Most recent revision: June 7, 2007

 


About BEA AquaLogic Data Services Platform

AquaLogic Data Services Platform™ provides read and write access to information in relational databases, Web services, Java functions, XML files, delimited files, and other types of disparate data.

Once developed, application developers — using access technologies such as the AquaLogic Data Services Platform mediator API, JDBC, SQL, or AquaLogic Data Services Platform controls — can invoke AquaLogic Data Services Platform functions as a means of providing their applications with access to integrated, updateable data from their enterprise.

Metadata, security, and cache management facilities are provided through the Data Services Platform Console (ldconsole).

Note: BEA AquaLogic Data Services Platform was originally named Liquid Data for WebLogicŪ. Some artifacts of the original name such as `ld' remain in the product, path, and other artifacts.

Revision Policy

Release Notes are subject to revision between releases. The most recent version can always be found at:

http://download.oracle.com/docs/cd/E13167_01/aldsp/docs25/relnotes/index.html

Items modified or added post-release are so marked and dated.

This document includes the following topics:

 


What's New in AquaLogic Data Services Platform 2.5

AquaLogic Data Services Platform version 2.5 adds a number of new features to AquaLogic Data Services Platform. Table 1 list many of these features.

Table 1 New and Improved Functionality in AquaLogic Data Services Platform Version 2.5
Feature
Details
Integration with AquaLogic Service Bus
Integration is provided to allow AquaLogic Service Bus users to leverage AquaLogic Data Services Platform for read/write database and other data source connectivity. Capabilities include:
  • Allowing custom AquaLogic Service Bus Transport to invoke data services directly.
  • Allowing data services to be invoked using RMI (thus avoiding Web services communication issues).
  • Preserving the security context during communication between services.
9.2 Client Support
Add support for WebLogic 9.2 clients in two areas:
  • Workshop controls
  • Mediator API
Excel Add-in
Provides on-demand query services and Excel reporting capabilities for moderately-sized data sets are involved. Specific features include:
  • Ability to invoke AquaLogic Data Services Platform-generated Web services within Microsoft Excel.
  • Data service data post-processing.
  • Secured Web service invocation.
  • Ability to schedule report refreshes.
JDBC Driver Enhancements
The AquaLogic Data Services Platform JDBC driver and associated tooling has been enhanced. Specifically:
  • Driver is more fully based on the 3.0 JDBC specification.
  • SQL-92 syntax is more fully supported.
  • Data streaming through the JDBC driver is more fully supported for large result sets.
  • The latest version of major reporting tools such as Crystal Reports, BusinessObjects, and Hyperion have been successfully tested.
Extending Tooling to Support SQL
A number of tooling enhancements have been made to provide enhanced support for SQL in two key areas:
  • Accessing SQL through data services.
  • Allowing SQL reporting tools to better access information under data service management.
Specific new functionality includes:
  • Ability to publish data services as JDBC artifacts, with refactoring support.
  • Ability to create substitutions for generated SQL statements. This makes it possible for administrators to post-edit generated SQL for the limited purpose of providing database hints and so forth.
  • Standalone query plan viewer supporting both XQuery and SQL
JDBC Metadata Access Control
Allows use of the AquaLogic Data Services Platform console to secure metadata for:
  • SQL objects, which can be made invisible to the JDBC driver or
  • Data hiding, where the fields are visible, but the data is hidden to the unauthorized user.

 


Supported Configurations  

As a WebLogic Workshop application, AquaLogic Data Services Platform generally supports the same platforms, operating systems, processor architecture, SDKs, and RDBMS systems as does supported servers, as described under WebLogic Server and Client Support.

Note: For details on post-release testing of other operating systems, SQL databases, JDBC drivers, and Web services see the online version of these Release Notes:
http://download.oracle.com/docs/cd/E13167_01/aldsp/docs25/relnotes/relnotes.html
Note: The minimum RAM recommendations are for supporting a single instance of WebLogic Server on which AquaLogic Data Services Platform is running. You may need more memory if you run two or more instances of WebLogic Server and AquaLogic Data Services Platform. Some systems use disk space as virtual RAM. Performance when running in virtual RAM may be markedly slower than when running in physical RAM.

