JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Oracle Integrated Lights Out Manager (ILOM) 3.0 HTML Documentation Collection
search filter icon
search icon

Document Information

Using This Documentation

Related Documentation

Documentation Feedback

Product Downloads

Download Product Software and Firmware

Oracle ILOM 3.0 Firmware Version Numbering Scheme

Support and Accessibility

Feature Updates and Release Notes

Oracle ILOM 3.0 Feature Set

Oracle ILOM 3.0 Feature Set Overview

Updates to Oracle ILOM 3.0.3 Firmware

New Features for Oracle ILOM 3.0.3

Resolved Issues as of Oracle ILOM 3.0.3

Known Issues as of Oracle ILOM 3.0.3

Updates to Oracle ILOM 3.0.4 Firmware

New Features for Oracle ILOM 3.0.4

Resolved Issues as of Oracle ILOM 3.0.4

Known Issues as of Oracle ILOM 3.0.4

Updates to Oracle ILOM 3.0.6 Firmware

New Features for Oracle ILOM 3.0.6

Resolved Issues as of Oracle ILOM 3.0.6

Known Issues as of Oracle ILOM 3.0.6

Updates to Oracle ILOM 3.0.8 Firmware

New Features for Oracle ILOM 3.0.8

Resolved Issues as of Oracle ILOM 3.0.8

Known Issues as of Oracle ILOM 3.0.8

Updates to Oracle ILOM 3.0.9 Firmware

New Features for Oracle ILOM 3.0.9

Resolved Issue as of Oracle ILOM 3.0.9

Known Issues as of Oracle ILOM 3.0.9

Updates to Oracle ILOM 3.0.10 Firmware

New Features for Oracle ILOM 3.0.10

Resolved Issues as of Oracle ILOM 3.0.10

Known Issues as of Oracle ILOM 3.0.10

Updates to Oracle ILOM 3.0.12 and Oracle ILOM 3.0.14 Firmware

New Features for Oracle ILOM 3.0.12 and Oracle ILOM 3.0.14

Resolved Issues as of Oracle ILOM 3.0.14

Known Issue as of Oracle ILOM 3.0.12

Updates to Oracle ILOM 3.0.16 Firmware

Resolved Issues as of ILOM 3.0.16

Documentation Known Issue

Known Issues as of Oracle ILOM 3.0.16

Enhancements to Oracle ILOM Documentation Library

Quick Start

Oracle ILOM 3.0 – Quick Start

Factory Default Settings

Mandatory Setup Tasks

Optional Setup Tasks

Daily Management Tasks

Routine Maintenance Tasks

Initial Setup FAQs

Remote Redirection Consoles

Oracle ILOM Web and CLI Remote Redirection Options

Oracle ILOM Remote Console

Oracle ILOM Storage Redirection CLI

Starting and Stopping a Host Console

Understanding Oracle ILOM Remote Console Features

International Keyboard Support

Single or Multiple Management Views

Network Communication Ports and Protocols

Sign-In Authentication

Secure Remote Console

Setting Up the Oracle ILOM Remote Console for First-Time Use

Initial Setup Requirements (Oracle ILOM Remote Console)

Configure KVMS Redirection Settings

Registering 32-bit JDK

Securing the Oracle ILOM Remote Console

Launching and Redirecting KVMS Devices Using the Oracle ILOM Remote Console

Usage Requirements (Oracle ILOM Remote Console)

International Keyboard Support

Launch the Oracle ILOM Remote Console

Start, Stop, or Restart Device Redirection

Toggle Keyboard and Mouse Control

Control Keyboard Modes and Key Send Options

Redirect Keyboard Input (Serial Redirection Only)

Redirect Mouse Input (Video Redirection Only)

Redirect Storage Media

Add New Server Redirection Session

Exit the Oracle ILOM Remote Console

Understanding Oracle ILOM Storage Redirection CLI Features

First-Time Use (Oracle ILOM Storage Redirection CLI)

Storage Redirection CLI Architecture

Default Network Communication Port

Setting Up Oracle ILOM Storage Redirection CLI for First Time Use

Initial Setup Requirements (Oracle ILOM Storage Redirection CLI)

Change the Default Storage Redirection Network Port: 2121

Starting the Storage Redirection Service

Download and Install the Storage Redirection Client

Redirecting a Storage Device Using the Oracle ILOM Storage Redirection CLI

Usage Requirements (Storage Redirection CLI)

Launch the Storage Redirection CLI Using a Command Window or Terminal

Verify That the Storage Redirection Service Is Running

Display Storage Redirection CLI Help Information

Start Redirection of Storage Device

View Active Storage Redirections

Stop Redirection of Storage Device

Supported Storage Redirection Commands and Options

Daily Management Concepts

Oracle ILOM Overview

What Is Oracle ILOM?

