Exit Print View

Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for Sun Blade T6340 Server Modules

Get PDF Book Print View
 

Document Information

Using This Documentation

Related Documentation

Documentation, Support, and Training

Documentation Feedback

Understanding ILOM for the Sun Blade T6340 Server Module

ILOM Overview

Chassis Monitoring Module Features

Updating the System Firmware

Resetting the Password to the Factory Default

Managing the Host

Resetting the Host

Managing Host Boot Mode

Viewing and Configuring Host Control Information

Managing Host Diagnostics and POST

Managing System User Interactions

Managing the Service Processor

Storing Customer Information

Changing Service Processor Settings to Factory Defaults

Display Console History (CLI)

Change Console Escape Characters (CLI)

Changing Configuration Policy Settings

Managing Power Usage and Monitoring Power Consumption

Managing Network Access

Managing SSH Server Settings

Monitoring Active System Faults

Managing Devices

Managing Virtual Keyswitch Settings

Using the Remote Console

Hardware Connection Options

Configuring the Host for Using Remote Console With OpenBoot

Configuring the Host for Using Remote Console With Solaris OS

IPMI Sensor Reference

Sensors on the Sun Blade T6340 Server Module

Indicators on the Sun Blade T6340 Server Module

ALOM CMT Compatibility Shell

Limits to Backward Compatibility

Create an ALOM CMT Compatibility Shell

Switch Between the ALOM CMT Shell and the Host Console

Return to the ILOM From the ILOM CMT Shell

Comparing ILOM and ALOM CMT Commands

ALOM CMT Variables

ALOM CMT Variable Comparison

Event Messages Available Through the ALOM Compatibility Shell

Event Message Overview

Event Severity Levels

Service Processor Usage Event Messages

Environmental Monitoring Event Messages

Host Monitoring Event Messages

SCC Backup and Restore

Information Stored on the SCC

Index

Sensors on the Sun Blade T6340 Server Module

Sensors on the Sun Blade T6340 Server Module
IPMI Name
Full Path
Description
/SYS/SLOTID
/SYS/SLOTID
Identifier of the slot where the blade is installed
/MB/V_+V3_STBY
/SYS/MB/V_+V3_STBY
3.3V standby voltage threshold sensor
/MB/V+1VO
/SYS/MB/V+1VO
MB voltage sensor
/MB/V+1V2
/SYS/MB/V+1V2
MB voltage sensor
/MB/V+1V5IO
/SYS/MB/V+5IO
MB voltage sensor
/MB/V+1V8
/SYS/MB/V+1V8
MB voltage sensor
/MB/V+3V3
/SYS/MB/V+3V3
MB voltage sensor
/MB/V+5V
/SYS/MB/V+5V
MB voltage sensor
/MB/V+12V
/SYS/MB/V+12V
MB voltage sensor
/MB/I+12V
/SYSS/MB/I+12V
MB 12V current sensor, in Amps
/SP/V_BAT
/SYS/SP/V_BAT
Battery voltage threshold sensor
/SYS/VPS
/SYS/VPS
Real-time blade power consumption, in Watts
/MB/V_VDDIO
/SYS/MB/V_DDIO
I/O voltage threshold sensor
/MB/CMPn/V_+1V1
/SYS/MB/CMPn/V_+1V1
CMP (0-1) CPU core voltage sensor
/MB/CMPn/V_+1V5
/SYS/MB/CMPn/V_+1V5
CMP (0-1) CPU core voltage sensor
/MB/CMPn/V_+1V8
/SYS/MB/CMPn/V_+1V8
CMP (0-1) CPU core voltage sensor
/MB/CMPn/I_+1V1
/SYS/MB/CMPn/I_+1V1
CMP (0-1) CPU current draw sensor, in Amps
/MB/CMPn/I_+1V5
/SYS/MB/CMPn/I_+1V5
CMP (0-1) CPU current draw sensor, in Amps
/MB/CMPn/I_+1V8
/SYS/MB/CMPn/I_+1V8
CMP (0-1) CPU current draw sensor, in Amps
/MB/CMPn/T_+1V1
/SYS/MB/CMPn/T_+1V1
CMP (0-1) temperature sensor for voltage regulators, in degrees Celsius.
/MB/CMPn/T_+1V5
/SYS/MB/CMPn/T_+1V8
CMP (0-1) temperature sensor for voltage regulators, in degrees Celsius.
/MB/CMPn/T_+1V8
/SYS/MB/CMPn/T_+1V8
CMP (0-1) temperature sensor for voltage regulators, in degrees Celsius.
/Pn/BRn/CHn/Dn/P
/SYS/MB/Pn/BRn/CHn/Dn/P
CMP (0-1) DIMM presence sensors defined by branch BRn (where n= 0 or 1), channel CHn (where n= 0 or 1), and DIMM Dn (where n is an integer 0-3).
/MB/Pn/CBUS_BTn
/SYS/MB/Pn/CBUS_BTn
CMP (0-1) CPU corner bus test point, for point CBUS_BTn, where n is an integer 0-11.
/MB/CMPn/T_IN
/SYS/MB/CMPn/T_IN
CMP (0-1) temperature leading into the CPU, in degrees Celsius.
/MB/CMPn/T_TCORE
/SYS/MB/CMPn/T_TCORE
CMP (0-1) CPU temperature sensor at the top of the chip, in degrees Celsius.
/MB/CMPn/T_BCORE
/SYS/MB/CMPn/T_BCORE
CMP (0-1) CPU temperature sensor at the bottom of the chip, in degrees Celsius.
/Pn/BRn/CHn/Dn/T_AMB
/SYS/MB/Pn/BRn/CHn/Dn/T_AMB
CMP (0-1) temperature sensor (in degrees Celsius) defined by branch BRn (where n= 0 or 1), channel CHn (where n= 0 or 1), and DIMM Dn (where n is an integer 0-3).
/HDDn/PRSNT
/SYS/HDDn/PRSNT
Hard disk drive (0-1) presence sensors
/NEMn/PRSNT
/SYS/NEMn/PRSNT
Network Express Module (NEM) disk (0-1) presence sensors.
/PSn/PRSNT
/SYS/PSn/PRSNT
PS (0-1) chassis component sensors.
/FMn/PRSNT
/SYS/FMn/PRSNT
FM (0-5) chassis component sensors.
/FMn/Fn/TACH
/SYS/FMn/Fn/TACH
FM (0-5) tachometer (in RPM) for Fn, where n = 0 or 1.
/FMn/SERVICE
/SYS/FMn/SERVICE
FM (0-5) service sensor.
/PSn/VINOKn
/SYS/PSn/VINOKn
PS (0-1) sensor for VINOKn, where n = 0 or 1.
/PSn/PWROKn
/SYS//PSn/PWROKn
PS (0-1) sensor for PWROKn, where n = 0 or 1.
/PSn/FANOK
/SYS/PSn/FANOK
PS (0-1) fan OK sensor
/PSn/TEMPOK
/SYS/PSn/TEMPOK
PS (0-1) temperature OK sensor
/PSn/V12VOKn
/SYS/PSn/V12VOKn
PS (0-1) OK sensor for IV12VOKn, where n = 0 or 1.
/PSn/I12VOKn
/PSn/I12VOKn
PS (0-1) OK sensor for V12VOKn, where n = 0 or 1.
/MB/FEM/PRSNT
/SYS/MB/FEM/PRSNT
FEM presence sensor.
/MB/FEM/PRSNT
/SYS/MB/FEM/PRSNT
REM presence sensor