The following abbreviations are used in this section:

Table 2 Testing Classifications
Classification
Meaning
TESTED
Tested.
SUPPORTED
Not specifically tested, but should work.
NS
Not supported.

WebLogic Server and Client Support

A supported version of WebLogic Platform 8.1 is needed for development and runtime (client). The following table (Table 3) details WebLogic server and client support.

Table 3 AquaLogic Data Services Platform 2.5 WebLogic Platform and Client Support
Component
Platform
JDK
Testing Status
Platform Server
WebLogic 8.1 SP4
Java HotSpot VM 1.4
SUPPORTED
 
JRockit 1.4
SUPPORTED
 
WebLogic 8.1 SP5
Java HotSpot VM 1.4
TESTED
 
JRockit 1.4
TESTED
 
Weblogic 8.1 SP6
Java HotSpot VM 1.4
TESTED (10/2006)
 
JRockit 1.4
TESTED (10/2006)
 
WebLogic 9.x
Java HotSpot VM 1.5
NS
 
Jrockit R26.0.0
NS
Client
WebLogic 8.1 SP4
Sun JDK 1.4
SUPPORTED
 
JRockit 1.4
SUPPORTED
 
WebLogic 8.1 SP5
Sun JDK 1.4
TESTED
 
JRockit 1.4
TESTED
 
Weblogic 8.1 SP6
Java HotSpot VM 1.4
TESTED (10/2006)
 
JRockit 1.4
TESTED (10/2006)
 
WebLogic 9.x
Sun HotSpot VM 1.5
TESTED
 
JRockit R26.0.0
TESTED

Supported Development and Client Configurations

For data service development a complete installation of a supported version of WebLogic Platform 8.1 is recommended. The following chart lists tasks associated with data service development and deployment and the minimal platform component installations.

(For the purposes of this table ALDSP stands for AquaLogic Data Services Platform; WLS stands for WebLogic server.)

Table 4 Supported Server/Platform Configurations for Development and Runtime
Activity
Minimal Configuration
ALDSP development under WLS 8.1 SP5 or SP6
ALDSP-enabled WLS 8.1
ALDSP development under WLS 8.1 SP4
ALDSP-enable WLS 8.1 + WebLogic Workshop
ALDSP client access
ALDSP-enabled WLS 8.1
ALDSP development and specific WebLogic Platform 8.1 components
ALDSP-enabled WLS + the same specific WebLogic Platform 8.1 components
RTLApp (sample ALDSP application)
WebLogic Platform 8.1

Supported Operating Systems and Hardware

The following table (Table 5) lists operating systems and/or hardware that are supported for this release. Testing Status indicates when testing has occured. Test criteria is defined in Table 2.

Platforms and versions in boldface (also with gray backgrounds on PDF pages) support both design time (data service development through WebLogic Workshop IDE) and runtime. Others support runtime only.

Platforms not specifically listed are not supported.

Table 5 Platform and Platform Version Support for AquaLogic Data Services Platform
Operating System
Platform
Version
Hardware
Testing Status
Microsoft Windows
Windows Server 2000
2000, 2003
x86
TESTED
 
Windows XP
XP
x86
TESTED
UNIX
HP-UX
HP-UX 11i
PA-RISC
TESTED
 
Sun Solaris
8, 9, 10
SPARC64
TESTED
   
10
x86
TESTED (10/2006)
 
IBM AIX
5.2, 5.3
pSeries
TESTED (10/2006)
Linux
Red Hat Enterprise Linux
3.0, 4.0
x86
TESTED
   
4.0
64-bit Xeon/AMD64 (32-bit JVM)
TESTED
 
Novell SuSE Linux Enterprise Server
9
x86, 64-bit Xeon/AMD64 (32-bit JVM)
TESTED (10/2006)

Supported Relational Database Management Systems

In general any thread-safe, transaction-callable relational database management system (RDBMS) accessible through JDBC should be available to AquaLogic Data Services Platform.

Several vendor-specific levels of support are provide, as shown in Table 6.