What Does Oracle ILOM Do?

Oracle ILOM Features and Functionality

New Features in Oracle ILOM 3.0

User Accounts – Backward Compatibly

Preconfigured User Accounts

Oracle ILOM Supported Interfaces

Oracle ILOM on the Server SP and CMM

System Banner Messages

Network Configurations

Oracle ILOM Network Management

Switch Serial Port Console Output (Serial Port Owner)

Oracle ILOM Communication Settings

SP Management Port – Recommended Practice for Spanning Tree Parameters

Network Configurations for IPv4

Dual-Stack Network Configurations for IPv4 and IPv6 (ILOM 3.0.12)

Local Interconnect Interface: Local Connection to ILOM From Host OS

User Account Management

Guidelines for Managing User Accounts

User Account Roles and Privileges

Single Sign On

SSH User Key-Based Authentication

Active Directory

Lightweight Directory Access Protocol

LDAP/SSL

RADIUS

System Monitoring and Alert Management

System Monitoring

Alert Management

Storage Monitoring and Zone Management

Storage Monitoring for HDDs and RAID Controllers

CMM Zone Management Feature

Power Monitoring and Management of Hardware Interfaces

Summary of Power Management Feature Updates

Power Monitoring Terminology

Real-Time Power Monitoring and Management Features

Remote Host Management Operations

Remote Power Control

Host Control - Boot Device on x86 Systems

Oracle ILOM Operations for LDom Configurations on SPARC Servers

Remote Redirection Console Options

Oracle ILOM Host Maintenance and Diagnostics Options

Host Maintenance Operations

Host Diagnostic Options

Example Setup of Dynamic DNS

Dynamic DNS Overview

Example Dynamic DNS Configuration

Daily Management CLI Procedures

CLI Overview

Oracle ILOM CLI — DMTF Server Management Command-Line Protocol User-Interface

Oracle ILOM CLI Connection

Oracle ILOM CLI Management Namespace

Entering CLI Command Syntax and Executing Commands

Common CLI Commands

Oracle ILOM 3.0 Properties Versus Oracle ILOM 2.x Properties

Logging In to ILOM, Displaying Banner Messages, and Setting the CLI Session Time-out

Logging In and Out of ILOM and Recovering a Password

Setting Up Banner Messages and CLI Session Time-Out

Configuring Network, Secure Shell, and Local Interconnect Settings

Configuring Network Settings (CLI)

Configuring Secure Shell Settings (CLI)

Configuring the Local Interconnect Interface (CLI)

Managing User Accounts (CLI)

Configuring User Accounts (CLI)

Configuring SSH User Keys (CLI)

Configuring Active Directory (CLI)

Configuring Lightweight Directory Access Protocol (LDAP) (CLI)

Configuring LDAP/SSL (CLI)

Configuring RADIUS (CLI)

Managing Component Status and Service Actions (CLI)

View Component Information (CLI)

Prepare to Remove a Component (CLI)

Return a Component to Service (CLI)

Enable and Disable Component State (CLI)

View and Clear Faults (CLI)

Monitoring System Sensors and Managing Event Log Entries and Clock Settings (CLI)

Monitoring System Sensors, Indicators, Event Logs (CLI)

View and Manage SP Console Log Output (CLI)

Monitoring Storage Components and Zone Manager

Monitor Storage Component Details on x86 Servers (CLI)

Accessing Sun Blade Zone Manager Functions

Managing System Alerts (CLI)

Managing Alert Rule Configurations (CLI)

CLI Commands: Alert Rules

Configure the SMTP Client (CLI)

Redirecting Storage Media and Locking the Oracle ILOM Remote Console Display

Redirect Storage Media (CLI)

Manage Oracle ILOM Remote Console Lock Options (CLI)

Power Monitoring and Managing of Hardware Interfaces

Summary of Power Management Feature Updates (CLI)

