Skip Headers
Oracle® Enterprise Manager System Monitoring Plug-in Installation Guide for EMC Celerra Server
10g Release 2 (10.2.0.2)

Part Number B28042-03
Go to Documentation Home
Home
Go to Book List
Book List
Go to Table of Contents
Contents
Go to Feedback page
Contact Us

Go to previous page
Previous
PDF · Mobi · ePub

Oracle® Enterprise Manager

System Monitoring Plug-in Installation Guide for EMC Celerra Server

10g Release 2 (10.2.0.2)

B28042-03

October 2009

This document provides a brief description about the Oracle System Monitoring Plug-in for EMC Celerra Server, details on the versions the plug-in supports, prerequisites for installing the plug-in, and step-by-step instructions on how to download, install, verify, and validate the plug-in.

Description

The System Monitoring Plug-in for EMC Celerra Server extends Oracle Enterprise Manager Grid Control to add support for managing EMC Celerra Network Attached Storage (NAS) servers. By deploying the plug-in in your Grid Control environment, you gain the following management features:

Versions Supported

This plug-in supports the following versions of products:

Prerequisites

The following prerequisites must be installed before you can deploy version 2.1.2.0.0 of the plug-in:

Deploying the Plug-in

After you ensure that the prerequisites are met, follow these steps to deploy the plug-in:

  1. Download the EMC Celerra Server Plug-in archive to your desktop or computer on which the browser is launched. You can download the archive from the Oracle Technology Network (OTN).

  2. Log in to Enterprise Manager Grid Control as a Super Administrator.

  3. Click the Setup link in the upper right corner of the Grid Control Home page, then click the Management Plug-ins link on the left side of the Setup page.

  4. Click Import.

  5. Click Browse and select the plug-in archive:

  6. Click List Archive, which lists the plug-ins from the selected archive.

  7. Select the plug-in and click OK.

  8. Verify that you have set preferred credentials on all Agents where you want to deploy the plug-in.

  9. In the Management Plug-ins page, click the icon in the Deploy column for the EMC Celerra Server plug-in. The Deploy Management Plug-in wizard appears.

  10. Click Add Agents, then select one or more Agents to which you want to deploy the plug-in. The wizard reappears and displays the Agent you selected.

  11. Click Next, then click Finish.

    If you see an error message stating that the preferred credential is not set up, go to the Preferences page and add the preferred credentials for the Agent target type.

Adding Instances for Monitoring

After successfully deploying the plug-in, follow these steps to add the plug-in target to Grid Control for central monitoring and management:

  1. From the Agent home page where the EMC Celerra Server Plug-in was deployed, select the EMC Celerra Server target type from the Add drop-down list, then click Go. The Add EMC Celerra Server page appears.

  2. Provide the following information for the parameters:

    • Name — Name for the plug-in

    • Celerra Control Station Host or IP Address — Name/IP address of the Control Station

    • Celerra Admin User — Keep the default name if SSH set up for nasadmin, or change the name if SSH is set up for a different user

  3. Click Test Connection to make sure the parameters you entered are correct.

  4. Reenter the encrypted parameters from step 2 if the connection test was successful, then click OK.

Note:

After you deploy and configure the plug-in to monitor one or more targets in the environment, you can customize the monitoring settings of the plug-in. This alters the collection intervals and threshold settings of the metrics to meet the particular needs of your environment. If you decide to disable one or more metric collections, this could impact the reports that the metric is a part of.

Verifying and Validating the Plug-in

After waiting a few minutes for the plug-in to start collecting data, use the following steps to verify and validate that Enterprise Manager is properly monitoring the plug-in target:

  1. Click the EMC Celerra Server target link from the Agent home page Monitored Targets table. The EMC Celerra Server home page appears.

  2. Verify that no metric collection errors are reported in the Metrics table.

  3. Ensure that reports can be seen and no errors are reported by selecting the Reports property page.

  4. Ensure that configuration data can be seen by clicking the View Configuration link in the Configuration section. If configuration data does not immediately appear, click Refresh in the View Configuration page.

Configuring SSH to Bypass the Password

Follow the steps below to set up SSH from the host, where the Enterprise Manager Agent is installed on the EMC Celerra control station.

  1. Log in to the host where the Enterprise Manager Grid Control Agent is installed that monitors EMC Celerra. Log in as the user under which the Agent is running.

  2. Connect to the EMC Control Station using SSH as shown below. Ensure that the SSH client is installed on the host. If this is the first time you are accessing the Control Station, type Yes when the system asks whether you want to save the RSA key of the Control Station to the local file.