Table 6 Vender-specific Levels of RDBMS Support
Support Level
Description
Extended
The specific database version has been tested and found to be compatible with AquaLogic Data Services Platform. Extended support means that support is provided for stored procedures and some database functions. See Table 7 for full details on vendor and version support.
Tested
The specific database version has been tested and found to be compatible with AquaLogic Data Services Platform. Some operations may be pushed down to the database level. Tested support is provided for such vendors as Informix, MySQL, and Microsoft Access.
Generic
Although the particular database versions has not been tested, basic SQL read and write calls should work if the database supports JDBC standards. Generic support is sometimes referred to as base support.

Databases which have been tested with AquaLogic Data Services Platform 2.5 are listed in Table 7. Subsequent versions of particular DBMS systems should work to the same level of support, but have not been specifically verified.

Table 7 RDBMS Support in AquaLogic Data Services Platform 2.5
Database
Version(s)
RDBMS Support Level
Tested?
Supported?
Caching
Support for
Vendor
Oracle
10g
9i
8.1.7
RAC
EXTENDED
EXTENDED
EXTENDED
EXTENDED
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
IBM DB2
8.1
EXTENDED
Yes
Yes
Yes
Sybase
12.5 or prior
12.5.2 and above
GENERIC
EXTENDED
No
Yes
Yes
Yes
Yes
Microsoft SQL Server
SQL Server 7
2000
SQL Server 2005
EXTENDED
EXTENDED
EXTENDED
No
Yes
No
Yes
Yes
Yes
Yes
Informix
IDS with Universal Data Option (9.2 and above)
IDS 9.3
IDS 9.4
GENERIC

GENERIC
GENERIC


No
Yes
No


Yes
Yes
Yes
No
Teradata
V2r4.1.3,
v2r5.1.x
v2r6.0
GENERIC
GENERIC
GENERIC
No
Yes
No
MS Access
2000
GENERIC
Yes
Yes
No
MySQL
4.1.14
5
GENERIC
GENERIC
Yes
Yes
Yes
Yes
No
Other DBMS systems
Any
GENERIC
No
No
No
PointBase
4.41
EXTENDED
Yes
Yes1
No

1PointBase Server is an all-Java DBMS product included with WebLogic Platform 8.1 distribution solely for evaluation purposes, either in the form of custom trial applications or through packaged sample applications provided with WebLogic Platform. Non-evaluation development or other use of the PointBase Server requires that a separate PointBase Server license be obtained directly from DataMirror. AquaLogic Data Services Platform does not support PointBase for production server deployments.

Supported Database-JDBC Driver Matrices

The following table (Table 8) describes results of testing AquaLogic Data Services Platform against various databases under different JDBC drivers. Both the BEA and native drivers were tested in XA and non-XA modes. Limitation encountered are noted as CR numbers in the Comments column.

Table 8 Matrices of Databases and JDBC Drivers Supported by AquaLogic Data Services Platform
Database
JDBC Driver Type
Data Source Type
Comments
Oracle
BEA non-XA
tables
CR199675
   
stored procedures
CR202963 CR212515
 
BEA XA
tables
CR199675
   
stored procedures
CR202963 CR212515
 
Oracle non-XA
tables
CR265965
   
stored procedures
CR212515 CR202962
 
Oracle XA
tables
 
   
stored procedures
 
IBM DB2
BEA non-XA
tables
 
   
stored procedures
CR227440
 
BEA XA
tables
 
   
stored procedures
CR227440
 
DB2 non-XA
tables
 
   
stored procedures
CR227440
 
DB2 XA
tables
CR227486
   
stored procedures
CR227440
Sybase
BEA non-XA
tables
 
   
stored procedures
 
 
BEA XA
tables
 
   
stored procedures
 
 
Sybase non-XA
tables
CR223429
   
stored procedures
 
 
Sybase XA
tables
CR223429
   
stored procedures
 
Informix
BEA non-XA
tables
CR211701
   
stored procedures
not supported
 
BEA XA
tables
 
   
stored procedures
not supported
 
Native non-XA
tables
CR223486 CR226171
   
stored procedures
not supported
 
Native XA
tables
 
   
stored procedures
not supported
MS-SQL Server
BEA XA
tables
 
   
stored procedures
 
 
MS-SQL Server non-XA
tables
CR214730
   
stored procedures
CR202041
 
MS-SQL Server XA
tables
 
   
stored procedures
 

Details related to these CR numbers can be found in Product Limitations and Workarounds.