Monitoring System Power Consumption (CLI)

Configuring the Power Policy and Notification Threshold Values (CLI)

Monitoring Component Power Allocation Distributions (CLI)

Configuring Power Limit Properties (CLI)

Manage CMM Power Supply Redundancy Properties (CLI)

Managing Remote Host Power States, BIOS Boot Device, and Host Server Console

Issuing Remote Power State Commands From Server SP CLI or CMM CLI

Configure BIOS Host Boot Device Override (CLI)

Managing the SP Host Console

bootManaging TPM and LDom States on SPARC Servers (CLI)

Control TPM State on a SPARC Server (CLI)

Managing LDom Configurations on SPARC Servers (CLI)

CLI Command Reference

cd Command

create Command

delete Command

dump Command

exit Command

help Command

load Command

reset Command

set Command

show Command

start Command

stop Command

version Command

Diagnosing IPv4 or IPv6 Oracle ILOM Connection Issues

Diagnosing Oracle ILOM Connection Issues

Manual Host OS Configuration Guidelines for Local Interconnect Interface

Configuring Internal USB Ethernet Device on Host OS

Daily Management Web Procedures

Web Interface Overview

About the Web Interface

Browser and Software Requirements

CMM and Server SP Web Interface Connection

Web Interface Navigation Tabs

Logging In to and Out of Oracle ILOM and Displaying Banner Messages (Web)

Before Your Initial Login

Log In Using the Root User Account (Web)

Log In to Oracle ILOM With User Account (Web)

Log Out of Oracle ILOM (Web)

Display Banner Messages on Login Page (Web)

Configuring Network, Secure Shell, and Local Interconnect Settings (Web)

Configuring Network Settings (Web)

Configuring Secure Shell Settings

Configuring the Local Interconnect Interface (Web)

Managing User Accounts (Web)

Configuring User Accounts (Web)

Configuring SSH Keys (Web)

Configuring Active Directory (Web)

Configuring Lightweight Directory Access Protocol (LDAP)

Configuring LDAP/SSL Settings (Web)

Configuring RADIUS (Web)

Managing Component Status and Service Actions (Web)

View Component Status Information (Web)

Prepare to Remove a Component (Web)

Return a Component to Service (Web)

Enable or Disable Components (Web)

Clear Faults Detected by Oracle ILOM (Web)

Monitoring System Sensors and Managing the Event Log (Web)

View Sensor Readings (Web)

Configure System Indicators (Web)

Configure Clock Settings (Web)

Configure Time Zone Settings (Web)

Filter Event Log Output (Web)

View and Clear Oracle ILOM Event Log (Web)

Configure Remote Syslog Receiver IP Addresses (Web)

Monitoring Storage Components and Zone Manager (Web)

Requirements for Monitoring Storage Components

View and Monitor RAID Controller Details (Web)

View and Monitor Details for Disks That Are Attached to RAID Controllers (Web)

View and Monitor RAID Controller Volume Details (Web)

Enabling or Disabling Zone Manager for SAS-2 Storage Devices

Managing System Alerts and Email Notifications (Web)

Managing Alert Rule Configurations (Web)

Configuring SMTP Client for Email Notification Alerts (Web)

Power Monitoring and Management of Hardware Interfaces (Web)

Summary of Power Management Feature Updates (Web)

Monitoring System Power Consumption (Web)

Configuring Power Policy Settings to Manage Server Power Usage (Web)

Configuring Power Consumption Threshold Notifications (Web)

Monitoring and Configuring Component Power Allocation Distributions (Web)

Configuring Server Power Limit Properties (Web)

Monitoring or Configuring CMM Power Supply Redundancy (Web)

Managing Remote Hosts Redirection and Securing the Oracle ILOM Remote Console (Web)

Web Procedures for Redirecting Remote Host KVMS

Managing Remote Hosts Power States (Web)

Controlling Power States From Remote Server SP or CMM (Web)

Managing Host Control of Boot Device on x86 Systems (Web)

Managing TPM and LDom States on SPARC Servers (Web)

Controlling the TPM State on SPARC Servers (Web)

Managing LDom Configurations on SPARC Servers (Web)

