Oracle Server CLI Tools Overview
CLI Tools Command Syntax and Conventions
How to List Subsystem Information
The open_problems subsystem is available for Oracle Hardware Management 2.2.4 and later.
hwmgmtcli list open_problems
The following display shows sample output from this command for Oracle HMP 2.2.4 and 2.2.5:
Date/Time Subsystems Component ------------------------ ------------------ ------------ Fri Apr 27 13:14:46 2012 Cooling FM3 (Fan Module 3) Fan tachometer speed is below its normal operating range. (Probability: 100, UUID: 6f6ef474-5059-c11e-98db-b52f6ffbffa6, Part Number: N/A, Seria l Number: N/A, Reference Document: http://www.sun.com/msg/SPX86-8000-33) Fri Apr 27 14:03:56 2012 Processors P1 (CPU 1) An integrated I/O (IIO) hot-plug I/O extender port error has occurred. ( Probability: 100, UUID: e2dadf98-24e0-6058-ce74-b87844c4b894, Part Numbe r: 060D, Serial Number: N/A, Reference Document: http://www.sun.com/msg/ SPX86-8003-PD) Mon May 28 07:08:48 2012 System MB (Motherboard) Power to server is not available due to a malfunctioning component detec ted by CPLD. (Probability: 100, UUID: ee437083-990b-eb6c-8665-8d952319ab 1d, Part Number: 7024015-01, Serial Number: 489089M+1135PR00CX, Referenc e Document: http://www.sun.com/msg/SPX86-8002-2J) Fri Jun 8 05:27:42 2012 Processors P0 (CPU 0) An integrated I/O (IIO) hot-plug I/O extender port error has occurred. ( Probability: 100, UUID: ae3b229a-57f6-67f3-8d3f-fcb7f350fa0d, Part Numbe r: 060D, Serial Number: N/A, Reference Document: http://www.sun.com/msg/ SPX86-8003-PD)
The following display shows sample output from this command for Oracle HMP 2.2.6 and later:
=== open_problems report === Open Problem 1 Problem time : Thu Feb 14 22:38:19 2013 Problem subsystem : System Problem location : /SYS (Host System) Problem description : The top cover of server was opened while AC input was still applied to the power supplies. (Probability: 100, UUID: 8bb87e70-d210-632b-d553-fc1450105bc4, Part Number: 31112054+1+1, Serial Number: 1242FML0UV, Reference Document: http://www.sun.com/msg/SPX86-8003-8C). Open Problem 2 Problem time : Fri Feb 15 10:37:48 2013 Problem subsystem : Storage Problem location : /SYS/DBP0/HDD2 Problem description : The disk temperature has exceeded the critical limit. (Probability: 100, UUID: N/A, Part Number: H106030SDSUN300G, Serial Number: 001234NTR1KD PWGTR1KD, Reference Document: N/A)