Configuring the AquaLogic Data Services Platform JDBC Driver for Reporting Tools

The following table (Table 9) describes the matrices for configuring the AquaLogic Data Services Platform JDBC driver for supported reporting applications.

Note: In cases where the reporting tool supports JDBC connectivity, use the AquaLogic Data Services Platform JDBC driver.
Table 9 Matrices of Required Connectivity Software for Reporting Applications Supported by the AquaLogic Data Services Platform JDBC Driver
Application and Version
JDBC Native
OpenLink ODBC/JDBC Lite Bridge
Crystal Reports XI
TESTED
 
Business Objects XI, Release 2
 
TESTED
Hyperion BI 9+, Interactive Reporting
 
TESTED
MS Access 2000
 
TESTED
MS Excel
 
TESTED

Supported Web Services Standards

The following table (Table 10) lists Web services standards supported by AquaLogic Data Services Platform 2.5.

Table 10 Supported Web Services Standards
Web Services Standard
Version
SOAP
1.1
WSDL
1.1
JAX-RPC
1.0

 


Product Limitations and Workarounds

This section contains a table (Table 11) which lists known limitations associated with the current BEA AquaLogic Data Services Platform 2.5 release that users might encounter. Information regarding these limitations includes a CR (change request) number for each problem, applicable platform, a detailed description of the problem and workarounds, where applicable.

Limitations added to this list post general release availability are identified by date as well as CR number.

Please contact BEA customer support at:


http://support.bea.com

for assistance in tracking unresolved issues.

