Go to main content

SPARC S7-2 and SPARC S7-2L Servers Product Notes

Exit Print View

Updated: October 2020
 
 

prtdiag Not Showing Proper Slot Information for NVMe Drives Connected to MB (23537630)

On SPARC S7-2L servers with a 12 drive backplane, all NVMe drive configuration, prtdiag shows incorrect NAC names for the NVMe drives in slots 3, 4, and 5 as below.

======================================== IO Devices =======================================       
 Slot +            Bus   Name +                            Model      Max Speed  Cur Speed 
 Status            Type  Path                                         /Width     /Width    
-------------------------------------------------------------------------------------------
 ...
 ...
 /SYS/MB/PCIE_SWITCH1 PCIE  nvme-pciexclass,010802       8.0GT/x4   8.0GT/x4   
                          /pci@300/pci@2/pci@0/pci@6/nvme@0            
 /SYS/MB/PCIE_SWITCH1 PCIE  nvme-pciexclass,010802       8.0GT/x4   8.0GT/x4  
                          /pci@300/pci@2/pci@0/pci@7/nvme@0            
 ... 
 /SYS/MB/CMP1/IOS0 PCIX  nvme-pciexclass,010802          8.0GT/x4   8.0GT/x4   
                          /pci@302/pci@2/pci@0/pci@4/nvme@0           
...
...

With correct NAC names for the NVMe drives in slots 3, 4, and 5, prtdiag output would show up as below:

 ======================================== IO Devices =======================================
 Slot +            Bus   Name +                            Model      Max Speed  Cur Speed 
 Status            Type  Path                                         /Width     /Width    
 -------------------------------------------------------------------------------------------
 ...
 ...
 /SYS/DBP/NVME4    PCIE  nvme-pciexclass,010802        8.0GT/x4   8.0GT/x4   
                       /pci@300/pci@2/pci@0/pci@6/nvme@0           
 /SYS/DBP/NVME3    PCIE  nvme-pciexclass,010802        8.0GT/x4   8.0GT/x4   
                       /pci@300/pci@2/pci@0/pci@7/nvme@0           
 /SYS/MB/PCIE5     PCIE  nvme-pciexclass,010802        8.0GT/x4   8.0GT/x4   
                       /pci@300/pci@2/pci@0/pci@15/nvme@0          
 ...
 ...
                    

Workaround: Use the format command or the diskinfo command to find the correct NAC names and associated device paths for the NVMe drives with this configuration. For example, type:

  # diskinfo
			      D:devchassis-path                    c:occupant-compdev
			      -----------------------------------  ------------------
                              /dev/chassis/SYS/DBP/NVME0/disk      c14t1d0           
                              /dev/chassis/SYS/DBP/NVME1/disk      c15t1d0           
                              /dev/chassis/SYS/DBP/NVME2/disk      c16t1d0           
                              /dev/chassis/SYS/DBP/NVME3/disk      c7t1d0            
                              /dev/chassis/SYS/DBP/NVME4/disk      c6t1d0            
                              /dev/chassis/SYS/DBP/NVME5/disk      c13t1d0           
                              /dev/chassis/SYS/DBP/NVME6/disk      c9t1d0            
                              /dev/chassis/SYS/DBP/NVME7/disk      c11t1d0           
                              /dev/chassis/SYS/DBP/NVME8/disk      c12t1d0           
                              /dev/chassis/SYS/DBP/NVME9/disk      c3t1d0            
                              /dev/chassis/SYS/DBP/NVME10/disk     c4t1d0            
                              /dev/chassis/SYS/DBP/NVME11/disk     c5t1d0
                              ...
# format
                              Searching for disks...done

                              AVAILABLE DISK SELECTIONS:
                                  0. c14t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@302/pci@2/pci@0/pci@17/pci@0/pci@4/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME0/disk
                                  1. c15t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@302/pci@2/pci@0/pci@17/pci@0/pci@5/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME1/disk
                                  2. c16t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@302/pci@2/pci@0/pci@17/pci@0/pci@6/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME2/disk
                                  3. c7t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@300/pci@2/pci@0/pci@7/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME3/disk
                                  4. c6t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@300/pci@2/pci@0/pci@6/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME4/disk
                                  5. c13t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@302/pci@2/pci@0/pci@4/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME5/disk
                                  6. c9t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@302/pci@1/pci@0/pci@13/pci@0/pci@4/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME6/disk
                                  7. c11t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@302/pci@1/pci@0/pci@13/pci@0/pci@5/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME7/disk
                                  8. c12t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@302/pci@1/pci@0/pci@13/pci@0/pci@6/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME8/disk
                                  9. c3t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@300/pci@1/pci@0/pci@11/pci@0/pci@4/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME9/disk
                                 10. c4t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@300/pci@1/pci@0/pci@11/pci@0/pci@5/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME10/disk
                                 11. c5t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB>
                                     /pci@300/pci@1/pci@0/pci@11/pci@0/pci@6/nvme@0/disk@1
                                     /dev/chassis/SYS/DBP/NVME11/disk

For additional information about drive errors, see S7-2L 12- and 24-Disk Backplane Systems Unable to Enumerate Disks (18712182).