    # ssh -l nasadmin erpcel01-con 
    The authenticity of host 'erpcel01-con (140.20.176.75)' can't be established. 
    RSA key fingerprint is 72:2c:f8:db:76:c9:8d:35:ae:b1:ab:74:30:f5:69:af. 
    Are you sure you want to continue connecting (yes/no)? yes 
    Warning: Permanently added 'erpcel01-con, 140.20.176.75' (RSA) to the list of known hosts. 
    nasadmin@ erpcel01-con 's password: [Type the password for nasadmin] 
    Last login: Sat Oct 15 22:18:21 2005 from stach28.us.oracle.com
    EMC Celerra Control Station Linux Thu Mar 24 08:27:43 PST 2005
    slot_0 primary control station ***  
    [nasadmin@erpcel01-con nasadmin]$ [Type exit and exit SSH]
    
  3. Generate a pair of authentication keys on the Agent host by entering:

    # cd ~/.ssh    
    # ssh-keygen -t dsa -f id_dsa 
               
    Generating public/private dsa key pair. 
    Enter passphrase (empty for no passphrase): [Leave empty] 
    Enter same passphrase again: [Leave empty] 
    Your identification has been saved in id_dsa. 
    Your public key has been saved in id_dsa.pub. 
    The key fingerprint is: 
    e2:24:fa:d2:f9:48:e6:1e:85:7e:86:d1:b5:52:79:fb spanchum@ stach28.us.oracle.com
    
  4. Upload the public key (id_dsa.pub) to the Control Station in the home directory for user nasadmin.

    # scp id_dsa.pub nasadmin@erpcel01-con:~/.ssh/ 
    nasadmin@erpcel01-con's password: [Type the password for nasadmin] 
    id_dsa.pub 100% |*************************************************| 600 00:00 
    
  5. Log in to the Control Station (erpcel01-con) and rename the uploaded file (id_dsa.pub) to the authorized_keys file. If the file already exists, add the contents of the id_dsa.pub file to the authorized_keys file by entering:

    # ssh -l nasadmin erpcel01-con 
    nasadmin@erpcel01-con's password: [Type the password for nasadmin] 
    Last login: Sat Oct 15 22:53:22 2005 from stach28.us.oracle.com
    EMC Celerra Control Station Linux Thu Mar 24 08:27:43 PST 2005
    *** slot_0 primary control station *** 
    [nasadmin@erpcel01-con nasadmin]$ cd .ssh 
    [nasadmin@erpcel01-con .ssh]$ cat id_dsa.pub >> authorized_keys 
    [nasadmin@erpcel01-con .ssh]$ logout 
    Connection to erpcel01-con closed. 
    
  6. Run the following command to verify that a password is not required for any of the secure programs:

    # ssh -l nasadmin erpcel01-con date 
    Sat Oct 15 23:04:46 PDT 2005
    

Configuring EMC Celerra SNMP Traps

The following sections provide the configuration steps to be performed on the EMC Celerra control station to send SNMP traps to the Enterprise Manager EMC Celerra Plug-in. For more information about the EMC Celerra event and notification system, refer to the following EMC-provided documentation:

Celerra Network Server Technical Module — Configuring Celerra Events and Notifications

Configuring the SNMP Trap Configuration File

The SNMP Trap Configuration file specifies the SNMP Manager to which the trap should be sent. To receive SNMP traps from the Celerra Control Station, you can modify the default trap configuration file /nas/site/trap.cfg or create a new configuration file. A different file is required if more than one SNMP manager is listening for different SNMP traps. The SNMP Trap Configuration file is referenced in the Notification Configuration file, which is described in the next section.

If you plan to use the default Notification Configuration file specific to Enterprise manager as described in the next section, you should create a new SNMP Trap Configuration file (em_trap.cfg) by performing the following steps.

  1. Ensure that the prerequisites for SNMP are met. See "Prerequisites".

  2. Log in to the EMC Celerra control station as a NASADMIN user.

  3. Enter:

    cd /nas/site

  4. Enter:

    cp trap.cfg em_trap.cfg

  5. Modify the contents of em_trap.cfg by uncommenting and changing snmpmanager to point to the emagenthost:emagentport format, as shown in the following example:

    snmpmanager 140.87.1.84:5125 ; communityname public

Creating and Loading a Notification Configuration File

The Notification Configuration file specifies the list of events for which notifications are to be sent. The default notification file,/nas/sys/nas_eventlog.cfg, contains all the default notification events with different types of notification methods (call home, SNMP trap, email, log, exec, and so forth).