Table 11 Known Product Limitations and Possible Workarounds
Topic
Details
CR265965
(revised Feb. 2, 2007)
Updating or deleting Oracle's CHAR/NCHAR with trailing blanks failed using Oracle JDBC driver.
Description
With Oracle's non-XA JDBC driver, CHAR and NCHAR columns can only be updated if the number of characters is 1024 or less. The following message typically appears if this problem occurs:
java.sql.SQLException: ORA-01461: can bind a LONG value only for insert into a LONG column
Platform
All, using Oracle's non-XA JDBC driver.
Workaround
Whenever possible use BEA's Oracle JDBC driver (Type 4).
CR294861
(Oct. 22, 2006)
An exception occurs if a timestamp with time zone is fetched before LONG_RAW.
Platform
All using Oracle.
Description
When using an Oracle database, if a timestamp with a time zone is fetched before a LONG_RAW a "... Stream has already been closed" exception occurs. This is consistent with the way Oracle handles LONG_RAW fetched before blob and clob.
Workaround
Reverse the fetch order of timestamp with time zone and LONG_RAW when using Oracle.
CR293244
(Sept. 30, 2006)
When executing a SQL query containing a single parameter through the AquaLogic Data Services Platform JDBC driver, a "wrong parameter type" occurs.
Platform
All.
Description
When a SQL query is executed, a parameter list containing one and only one parameter is treated as a table parameter instead of a normal parameter, resulting in an exception being returned.
Workaround
Create a SQL table with a single row contain the parameter value and pass that table parameter to the query. For detailed informations on table parameter s and creating a TableParameter class object see the topic "Table Parameter Support" in the Using SQL to Access Data Services chapter of Application Developer's Guide.
CR292297
Importing two or more procedures that have the same return type into an existing data service may not succeed.
Platform
All.
Description
An exception can occur when importing multiple data service procedures, if two or more of the procedures have the same return type.
Workaround
Import procedures having the same return type using separate import operations.
CR292585
When publishing a WSDL generated from AquaLogic Data Services Platform to the AquaLogic Service Registry, multiple entries may appear for the same WSDL.
Similarly, when configuring a Web service from the AquaLogic Service Registry through the Excel Add-in, multiple entries for the same WSDL may be seen.
Platform
All.
Description
When a JWS is generated, by default the form-get and form-post flags are set to True. This setting in conjunction with the absence of a source directive (CR268183) cause multiple entries to appear.
Workaround
Using the Property Editor in WebLogic Workshop, set the form-get and form-post flags to False. Then, if the goal is to generate a WSDL for Excel Add-in use, the following entry should first be placed at the beginning of the comments in the JWS source file:
* @editor-info:link autogen-style="stateless" source="<jcxfilename>.jcx" autogen="true"
CR286359
When importing or synchronizing metadata with an Oracle database, the native width of float elements may be incorrectly calculated.
Platform
All, using the BEA Oracle JDBC driver.
Description
When importing or synchronizing metadata with an Oracle data source, the width of float elements may be rendered incorrectly (15 instead of 6 or 9). This problem has been observed when using the WebLogic JDBC Oracle driver (version 3.0.5.0).
Workaround
Metadata synchronization using Oracle's native JDBC driver (Oracle.jdbc.driver.OracleDriver) did not exhibit this problem. Therefore, if the width of native float elements is an issue use the Oracle JDBC driver.
CR292429
When working with DSP Transport in the AquaLogic Service Bus Console while using a multibyte character set (such as Japanese), unexpected characters may appear in editing fields.
Platform
All.
Description
When using the AquaLogic Service Bus Console in conjunction with a DSP Transport Configuration, if the Request Encoding field or the Response Encoding field is set to utf-8 (the default value) unexpected characters may appear in editing fields when using multibyte character sets.
Workaround
When editing any field in a DSP Transport Business Service configuration, if the request encoding or response encoding should be any value other than the default (utf-8), the setting must be reset to their correct values before saving the configuration.
CR288104
AquaLogic Data Services Platform functions accessed through a 9.2-level Data Service control via a Java Web service may not successfully execute.
Platform
All.
Description
This problem can occur due to differences in the way Web service templates are generated under WebLogic 8.1 and Weblogic 9.2 The template that is generated by a WebLogic Service 9.2 test browser expects a qualified schema and therefore adds namespace prefixes to all elements in the schema. For details see: CR288104 Details.
By contrast, the schema associated with the WebLogic 8.1-level data service does not have elementFormDefault set, so it defaults to unqualified. However, the WebLogic 9.2 Web service sends a qualified xml fragment, causing an error when the schema is passed to the AquaLogic Data Services Platform server running under WebLogic 8.1.
Workaround
