Siebel Consumer Goods Handheld Guide > Deploying Siebel Handheld Applications > Configuring the Siebel Server for Direct Server Synchronization   >

Configuring Logging Levels for Direct Server Synchronization


To set the logging level, you need to perform the following two tasks:

You set the logging level to a value between 1 and 5 as shown in Table 21.

Table 21. Logging Levels
Logging Level
Results

1

Error listing

2

Warning listing

3

Information listing, including SQL tracing

4

Information listing

5

Debug

To configure Siebel Server logging levels

  1. Log into Server Manager from a (m:\siebel\bin\w32ud) prompt.
  2. Run the following:

    change evtloglvl HandheldSyncLog=[LogLevel] for comp [OMName], where [LogLevel] = an integer between 1 - 5 (5 enables all logging) and [OMName] = the OM name (for example, <ApplicationName>CEObjMgr_enu)

To configure Siebel Server logging levels using the Server Configuration screen

  1. Navigate to Administration - Server Configuration screen > Servers view > Components view tab.
  2. In the Component list, query for the appropriate component, such as Handheld Sales CE (ENU).
  3. In the Events list, search for the event type Handheld Sync Logging.
  4. Set the value to a number between 1-5 and then save the change.

    See Table 21 for logging level results.

NOTE:  To enable Object Manager logging, add ObjMgrSqlLogLevel to the PDA section of your Siebel Handheld application's CFG file. Valid values range from 1-5 as described in Table 21.

Siebel Consumer Goods Handheld Guide Copyright © 2007, Oracle. All rights reserved.