You can either modify the default notification file,/nas/sys/nas_ eventlog.cfg, or create a new one specific to Enterprise Manager with a subset of events. The following procedure provides a sample Notification Configuration File, em_snmp_eventlog.cfg, which contains power status, fan status, reboot events, and failover events. You can add more events as required. Refer to the EMC-provided documentation, Celerra Network Server Technical Module — Configuring Celerra Events and Notifications, for details on the format of the Notification Configuration file.

Perform the following steps to create and load the file:

  1. Log in to the EMC Celerra control station as a NASADMIN user.

  2. Create the em_snmp_eventlog.cfg file with the following contents:

    #
    # Notification file for Enterprise Manager plug-in for EMC Celerra
    #
    # BoxMonitor
    # Fan status, power status events for CNS-14, Reboot events for  ALL platforms
    facilitypolicy  131, 4
        disposition range=1-1, trap "/nas/site/em_trap.cfg 2"
        disposition range=3-15, trap "/nas/site/em_trap.cfg 2"
        disposition range=18-21, trap "/nas/site/em_trap.cfg 2"
        disposition range=38-39, trap "/nas/site/em_trap.cfg 2"
        disposition range=43-43, trap "/nas/site/em_trap.cfg 2"
        disposition range=57-58, trap "/nas/site/em_trap.cfg 2"
        disposition range=62-67, trap "/nas/site/em_trap.cfg 2"
        disposition range=70-70, trap "/nas/site/em_trap.cfg 2"
        disposition range=73-73, trap "/nas/site/em_trap.cfg 2"
        disposition range=100-115, trap "/nas/site/em_trap.cfg 2"
        disposition range=200-215, trap "/nas/site/em_trap.cfg 2"
        disposition range=300-315, trap "/nas/site/em_trap.cfg 2"
     
    #
    # Enclosure Monitor
    # Fan status, power status events for NS platform
    facilitypolicy 86, 7
        disposition severity=0-3, trap "/nas/site/em_trap.cfg 2"
        disposition severity=4-4, trap "/nas/site/em_trap.cfg 3"
    
  3. Edit the file to add any other events if needed.

  4. Enter the nas_event command as shown in the following example:

    [nasadmin@erpcel01-con site]$ nas_event -Load /nas/site/em_event_config.cfg EventLog : will load /nas/site/em_snmp_eventlog.cfg... done

  5. Verify if the file is loaded by entering the nas_event command as shown in the following example:

    [nasadmin@erpcel01-con site]$ nas_event -Load -info

    Loaded config. files:

    1: /nas/sys/nas_eventlog.cfg

    2: /nas/http/webui/etc/web_client_eventlog.cfg

    3: /nas/jserver/event_config/events.cfg

    4: /nas/site/em_snmp_eventlog.cfg

To map EMC severities (0-7) to Enterprise Manager severities, use the following required Oracle SNMP Enterprise-specific traps:

  • SNMP trap 2 to send critical alerts (EMC-defined severity <= 3)

  • SNMP trap 3 to send warning alerts (EMC-defined severity <= 4)

Sending an SNMP Trap Test

After you deploy the plug-in and set up a target as instructed in the System Monitoring Plug-in Installation Guide for EMC Celerra Server, you can use the nas_snmptrap command to send SNMP trap tests.

  1. Log in to the EMC Celerra control station as a NASADMIN user.

  2. Run the nas_snmptrap command.

    • The syntax of the command is as follows:

      /nas/sbin/nas_snmptrap <config_file_path> -m /nas/sys/emccelerra.mib -r <trap_number> -f <facility_id> -i <event_id> -s <severity_level> -d "<description>"

      <config_file_path> = the path of the trap configuration file /nas/sys/emccelerra.mib = the Celerra MIB file <trap_number> = the unique trap number for the event <facility_id> = the ID number of the facility generating the event <event_id> = the event ID number <event_id> = the event ID number <description> = the description of the trap

    • The following example shows how to send a critical alert:

      /nas/sbin/nas_snmptrap /nas/site/em_trap.cfg -m /nas/sys/emccelerra.mib -r 2 -f 64 -i 2 -s 2 -d "Test SNMP trap Critical Alert"

    • The following example shows how to send a warning alert:

      /nas/sbin/nas_snmptrap /nas/site/em_trap.cfg -m /nas/sys/emccelerra.mib -r 3 -f 65 -i 3 -s 3 -d "Test SNMP trap Warning Alert"

  3. Verify the alerts as follows:

    1. Log in to Grid Control.

    2. Go to the EMC Celerra Target. Under the Reports Tab, view the EMC Celerra SNMP Trap-based Alerts Report. This should list the alert corresponding to the trap test that is sent.

