Sun Fire X4170 M2 Server Service Manual
Service Manual
E22369-02
Contents |
1. Sun Fire X4170 M2 Server Overview
1.3 Server Front Panel Features
1.4 Server Back Panel Features
1.5 Server Status Indicators and LEDs
1.5.1 Server General Status Indicators
1.5.3 Storage and Boot Drive LEDs
1.5.5.3 Fault Remind Super Capacitor Power LED
2. Preparing to Service the System
2.3 Obtaining the Chassis Serial Number
2.4 Powering On and Off the Server
2.4.3 Power Off the Server Using the ILOM SP Command-Line Interface
2.5.1 BIOS Booting and Setup Considerations
2.5.1.1 Default BIOS Power-On Self-Test (POST) Events
2.5.1.2 BIOS POST F1 and F2 Errors
2.5.1.3 How BIOS POST Memory Testing Works
2.5.1.4 Ethernet Port Device and Driver Naming
2.5.1.5 Ethernet Port Booting Priority
2.5.2 BIOS Setup Utility Menus
2.5.3 BIOS Setup Utility Hot Keys
2.5.4 Accessing the BIOS Setup Utility Menus
2.5.4.1 Access BIOS Setup Utility Menus
2.5.5 Configuring Support for TPM
2.5.5.1 Configure TPM Support in BIOS
2.5.6 Configuring SP LAN Settings
2.5.6.1 Configure LAN Settings for SP
2.5.6.2 Viewing or Setting the ILOM SP IP Address Using the BIOS Setup Utility
2.5.7 Configuring Option ROM Settings in BIOS
2.5.7.1 Enable or Disable Option ROM Settings
2.5.8 Updating the BIOS Firmware
2.6 Extending the Server to the Maintenance Position
2.6.1 Extend Server to the Maintenance Position
2.7 Removing the Server From the Rack
2.7.1 Remove Server From the Rack
2.8 Using Server Filler Panels
2.8.2 Filler Panel Removal and Installation
2.9 Performing Electrostatic Discharge and Antistatic Prevention Measures
2.9.1 Electrostatic Discharge Safety Measures
2.9.1.1 Using an Antistatic Wrist Strap
2.9.1.2 Using an Antistatic Mat
2.9.2 Using ESD Handling Precautions
3. Servicing Customer-Replaceable Devices
3.1 Hot-Pluggable Versus Hot-Swappable Devices
3.2.1 Server Storage Drive Locations
3.2.2 Storage Drive Status LED Reference
3.3.2 Detecting Fan Module Failure
3.4.1 Detecting Power Supply Failure
3.4.2 Power Supply LED Reference
4. Servicing Motherboard Components
4.1 Motherboard Component Locations
4.2.1 DIMM and CPU Physical Layout
4.2.3 DIMM Rank Classification Labels
4.2.4 Locations of Faulty DIMMs Using ILOM Versus BIOS
4.2.5 Inconsistencies Between DIMM Fault LEDs and the BIOS Mapping of Faulty DIMMs
4.2.6 Remove Faulty DDR3 DIMMs
4.2.8 Error Correction and Parity
4.4.2 PCIe Card Configuration Guidelines
4.6.2.2 Upgrade Server to Two CPUs
4.8 Resetting Passwords and Clearing CMOS NVRAM
4.8.2 Reset the BIOS Password and Clear the CMOS NVRAM Using the CLR CMOS Button
5. Servicing Infrastructure Components
5.1 Infrastructure Component Locations
5.2 Servicing the DVD/USB Module
5.4 Servicing the Storage Drive Cage
5.4.1 Remove Storage Drive Cage
5.4.2 Install Storage Drive Cage
5.5 Servicing the Disk backplane
5.6 Servicing the Front Control Panel Light Pipe Assembly
5.6.1 Remove Front Control Panel Light Pipe Assembly
5.6.2 Install Front Control Panel Light Pipe Assembly
5.7 Servicing the Power Distribution Board
5.7.1 Remove Power Distribution Board
5.7.2 Install Power Distribution Board
5.8 Servicing the Paddle Board
5.9.1 Remove Storage Drive Cables From a SAS Configuration
5.9.2 Install Storage Drive Cables in a SAS Configuration
5.9.3 Remove Storage Drive Cables in a SATA Configuration
5.9.4 Install Storage Drive Cables in a SATA Configuration
5.9.5 Change Storage Drive Cables From SAS to SATA Configuration
5.9.6 Change Storage Drive Cables From SATA to SAS
5.9.8 Install Fan Board Cables
5.9.9 Remove Power Distribution Board Cable
5.9.10 Install Power Distribution Board Cable
6. Returning the Server to Operation
6.2 Reinstalling the Server in the Rack
6.2.1 Reinstall Server in Rack
6.3 Returning the Server to the Normal Rack Position
6.3.1 Return the Server to the Normal Rack Position
7. Troubleshooting the Server and Restoring ILOM Defaults
7.1 Troubleshooting the Server
7.1.2 Diagnostic Tool Documentation
7.2 Using the Preboot Menu Utility
7.2.1 Accessing the Preboot Menu
7.2.1.1 Prerequisites for Accessing the Preboot Menu
7.2.1.2 Access the Preboot Menu
7.2.1.3 Edit Preboot Menu for Remote Serial Access
7.2.1.4 Edit Mode Settings in Preboot Menu
7.2.2 Restoring ILOM to Default Settings
7.2.2.1 Resetting ILOM Configuration Using the Preboot Menu
7.2.3 Restoring ILOM Access to the Serial Console
7.2.3.1 Restore Access to the Serial Console Using the Preboot Menu
7.2.4 Restoring the SP Firmware Image
7.2.4.1 Prerequisite for Restoring SP Firmware Using Preboot Menu
7.2.4.2 Restore the SP Firmware Image Using the Preboot Menu
7.2.5 Preboot Menu Command Summary
A.1 Serial Management Port Connector
A.2 Network Management Port Connector
A.5 Gigabit Ethernet Connectors
B. Sun Fire X4170 M2 Server Illustrated Parts Breakdown
C.1 BIOS Setup Screens Overview
C.2 BIOS Setup Utility Menu Screens
C.2.2 BIOS Advanced Menu Screens
C.2.5 BIOS Security Menu Screen
C.2.6 BIOS Chipset Menu Screens
Copyright © 2011, Oracle and/or its affiliates. All rights reserved.