Exit Print View

Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for Sun Blade T6340 Server Modules

Get PDF Book Print View
 

Document Information

Using This Documentation

Related Documentation

Documentation, Support, and Training

Documentation Feedback

Understanding ILOM for the Sun Blade T6340 Server Module

ILOM Overview

Chassis Monitoring Module Features

Updating the System Firmware

Resetting the Password to the Factory Default

Managing the Host

Resetting the Host

Managing Host Boot Mode

Viewing and Configuring Host Control Information

Managing Host Diagnostics and POST

Managing System User Interactions

Managing the Service Processor

Storing Customer Information

Changing Service Processor Settings to Factory Defaults

Display Console History (CLI)

Change Console Escape Characters (CLI)

Changing Configuration Policy Settings

Managing Power Usage and Monitoring Power Consumption

Managing Network Access

Managing SSH Server Settings

Monitoring Active System Faults

Managing Devices

Managing Virtual Keyswitch Settings

Using the Remote Console

Hardware Connection Options

Configuring the Host for Using Remote Console With OpenBoot

Configuring the Host for Using Remote Console With Solaris OS

IPMI Sensor Reference

Sensors on the Sun Blade T6340 Server Module

Indicators on the Sun Blade T6340 Server Module

ALOM CMT Compatibility Shell

Limits to Backward Compatibility

Create an ALOM CMT Compatibility Shell

Switch Between the ALOM CMT Shell and the Host Console

Return to the ILOM From the ILOM CMT Shell

Comparing ILOM and ALOM CMT Commands

ALOM CMT Variables

ALOM CMT Variable Comparison

Event Messages Available Through the ALOM Compatibility Shell

Event Message Overview

Event Severity Levels

Service Processor Usage Event Messages

Environmental Monitoring Event Messages

Host Monitoring Event Messages

SCC Backup and Restore

Information Stored on the SCC

Index

Service Processor Usage Event Messages

The following table displays usage event messages from the service processor (system controller).

System Controller Usage Event Messages
Severity
Message
Description
Critical
Host has been powered off
ALOM compatibility shell sends this message whenever the SC requests a host power off, including when a user types the poweroff command.
Critical
Host has been powered off
ALOM compatibility shell sends this message when the SC requires an immediate host power off, including when a user types the poweroff –f command.
Critical
Host has been powered off
ALOM compatibility shell sends this message when the host power has turned off. It is also normal for this event to be sent when the host has reset itself.
Major
Host has been powered on
ALOM compatibility shell sends this message when the SC requests a host power on, either because of sc_powerstatememory or when a user types the poweron command.
Critical

Critical

Critical

Host has been reset

Host has been powered off

Host has been powered on

ALOM compatibility shell sends one of these messages when the SC requests a host reset, including when a user types the reset command.
Critical
Host System has Reset.
ALOM compatibility shell sends this message when the SC detects that the host has reset. This message is followed immediately by the Host has been powered off event message because reset is implemented as a powercycle on these systems.
Minor
“root : Set : object = /clock/datetime : value = "datetime": success
ALOM compatibility shell sends this message when a user types the setdate command to modify the SC date or time.
Major
Upgrade succeeded
ALOM compatibility shell sends this message after the SC firmware has been reloaded after operation of the flashupdate command.
Minor
“root : Set : object = /HOST/bootmode/state: value = "bootmode-value": success
ALOM compatibility shell sends this message after a user changes the bootmode to normal using the bootmode normal command.
Minor
“root : Set : object = /HOST/bootmode/state: value = "reset_nvram": success
ALOM compatibility shell sends this message after a user changes the boot mode to reset_nvram with the bootmode command.
Minor
"root : Set : object = /HOST/bootmode/script: value = "text": success
ALOM compatibility shell sends this message after a user changes the boot mode boot script. The boot script = "text" is the text of the boot script provided by the user.
Minor
Keyswitch position has been changed to keyswitch_position.
ALOM compatibility shell sends this message after a user changes the keyswitch position with the setkeyswitch command. The keyswitch_position is the new keyswitch position.
Minor
"user" : open session : object = /session/type: value = www/shell: success
ALOM compatibility shell sends this message when users log in. user is the name of the user who just logged in.
Minor
"user" : close session : object = /session/type: value = www/shell: success
ALOM compatibility shell sends this message when users log out. user is the name of the user who just logged out.
Minor
"root : Set: object = /HOST/send_break_action: value = dumpcore : success
ALOM compatibility shell sends this message when an ALOM compatibility shell user sends a request to the host to dump core by typing the break –D command.
Critical
Host Watchdog timeout.
ALOM compatibility shell sends this message when the host watchdog has timed out and the sys_autorestart variable has been set to none. The SC will not perform any corrective measures.
Critical
SP Request to Dump core Host due to Watchdog.
ALOM compatibility shell sends this message when the host watchdog has timed out and the sys_autorestart variable has been set to dumpcore. The SC attempts to perform a core dump of the host to capture error state information. The dump core feature is not supported by all OS versions.
Critical
SP Request to Reset Host due to Watchdog.
ALOM compatibility shell sends this message when the host watchdog has timed out and the sys_autorestart variable has been set to reset. Then the SC attempts to reset the host.