Diagnosing IPv4 or IPv6 Oracle ILOM Connection Issues

Diagnosing Oracle ILOM Connection Issues

Manual Host OS Configuration Guidelines for Local Interconnect Interface

Configuring Internal USB Ethernet Device on Host OS

Maintenance and Diagnostics CLI and Web Procedures

Maintenance Operations Overview

Firmware Updates Using Oracle ILOM

Service Processor (SP) Reset

Back Up, Restore, and Reset Oracle ILOM Configurations

Updating Firmware

Updating Firmware Using Oracle ILOM (Web)

Updating Firmware Using Oracle ILOM (CLI)

Resetting the Service Processor Using Oracle ILOM

Reset the SP Using the Oracle ILOM Web Interface

Reset the SP Using the Oracle ILOM CLI

Backing Up, Restoring, or Resetting Oracle ILOM Configurations

Backing Up Configurations

Optionally Edit the Backup XML File

Restoring Configurations

Resetting Oracle ILOM Configuration Settings to the Defaults

Diagnostic Tools Overview

Server SP Diagnostic Tools

Oracle Service-Designated Diagnostic Tools

x86 Server SP Diagnostic Tools

Diagnosing x86 Systems Hardware Issues (Web)

Diagnosing x86 Systems Hardware Issues (CLI)

SPARC Server SP Diagnostic Tools

Diagnosing SPARC Systems Hardware Issues (Web)

Diagnosing SPARC Systems Hardware Issues (CLI)

Oracle Services-Designated Diagnosic Tools

Collecting SP Data to Diagnose System Problems

Using the Oracle ILOM Fault Management Shell

Protocol Management CLI and Web Procedures

SNMP Overview

About Simple Network Management Protocol

SNMP Components

Oracle ILOM SNMP MIBs

Configuring SNMP Settings in Oracle ILOM

Managing SNMP Read and Write Access, User Accounts, and SNMP Trap Alerts (CLI)

Managing SNMP Read and Write Access, User Accounts, and SNMP Trap Alerts (Web)

Downloading SNMP MIBs Using Oracle ILOM

Manage User Accounts Using SNMP

Before You Begin - User Accounts (SNMP)

Configuring User Accounts (SNMP)

Configuring Active Directory Settings

Manage DNS Name Server Settings (SNMP)

Configuring ILOM for LDAP (SNMP)

Configuring ILOM for LDAP/SSL

Configuring RADIUS Settings (SNMP)

Manage Component Information and Email Alerts (SNMP)

Before You Begin - Component Information (SNMP)

Viewing Component Information

Managing Clock Settings, Event Log, Syslog Receiver, and Alert Rules

Configuring SMTP Client for Email Alert Notifications

Configuring Email Alert Settings (SNMP)

Configuring Telemetry Harness Daemon (SNMP)

Monitor and Manage System Power (SNMP)

Before You Begin - Power Management (SNMP)

Monitoring the Power Consumption Interfaces (SNMP)

Maintaining System Power Policy (SNMP)

Managing System Power Properties (SNMP)

Manage Oracle ILOM Firmware Updates (SNMP)

Update Oracle ILOM Firmware (SNMP)

Manage ILOM Backup and Restore Configurations (SNMP)

View and Configure Backup and Restore Properties (SNMP)

Manage SPARC Diagnostics, POST, and Boot Mode Operations (SNMP)

Before You Begin - Manage SPARC Hosts (SNMP)

Managing SPARC Diagnostic, POST, and Boot Mode Properties (SNMP)

Server Managment Using IPMI

Intelligent Platform Management Interface (IPMI)

Configuring the IPMI State

Using IPMItool to Run ILOM CLI Commands

Performing System Management Tasks (IPMItool)

