Controller Cabling

External cabling for the Controllers provides the interface to the customer data network. Internal cabling supports the private management interface (PMI) and the Backend SAS Interconnect.

Controller Ports for External Cabling

The following figure shows the SAN HBA ports.

Figure 1: Controller ports for external cabling

 Controller ports for external cabling 
Legend
1 SAN HBA ports connect the system to the customer data network (FC or iSCSI)

Controller Ports for Internal Cabling

The following figure shows the internal Ethernet ports and the SAS ports.

Figure 2: Controller ports for internal cabling

 Controller ports for internal cabling 
Legend
1 NET MGT port connects to the cluster interconnect port on the partner Controller (Ethernet). 4 NET 2 port connects to the NET 2 port on the partner Controller(Ethernet).
2 Cluster interconnect network port connects to the NET MGT port on the partner Controller (Ethernet). The cluster interconnect network port is labeled as <- - ->. 5 SAS HBA ports connect between the Controllers and connect the Controllers to the Drive Enclosures (SAS).
3 NET 3 port connects to the NET 1 port on the Pilot node (Ethernet).