Siebel Server Sync Guide > Configuring Siebel Server Sync >
Verifying SSSE Component Definitions
SSSE uses two server components, PIMSI Engine and PIMSI Dispatcher. The following procedure describes how to configure these components correctly. This task is a step in Process of Configuring SSSE. To verify server component definitions
- From the Siebel application menu, choose Navigate > Site Map > Administration - Server Configuration > Enterprises > Component Definitions.
- In the Component Definitions list, use standard query techniques to locate records where Component matches PIMSI*.
- If records exist with aliases of PIMSIEng or PIMSIDispatcher, select these records and click Delete.
- In the Component Definitions list, click New to create a new record, and complete the fields as described in the following table.
|
|
Component |
PIMSI Dispatcher |
Alias |
PIMSIDispatcher |
Component Type |
PIMSI Engine Service (with Batch as the Runtime value) NOTE: Once the record is saved, this value automatically changes to Business Service Manager.
|
Component Group |
PIM Server Integration Management |
- With the PIMSI Dispatcher record selected in the Component Definitions list, set the following values in the Component Parameters list:
For more information about the Maximum Tasks parameter, see About Tuning SSSE for Optimal Performance.
|
|
Business Service Name |
PIMSI Engine Service |
Method Name |
GenerateExtractReqMsgs |
Maximum MT Servers |
1 CAUTION: If Maximum MT Servers is set to a greater value than 1, unpredictable results may occur.
|
Maximum Tasks |
10 |
Key Based Enabled |
TRUE |
Application Repository File |
- For Siebel Business Applications, enter siebel.srf
- For Siebel Industry Applications, enter siebel_sia.srf
|
- In the Component Definitions list, click New to create a new record, and complete the fields as described in the following table.
|
|
Component |
PIMSI Engine |
Alias |
PIMSIEng |
Component Type |
PIMSI Engine Service (with Batch as the Runtime value) NOTE: Once the record is saved, this value automatically changes to Business Service Manager.
|
Component Group |
PIM Server Integration Management |
- With the PIMSI Engine record selected in the Component Definitions list, set the following values in the Component Parameters list:
|
|
Business Service Query Access |
SSSE Address Parser (eScript) |
Business Service Name |
PIMSI Engine Service |
Method Name |
BusSvcMgrInit |
Maximum MT Servers |
1 |
Maximum Tasks |
10 |
Application Repository File |
- For Siebel Business Applications, enter siebel.srf
- For Siebel Industry Applications, enter siebel_sia.srf
|
NOTE: The Siebel database and Exchange differ in how they store addresses. The Business Service Query Access parameter specifies the name of the script that will be used to combine two Siebel address field values when transmitting address data to Exchange, and split one Exchange address field value into two values when transmitting address data to the Siebel database.
- From the Siebel application menu, choose Navigate > Site Map > Administration - Server Configuration > Enterprises > Component Definitions.
- In the Component Definitions list, use standard query techniques to locate records where Component matches PIMSI*.
- For each of the components PIMSIDispatcher and PIMSIEng, select the component record, and then click Enable.
- In the Component Definitions list, select PIMSIDispatcher and PIMSIEng, and then click Synchronize.
- When synchronization is complete, verify that the PIMSI Dispatcher component and the PIMSI Engine component exist.
- On the machine that hosts the PIMSI Dispatcher component, restart the Siebel Server.
For information about restarting Siebel Servers, see Siebel System Administration Guide.
- On the machine that hosts the PIMSI Engine component, restart the Siebel Server.
|