IPMItool Utility and Command Summary

Server Management Using WS-Management and CIM

WS-Management and CIM Overview

Configuring Support for WS-Management in ILOM

Supported DMTF SMASH Profiles, CIM Classes and CIM Indications

Oracle's Sun-Supported CIM Classes

Document Conventions For Oracle's Sun-Supported CIM Classes

Oracle_AssociatedIndicatorLED

Oracle_AssociatedSensor

Oracle_Chassis

Oracle_ComputerSystem

Oracle_ComputerSystemPackage

Oracle_Container

Oracle_ElementCapabilities

Oracle_ElementConformsToProfile

Oracle_EnabledLogicalElementCapabilities

Oracle_HWCompErrorOkIndication

Oracle_IndicatorLED

Oracle_InstCreation

Oracle_InstDeletion

Oracle_LogEntry

Oracle_LogManagesRecord

Oracle_Memory

Oracle_NumericSensor

Oracle_PhysicalAssetCapabilities

Oracle_PhysicalComponent

Oracle_PhysicalElementCapabilities

Oracle_PhysicalMemory

Oracle_PhysicalPackage

Oracle_Processor

Oracle_ProcessorChip

Oracle_Realizes

Oracle_RegisteredProfile

Oracle_RecordLog

Oracle_ReferencedProfile

Oracle_Sensor

Oracle_SpSystemComponent

Oracle_SystemDevice

Oracle_ThresholdIndication

Oracle_UseOfLog

SNMP Command Examples

snmpget Command

snmpwalk Command

snmpbulkwalk Command

snmptable Command

snmpset Command

snmptrapd Command

CMM Administration CLI and Web Procedures

Oracle ILOM CMM Overview

About the Modular System Chassis

Oracle ILOM CMM Function Overview

Oracle ILOM Versions

Oracle ILOM CMM Documentation

About This Document

Oracle ILOM CMM Initial Setup

Connecting to the Oracle ILOM CMM

Log In to the Oracle ILOM CMM Using a Network Connection

Activating CMM Ethernet Ports

Changing the Blade SP CLI Prompt

Firmware Update Procedures

Updating the Oracle ILOM CMM Firmware

Updating the NEM Firmware

Updating Chassis Component Firmware Using the CMM

Resetting the Oracle ILOM CMM

CMM Power Management

Light Load Efficiency Mode (LLEM)

Force Power Supply Fan Speed

Disabling the Power Management Policy

Oracle ILOM 3.0 for Specific Sun Blade 6048 Cases

SAS Zoning Chassis Blade Storage Resources

Zone Management for Chassis-Level SAS-2 Capable Resources

Manageable SAS-2 Zoning-Capable Devices

Sun Blade Zone Manager Properties

Important SAS Zoning Allocations Considerations

Enabling Zoning and Creating SAS-2 Zoning Assignments

Managing Existing SAS-2 Storage Resource Allocations

Resetting Sun Blade Zone Manager Allocations to Factory Defaults

Resetting the Zoning Password to Factory Default for Third-Party In-Band Management

Glossary

Index

Oracle_Chassis

Description:
The Oracle_Chassis class represents the physical elements that enclose other elements.
Inheritance:
CIM_Chassis
Properties:
For a description of the supported properties for the Oracle_Chassis class, see the following table.

Note - For more details about Oracle's Sun-supported properties (described in the following table), see the DMTF CIM schema, version 2.18.1, at:


http://www.dmtf.org/standards/cim/cim_schema_v2181

Profile:
Physical Asset

Table 78 Properties for Oracle_Chassis  

Property
Data Type
Description
ILOM Value
CreationClassName

string
The CreationClassName property is a mandatory key property

CreationClassName indicates the name of the class or the subclass used in the creation of an instance. When used with the other key properties of this class, this property allows all instances of this class and its subclasses to be uniquely identified.

Set to Oracle_Chassis
Tag

string
The Tag property is a mandatory key property.

The Tag property is an arbitrary string that uniquely identifies the physical element and serves as the key of the element.

The Tag property can contain information such as asset tag or serial number data.

The key for PhysicalElement is placed very high in the object hierarchy in order to independently identify the hardware or entity, regardless of physical placement in or on cabinets, adapters, and so on.

For example, a hot-swappable or removable component can be taken from its containing (scoping) Package and be temporarily unused. The object still continues to exist and can be inserted into a different scoping container. Therefore, the key for PhysicalElement is an arbitrary string and is defined independently of any placement or location-oriented hierarchy.

Set to component NAC name
CanBeFRUed
boolean
The CanBeFRUed property is a boolean that indicates whether this PhysicalElement can be FRUed (TRUE) or not (FALSE).
Will be set to TRUE or FALSE depending on whether the component is considered to be a FRU by the platform.
ChassisPackageType
uint16[]
The ChassisPackageType property indicates the physical form factor for the type of chassis.

This property may have a value when the PackageType property contains the value 3 Chassis Frame. A value of 28 Blade Enclosure indicates the Chassis is designed to contain one or more PhysicalPackage(s) of PackageType 16 "Blade" or PackageType 17 "Blade Expansion".

