4/STATE

Module

Not Readable

/SYS/BL5/PRSNT

Entity Presence

Absent

/SYS/BL5/ERR

OEM

Predictive Failure Deasserted

/SYS/BL5/STATE

Module

Not Readable

/SYS/BL6/PRSNT

Entity Presence

Present

/SYS/BL6/ERR

OEM

Predictive Failure Deasserted

/SYS/BL6/STATE

Module

Not Readable

/SYS/BL7/PRSNT

Entity Presence

Absent

/SYS/BL7/ERR

OEM

Predictive Failure Deasserted

/SYS/BL7/STATE

Module

Not Readable

/SYS/BL8/PRSNT

Entity Presence

Absent

/SYS/BL8/ERR

OEM

Predictive Failure Deasserted

/SYS/BL8/STATE

Module

Not Readable

/SYS/BL9/PRSNT

Entity Presence

Absent

/SYS/BL10/PRSNT

Entity Presence

Absent

/SYS/BL11/PRSNT

Entity Presence

Absent


Voltage Sensors

These readings are asserted when thevoltage is OK and deasserted when the designated power supply generates a fault.

 

TABLE 4-8 Voltage

Name

Type

Description

/SYS/PS0/S0/V_IN_ERR

Voltage

Predictive Failure Deasserted

/SYS/PS0/S0/V_OUT_OK

Voltage

State Asserted

/SYS/PS0/S1/V_IN_ERR

Voltage

Predictive Failure Deasserted

/SYS/PS0/S1/V_OUT_OK

Voltage

State Asserted

/SYS/PS1/S0/V_IN_ERR

Voltage

Predictive Failure Deasserted

/SYS/PS1/S0/V_OUT_OK

Voltage

State Asserted

/SYS/PS1/S1/V_IN_ERR

Voltage

Predictive Failure Deasserted

/SYS/PS1/S1/V_OUT_OK

Voltage

State Asserted



Indicators

These report the state of the system indicators, including LEDs.

See the Sun Blade X6275 Installation Guide for descriptions of the LEDs and indicators.


TABLE 4-9 Indicators

Path

Indicator

Description

/SYS/OK

Green OK LED

Slow Blink

/SYS/OK2RM

Blue OK to Remove LED

Off

/SYS/SERVICE

Amber Service LED

Off

/SYS/LOCATE

White Locate LED

Off

/SYS/MB/P0/SERVICE

CPU error condition

Off

SYS/MB/P0/D0/SERVICE

DIMM error condition

Off

/SYS/MB/P0/D1/SERVICE

DIMM error condition

Off

/SYS/MB/P0/D2/SERVICE

DIMM error condition

Off

/SYS/MB/P0/D3/SERVICE

DIMM error condition

Off

/SYS/MB/P0/D4/SERVICE

DIMM error condition

Off

/SYS/MB/P0/D5/SERVICE

DIMM error condition

Off