    3. Go to the Grid Control Console Home Page. Under All Targets Alerts, Click the Critical or Warning link. Filter the targets by EMC Celerra Server type. You should see the alert corresponding to the trap test that is sent. You can then select and clear the alert.

Undeploying the Plug-in

Follow these steps to undeploy the plug-in from an Agent:

  1. Log in to Enterprise Manager Grid Control as a Super Administrator.

  2. Select the Targets tab, then the All Targets subtab. The All Targets page appears.

  3. Select the EMC Celerra Server Plug-in target and click Remove. You must do this step for all targets of the plug-in.

  4. Make sure that the preferred credentials are set on the Agents where the plug-in was deployed.

  5. Click the Setup link in the upper right corner of the All Targets page, then click the Management Plug-ins link on the left side of the Setup page. The Management Plug-ins page appears.

  6. Click the icon in the Undeploy column for the EMC Celerra Server Plug-in. The Undeploy Management Plug-in page appears.

  7. Check all the Agents that are currently deployed with the EMC Celerra Server Plug-in and click OK.

    You must undeploy the plug-in from every Agent in the system to completely remove it from the enterprise.

  8. Select the EMC Celerra Server Plug-in on the Management Plug-ins page and click Delete.

Documentation Accessibility

Our goal is to make Oracle products, services, and supporting documentation accessible to all users, including users that are disabled. To that end, our documentation includes features that make information available to users of assistive technology. This documentation is available in HTML format, and contains markup to facilitate access by the disabled community. Accessibility standards will continue to evolve over time, and Oracle is actively engaged with other market-leading technology vendors to address technical obstacles so that our documentation can be accessible to all of our customers. For more information, visit the Oracle Accessibility Program Web site at http://www.oracle.com/accessibility/.

Accessibility of Code Examples in Documentation

Screen readers may not always correctly read the code examples in this document. The conventions for writing code require that closing braces should appear on an otherwise empty line; however, some screen readers may not always read a line of text that consists solely of a bracket or brace.

Accessibility of Links to External Web Sites in Documentation

This documentation may contain links to Web sites of other companies or organizations that Oracle does not own or control. Oracle neither evaluates nor makes any representations regarding the accessibility of these Web sites.

Deaf/Hard of Hearing Access to Oracle Support Services

To reach Oracle Support Services, use a telecommunications relay service (TRS) to call Oracle Support at 1.800.223.1711. An Oracle Support Services engineer will handle technical issues and provide customer support according to the Oracle service request process. Information about TRS is available at http://www.fcc.gov/cgb/consumerfacts/trs.html, and a list of phone numbers is available at http://www.fcc.gov/cgb/dro/trsphonebk.html.


Enterprise Manager System Monitoring Plug-in Installation Guide for EMC Celerra Server, 10g Release 2 (10.2.0.2)

B28042-03

Copyright © 2009, Oracle and/or its affiliates. All rights reserved.

This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reverse engineering, disassembly, or decompilation of this software, unless required by law for interoperability, is prohibited.

The information contained herein is subject to change without notice and is not warranted to be error-free. If you find any errors, please report them to us in writing.

If this software or related documentation is delivered to the U.S. Government or anyone licensing it on behalf of the U.S. Government, the following notice is applicable:

U.S. GOVERNMENT RIGHTS Programs, software, databases, and related documentation and technical data delivered to U.S. Government customers are "commercial computer software" or "commercial technical data" pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As such, the use, duplication, disclosure, modification, and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract, and, to the extent applicable by the terms of the Government contract, the additional rights set forth in FAR 52.227-19, Commercial Computer Software License (December 2007). Oracle USA, Inc., 500 Oracle Parkway, Redwood City, CA 94065.

This software is developed for general use in a variety of information management applications. It is not developed or intended for use in any inherently dangerous applications, including applications which may create a risk of personal injury. If you use this software in dangerous applications, then you shall be responsible to take all appropriate fail-safe, backup, redundancy, and other measures to ensure the safe use of this software. Oracle Corporation and its affiliates disclaim any liability for any damages caused by use of this software in dangerous applications.

Oracle is a registered trademark of Oracle Corporation and/or its affiliates. Other names may be trademarks of their respective owners.

This software and documentation may provide access to or information on content, products, and services from third parties. Oracle Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third-party content, products, and services. Oracle Corporation and its affiliates will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party content, products, or services.