Oracle® VM Server for SPARC 3.3 Administration Guide

Exit Print View

Updated: October 2015
 
 

How to Verify the ILOM Interconnect Configuration

  1. Verify that the ilomconfig-interconnect service is enabled.
    primary# svcs ilomconfig-interconnect
    STATE          STIME    FMRI
    online          9:53:28 svc:/network/ilomconfig-interconnect:default
  2. Verify that the ILOM interconnect is configured properly.

    A proper configuration shows the State value as enabled and the Host Interconnect IP Address value as an IP address and not none.

    primary# ilomconfig list interconnect
    Interconnect
    ============
    State: enabled
    Type: USB Ethernet
    SP Interconnect IP Address: 169.254.182.76
    Host Interconnect IP Address: 169.254.182.77
    Interconnect Netmask: 255.255.255.0
    SP Interconnect MAC Address: 02:21:28:57:47:16
    Host Interconnect MAC Address: 02:21:28:57:47:17
  3. Verify that the ldmd daemon can communicate with the SP.
    primary# ldm list-spconfig