Users working with Weblogic 9.2-level Web services should replace the template generated by the WebLogic 8.1 test browser with the template generated by the WebLogic 9.2 test browser. Alternatively, generated code can be edited to include the XMLBean values in the method before passing it to the AquaLogic Data Services Platform control method.
CR292257
Duplicate names are allow when mapping stored procedures to data services during metadata import.
Platform
All.
Description
The SQL name mapping user interface may allow more than one stored procedure with the same name to be configured under the same schema. However, if more than one stored procedure with the same name is configured, the user will see unexpected results in the JDBC metadata API and on execution of the procedures via JDBC.
Workaround
In the Publish Data Service Functions for SQL Use wizard, manually rename stored procedures so that there are no duplicate names.
CR269337
Undetected classname collisions in a Workshop application can cause compilation errors.
Platform
All.
Description
This problem can occur when compiling schema files into SDOs using AquaLogic Data Services Platform. If an element or attribute has the same name (such as `sequence') as an SDO reserved method (such as `getSequence( )'), SDO will — through the XMLBean Java code generator — attempt to "uniqueify" the method by generating `getSequence2', as an example.
Here is a list of SDO keywords which could contribute to such name collision conditions:
  • getBoolean, getByte, getChar, getDouble, getFloat, getInt, getLong, getShort, getBytes, getBigDecimal, getBigInteger, getDataObject, getDate, getString, getList, getSequence
  • setBoolean, setByte, setChar, setDouble, setFloat, setInt, setLong, setShort, setBytes, setBigDecimal, setBigInteger, setDataObject, setDate, setString, setList, setSequence
Workaround
To use the uniqueified name:
  • Add a copy of sdo.xsdconfig to your schema project and
  • In your Java file correct the entry to the uniqueified name as in:
    addrLine.setSequence2(1);
CR291781
Excel Add-in will initially attempt to reuse HTTP basic authentication login credentials for all Web services hosted on the same port.
Platform
All.
Description
In cases where multiple Web services are configured in a single Excel worksheet, and these Web services are hosted by the same host machine and port number, the Excel Add-In will initially attempt to reuse the previously accepted username/password for these services.
If the username/password is not valid for a particular Web service, a login dialog will be displayed. Subsequent Web service invocations during the same Excel session will use the correct login information for each service.
Workaround
No action has to be taken, unless it is not deemed acceptable that an attempt is made to authenticate a web service call initially with incorrect credentials.
In such cases Web services requiring different credentials should be grouped in different servers OR Web services requiring different credentials hosted on the same host/port should be used on separate Excel worksheets.
CR291062
When using AquaLogic Data Services Platform with AquaLogic Service Bus, `dsp' is not supported for inbound transport.
Platform
All.
Description
A null pointer exception occurs if you choose dsp type when creating a proxy service in AquaLogic Service Bus. This is because the data service option erroneously appears in the list of available transport types for this kind of operation.
Workaround
Avoid selecting the dsp type from available options when creating a proxy service in AquaLogic Service Bus.
CR290239
Several underlying WSDL Element definition attributes and Attribute definition attributes are not currently supported in the AquaLogic Data Services Platform Excel Add-in.
Platform
All.
Description
The following Element definition attributes are currently unsupported:
  • substitutionGroup
  • default
  • fixed
  • form
  • abstract
  • block
  • final
The following Attribute definition attributes are currently unsupported:
  • default
  • fixed
  • form
  • abstract
  • block
  • final
Workaround
Any WSDL containing the definition attributes listed above may not function as expected. If problems are encountered, remove these definition attributes from your WSDL.
CR290041
For data service files that are large and slow to compile, you may need to adjust the compiler.delay flag to improve response time during source editing.
Consecutive key strokes during source editing are batched into a single compile event. If file compilation is slow, then you may want to adjust the time window for batching key strokes for compilation.
Platform
All.
Description
When editing large files in Source View, editing during compilation may cause multiple compilations to occur.
Workaround
Adjust the compiler.delay environment variable (in milliseconds) to increase the delay between compilations when doing editing. This property should be specified in the workshop.cfg file as a `-D' parameter.
CR285121
When creating a Data Service control under WebLogic 9.2, an error can occasionally occur if the editor of the Server View is open at the same time.
Platform
All.
Description
When generating or editing a Data Service control on Weblogic 9.2, it is recommended that the editor of the Server View not be open.
Workaround
When generating or editing a Data Service control, if you need to test the JWS, use the:
 Run as Arrow symbol Run on Server
option on the right click menu. This option deploys/undeploy the user component.