Definition type values include any of the following:

{Unknown, Other, SMBIOS Reserved, Desktop, Low Profile Desktop, Pizza Box, Mini Tower, Tower, Portable, LapTop, Notebook, Hand Held, Docking Station, All in One, Sub Notebook, Space-Saving, Lunch Box, Main System Chassis, Expansion Chassis, SubChassis, Bus Expansion Chassis, Peripheral Chassis, Storage Chassis, SMBIOS Reseved, Sealed-Case PC, SMBIOS Reserved, CompactPCI, AdvancedTCA, Blade Enclosure, DMTF Reserved, Vendor Reserved}

Values for the definition types are:

{0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, .., 0x8000..0xFFFF}

Will be set to 17 (Main System Chassis)
ChassisTypeDescription
string
The ChassisTypeDescription is a string providing more information about the ChassisPackageType.
Will have appropriate description.
Description
string
Textual description of the object.
Will have appropriate description.
ElementName
string
The ElementName property is a user-friendly name.

This property allows each instance to define a user-friendly name in addition to its key properties, identity data, and description information.


Note - The Name property of ManagedSystemElement is also defined as a user-friendly name. But, it is often subclassed to be a key. It is not reasonable that the same property can convey both identity and a user-friendly name, without inconsistencies. Where Name exists and is not a key (such as for instances of LogicalDevice), the same information can be present in both the Name and ElementName properties.


Set to component NAC name.
HealthState
uint16[]
Indicates the current health of the element. This attribute expresses the health of this element but not necessarily that of its subcomponents. The following values apply:
  • 0 (Unknown) - The implementation cannot report on HealthState at this time.

  • 5 (OK) - The element is fully functional and is operating within normal operational parameters and without error.

  • 10 (Degraded/Warning) - The element is in working order and all functionality is provided. However, the element is not working to the best of its abilities. For example, the element might not be operating at optimal performance or it might be reporting recoverable errors.

  • 15 (Minor Failure) - All functionality is available but some might be degraded.

  • 20 (Major Failure) - The element is failing. It is possible that some or all of the functionality of this component is degraded or not working.

  • 25 (Critical Failure) - The element is non-functional and recovery might not be possible.

  • 30 (Non-Recoverable Error) - The element has completely failed, and recovery is not possible. All functionality provided by this element has been lost.

DMTF has reserved the unused portion of the continuum for additional health states in the future.

Will have appropriate value depending on whether the component is in error state or not.
Manufacturer
string
The Manufacturer property is the name of the organization responsible for producing the PhysicalElement.

This organization might be the entity from whom the element is purchased, but this is not necessarily true. The latter information is contained in the vendor property of CIM_Product.

Will have appropriate value if the chassis is considered a FRU by the platform.
Model
string
The Model property is the name by which the PhysicalElement is generally known.
Will have appropriate value if the chassis is considered a FRU by the platform.
OperationalStatus
uint16[]
The OperationalStatus property indicates the current statuses of the element.

Various operational statuses are defined. Many of the enumeration's values are self-explanatory.

Enumeration definitions can include any of the following:

{Unknown, Other, OK, Degraded, Stressed, Predictive Failure, Error, Non-Recoverable Error, Starting, Stopping, Stopped, In Service, No Contact, Lost Communication, Aborted, Dormant, Supporting Entity in Error, Completed, Power Mode, DMTF Reserved, Vendor Reserved}

Values for these definitions are as follows:

{0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, .., 0x8000..}

OperationalStatus[0] will have appropriate value depending on whether the component is in error state or not.
PartNumber
string
Part number assigned by the organization that is responsible for producing or manufacturing the PhysicalElement
Will have appropriate value if the chassis is considered a FRU by the platform.
SKU
string
The SKU property is the stock-keeping unit number for this PhysicalElement.
Will have appropriate value if the chassis is considered a FRU by the platform.
SerialNumber
string
The SerialNumber property is a manufacturer-allocated number used to identify the physical element.
Will have appropriate value if the chassis is considered a FRU by the platform.
StatusDescriptions
string
That StatusDescriptions property describes the various OperationalStatus array values.

For example, if -Stopping is the value assigned to OperationalStatus, then this property may contain an explanation as to why an object is being stopped.

Note that entries in this array are correlated with those at the same array index in OperationalStatus.

StatusDescriptions[0] will have appropriate description on the reason for the value of OperationalStatus[0]