/SYS/SLOTID |
/SYS/SLOTID |
Identifier of the slot where the blade is installed |
/MB/V_+V3_STBY |
/SYS/MB/V_+V3_STBY |
3.3V standby voltage threshold sensor |
/MB/V+1VO |
/SYS/MB/V+1VO |
MB voltage sensor |
/MB/V+1V2 |
/SYS/MB/V+1V2 |
MB voltage sensor |
/MB/V+1V5IO |
/SYS/MB/V+5IO |
MB voltage sensor |
/MB/V+1V8 |
/SYS/MB/V+1V8 |
MB voltage sensor |
/MB/V+3V3 |
/SYS/MB/V+3V3 |
MB voltage sensor |
/MB/V+5V |
/SYS/MB/V+5V |
MB voltage sensor |
/MB/V+12V |
/SYS/MB/V+12V |
MB voltage sensor |
/MB/I+12V |
/SYSS/MB/I+12V |
MB 12V current sensor, in Amps |
/SP/V_BAT |
/SYS/SP/V_BAT |
Battery voltage threshold sensor |
/SYS/VPS |
/SYS/VPS |
Real-time blade power consumption, in Watts |
/MB/V_VDDIO |
/SYS/MB/V_DDIO |
I/O voltage threshold sensor |
/MB/CMPn/V_+1V1 |
/SYS/MB/CMPn/V_+1V1 |
CMP (0-1) CPU core voltage sensor |
/MB/CMPn/V_+1V5 |
/SYS/MB/CMPn/V_+1V5 |
CMP
(0-1) CPU core voltage sensor |
/MB/CMPn/V_+1V8 |
/SYS/MB/CMPn/V_+1V8 |
CMP (0-1) CPU core voltage sensor |
/MB/CMPn/I_+1V1 |
/SYS/MB/CMPn/I_+1V1 |
CMP (0-1) CPU current draw sensor, in Amps |
/MB/CMPn/I_+1V5 |
/SYS/MB/CMPn/I_+1V5 |
CMP (0-1) CPU current draw sensor, in Amps |
/MB/CMPn/I_+1V8 |
/SYS/MB/CMPn/I_+1V8 |
CMP (0-1) CPU current draw sensor, in Amps |
/MB/CMPn/T_+1V1 |
/SYS/MB/CMPn/T_+1V1 |
CMP (0-1) temperature sensor for voltage regulators, in degrees Celsius. |
/MB/CMPn/T_+1V5 |
/SYS/MB/CMPn/T_+1V8 |
CMP (0-1) temperature sensor for voltage regulators, in degrees Celsius. |
/MB/CMPn/T_+1V8 |
/SYS/MB/CMPn/T_+1V8 |
CMP (0-1) temperature sensor for voltage regulators, in degrees Celsius. |
/Pn/BRn/CHn/Dn/P |
/SYS/MB/Pn/BRn/CHn/Dn/P |
CMP (0-1) DIMM presence sensors defined by branch BRn
(where n= 0 or 1), channel CHn (where n= 0 or 1), and DIMM Dn (where n is an integer 0-3). |
/MB/Pn/CBUS_BTn |
/SYS/MB/Pn/CBUS_BTn |
CMP (0-1) CPU corner bus test point, for point CBUS_BTn, where n is an integer 0-11. |
/MB/CMPn/T_IN |
/SYS/MB/CMPn/T_IN |
CMP (0-1) temperature leading into the CPU, in degrees Celsius. |
/MB/CMPn/T_TCORE |
/SYS/MB/CMPn/T_TCORE |
CMP (0-1) CPU temperature sensor at the top of the chip, in degrees Celsius. |
/MB/CMPn/T_BCORE |
/SYS/MB/CMPn/T_BCORE |
CMP (0-1) CPU temperature sensor at the bottom of the chip, in degrees Celsius. |
/Pn/BRn/CHn/Dn/T_AMB |
/SYS/MB/Pn/BRn/CHn/Dn/T_AMB |
CMP (0-1) temperature sensor (in degrees Celsius) defined by branch BRn
(where n= 0 or 1), channel CHn (where n= 0 or 1), and DIMM Dn (where n is an integer 0-3). |
/HDDn/PRSNT |
/SYS/HDDn/PRSNT |
Hard disk drive (0-1) presence sensors |
/NEMn/PRSNT |
/SYS/NEMn/PRSNT |
Network Express Module (NEM) disk (0-1) presence sensors. |
/PSn/PRSNT |
/SYS/PSn/PRSNT |
PS (0-1) chassis component sensors. |
/FMn/PRSNT |
/SYS/FMn/PRSNT |
FM (0-5) chassis component sensors. |
/FMn/Fn/TACH |
/SYS/FMn/Fn/TACH |
FM (0-5) tachometer (in RPM) for Fn, where n = 0 or 1. |
/FMn/SERVICE |
/SYS/FMn/SERVICE |
FM
(0-5) service sensor. |
/PSn/VINOKn |
/SYS/PSn/VINOKn |
PS (0-1) sensor for VINOKn, where n = 0 or 1. |
/PSn/PWROKn |
/SYS//PSn/PWROKn |
PS
(0-1) sensor for PWROKn, where n = 0 or 1. |
/PSn/FANOK |
/SYS/PSn/FANOK |
PS (0-1) fan OK sensor |
/PSn/TEMPOK |
/SYS/PSn/TEMPOK |
PS (0-1) temperature OK sensor |
/PSn/V12VOKn |
/SYS/PSn/V12VOKn |
PS (0-1) OK sensor for IV12VOKn, where n =
0 or 1. |
/PSn/I12VOKn |
/PSn/I12VOKn |
PS (0-1) OK sensor for V12VOKn, where n = 0 or 1. |
/MB/FEM/PRSNT |
/SYS/MB/FEM/PRSNT |
FEM presence sensor. |
/MB/FEM/PRSNT |
/SYS/MB/FEM/PRSNT |
REM presence sensor |