Siebel Field Service Guide > Assets > Administration - Product Screen >

Product Measurements View


The Product Measurements view defines measurements that may be obtained from specific assets. Table 123 describes items in product measurements records.

Table 123.  Selected Items in the Product Measurements View
Item
Description

Maximum

The largest possible value for the measurement device.

Minimum

The smallest possible value for the measurement device.

Upper Limit

The upper control limit for readings. This is less than or equal to the Maximum.

Lower Limit

The lower control limit for readings. This is greater than or equal to the Minimum.

Use Plan Bill Method

The method of accumulating data from readings, chosen from a list:

  • Incremental. Counter increments continuously with each reading.
  • Absolute. Counter is set to a predetermined minimum or zero after each reading.

Use Basis (Days)

The time period, in days, over which the expected use is to occur.

Upper and lower limits for readings may indicate threshold or trigger values for an asset. For example, exceeding an upper limit could trigger a preventive maintenance action.

Measurements associated with a product are not automatically associated with assets of the product.

Siebel Field Service Guide