If, in rare cases, the control fails to undeploy, then access the Web-based Weblogic administration console and perform the required operation from there.
If the aforementioned editor is already open and you want to edit/generate a Data Service control, first close the editor and then restart WebLogic Workshop.
CR284995
Exception when publishing a WSDL from a data service when an underlying schema does not have a targetNamespace defined.
Platform
All.
Description
An exception indicating that you cannot map a prefix when no namespace is present may occur when attempting to generate a WSDL file from a valid data service.
This is due to the fact that one or more schemas that are depended upon by the data service do not have a targetNamespace defined.
Workaround
Make sure that all schemas underlying your data service have a proper targetNnamespace defined.
CR284834
When accessing data from Informix, use the Informix native JDBC driver when possible.
Platform
All using Informix database systems.
Description
The WebLogic Informix JDBC driver is less performant than the native Informix JDBC driver when accessing data through AquaLogic Data Services Platform.
Workaround
No workaround necessary, but for best performance with Informix data use its native JDBC driver.
CR284534
(updated: 7 June 2007)
Unclear exception message when using a Data Service control with WebLogic 9.2.
Platform
All.
Description
When using a Data Service control with Weblogic 9.2, if the wls90interop.jar that is required to be on the AquaLogic Data Services Platform Top level is not used correctly, a runtime exception may occur. The exception will appear similar to:
weblogic.rjvm.PeerGoneException: ; nested exception is: java.io.EOFException
Workaround
If you see such an exception, check the ALDSP 2.x server log. If an error such as the following appears:
java.io.InvalidClassException: javax.xml.namespace.QName; local class
incompatible: stream classdesc serialVersionUID = 4418622981026545151, local class serial VersionUID = -9120448754896609940
then the cause of this error is likely due to one of the following:
  • the wls90interop.jar file is not in the ALDSP 2.x server classpath
  • the wls90interop.jar file is not listed first in the classpath.
CR279492
When using a data service based on a Web service at runtime, a validation error may occur if form and/or elementFormDefault do not match. This happens because redefinition of the `Form' attribute is not supported.
Platform
All.
Description
At design time, if:
  • The elementFormDefault attribute in the primary schema does not match the elementFormDefault attribute in an imported or included schema, or
  • if the form attribute of an element does not match the elementFormDefault attribute in the primary schema.
then, at runtime, validation errors will occur when accessing Web service-based data services.
Workaround
The elementFormDefault in the primary schema and any imported or included schemas should match prior to compilation. Also, the form attribute of the element should match the elementFormDefault in the primary schema.
CR288384
The Data Lineage feature in AquaLogic Data Services Platform administration console requires the X11 graphical environment in Linux and UNIX environments.
Platform
UNIX and Linux.
Description
The following error:
"java.lang.NoClassDefFoundError: sun/awt/X11GraphicsEnvironment"
may occur while accessing the Data Lineage feature of AquaLogic Data Services Platform Administration Console. The circumstances arise when the Administration Server hosting AquaLogic Data Services Platform Administration Console is running on a Linux or UNIX host with one of the following conditions (not an exhaustive list):
  1. A headless environment is in use — for example, without monitor and/or X server.
  2. With a monitor, but the user running the administration server is not the same user logged-in from the monitor, and therefore, does not have display permissions to the default display (:0.0).
Workaround
To resolve this issue, set the headless property to true:
-Djava.awt.headless=true
in the Weblogic Server startup script (startWeblogic.sh) in the section of the script where the server is started.
CR283262
Unable to add criteria to SQL when using MS Excel with EasySoft or OpenLink.
Platform
All.
Description
In Microsoft Query, adding a query criteria using the Add Criteria window, (Criteria Arrow symbolAdd Criteria) throws an error message when accessing AquaLogic Data Services Platform data sources.
Workaround
To workaround this issue:
  1. In the Microsoft Query window, select the Records menu option. If the Automatic Query option is checked, then clear this option.
  2. Click ViewArrow symbolCriteria. This will add a Criteria window to the query window into which you can enter appropriate criteria.
  3. To execute query with the criteria added, click Records Arrow symbolQuery Now.
CR270188
Cannot use the WLS Administration Console to define a security policy for accessing the AquaLogic Data Services Platform Console.
Description
If a user defines a security policy in WebLogic admin console for AquaLogic Data Services Platform console (ldconsole.ear), only the user in the Administrator role can access/login to the AquaLogic Data Services Platform console. Other read-only roles (Operator, Monitor, Deployer) fail to access to AquaLogic Data Services Platform console, instead returning the error:

Authentication Denied
The username or password has been refused by WebLogic Server.

Platform
All.
Workaround
By default ldconsole is allowing access ONLY to administrator group. Only when security policy is defined, are other users allowed per defined security policies.
The operation can be completed using the following steps:
  1. Log in to the WLS console with admin credentials.
  2. Created a new user (such as JACK_BLACK).
  3. Assigned the user to the Monitors group.
  4. Log out of the WLS console.
  5. Log in to ldconsole in the Admin role.
  6. Edit security settings in the AquaLogic Data Services Platform metadata browser to add a security policy allowing read access to users of group "Monitors".
  7. Log in to the ldconsole page using the JACK_BLACK user credentials.
CR233032
Under some conditions a data service project deployment fails with an error similar to:

Deployment failed, Last Message from the server ...

Description
Under some conditions the weblogic-application.xml can become corrupted when deploying a AquaLogic Data Services Platform-enabled application, leading to a AquaLogic Data Services Platform deployment failure.
Platform
All.
Workaround
A software patch is available at:
<weblogic_home>/liquiddata/platform_patches/81SP4/CR233032
Alternatively, performing a Clean operation before a project Build automatically repairs the file:

weblogic-application.xml

CR267820
Metadata synchronization update preview displays "Problem in parsing XML fragment" error.
Description
If your project contains Java function signatures referring to XMLBeans, then erroneous results may be reported when doing a metadata update.
Platform
All.
Workaround
Delete the <project.jar> file in your application's library folder that was created when you last built your project. Then synchronize and rebuild.
CR264597
String comparison operations involving MS-SQL may return incorrect results when the comparison operation is computed by MS-SQL.
Description
Platform
All.
Workaround
CR253530
When importing AquaLogic Data Services Platform projects into Workshop if the option Copy into Application Directory is not selected, importing a project not already located in the application results in `resource not found' errors.
Description
AquaLogic Data Services Platform requires that projects be contained in the application folder. This is handled automatically if the Copy into Application Directory option in Workshop is selected.
Platform
All.
Workaround
Select the Copy into Application Directory option when importing AquaLogic Data Services Platform Console projects.
CR204243
When casting xs:decimal from an xs:integer or xs:long, resulting values may not be precisely correct.
Description
As above.
Platform
All.
Workaround
To avoid the possibility of an incorrect result use a string literal instead of an xs:integer literal. For example instead of:
xs:decimal( 9223372036854775807 )
use:
xs:decimal( "9223372036854775807" )
CR260587
An exception during an SDO update operation can occur if the order of elements in the client diffgram is changed and the Validate option is active.
Description
Sometimes the order of elements in a diffgram changes, potentially leading to datagraph validation failure.
Platform
All, using ADO.NET clients.
Workaround
If possible, turn off validation for the operation.
CR268183
Workshop removes a necessary line when editing an AquaLogic Data Services Platform Control-generated JWS file.
Description
After creating a AquaLogic Data Services Platform control it may be necessary to edit the generated JWS file. For example, in the case of enabling Web service security, the user may need to modify the JWS property that specifies a Web service security file.
If the JWS is edited in Workshop, a line in the header beginning:
* @editor-info:link autogen-style ...
is automatically removed. This line is needed in order to generate ADO.NET-enabled WSDL files.

Note: This problem also affects the Excel Add-in.

Platform
All.
Workaround
Before editing a generated JWS file in Workshop open the file in a text editor and copy the line beginning:
* @editor-info:link autogen-style ...
Then, when editing the file in Workshop, restore the above line to the JWS file.
CR245418
SDO does not support periods [ . ] in element names and schema paths.
Description
SDO is dependent on XPath which supports indexing from 0. For example, SDO's Customer.0 equals XPath's Customer[1]. Since periods are already used for this type of notation, they cannot appear in element names.
A more general statement of the problem is that SDO does not support periods in schema paths, including leaf elements.
Platform
All.
Workaround
Avoid using periods in element names and schema paths.
CR265706
When no values are passed during an insert operation, the generated query contains a null, which can lead to an exception on the database side.
Description
Default values for SDO properties are always null. When no values are passed during an insert operation, the generated SQL insert contains a null. This can lead to an exception of the following form on the database side:
java.sql.SQLException: ORA-01400: cannot insert NULL into ("COMMON"."CASE"."CREATE_USERNM")
The reason this exception occurs is that when metadata is created for database tables, the default value of the database setting is not captured in SDO. So, for example, if the value of the column is "not null" in the database and the SDO datagraph passed a null value to the database, the exception will occur.
Platform
All.
Workaround
Default values should be set in the SDO client.
CR265950
End-point name changes do not take effect for operations in document style Web services.
Description
Document style Web services use input (call parameter) types to determine the Web service operation being invoked. The operation name is not included in the SOAP request. For this reason, overwriting the operation name as part of an end point change does not work for document style Web services.
Platform
All.
Workaround
None.
CR259356
Obscure error message when changing Web service end-point settings if an incorrect operation name is used.
Description
The following message:
"javax.xml.rpc.JAXRPCException: Unable to find operation 'null' in port 'AVP2Port'. Please check the WSDL"
most likely means that an invalid operation name has been selected.
Platform
All.
Workaround
Find correct operation name and change end-point settings accordingly.
CR258884
Security decisions are not audited.
Description
XQuery functions supporting security are not tracked by the audit framework.
Platform
All.
Workaround
None.
CR257878
Use of Java keywords in schema elements and namespaces may cause name conflicts.
Description
Schema elements and namespaces are converted into Java classes and packages as part of schema compilation process. This creates the potential for name conflicts with Java keywords and constructs.
Platform
All.
Workaround
Avoid as necessary using syntax which the JVM might recognize as a reserved word or construct.
CR256214
Some DBMS systems may not properly handle "pushed down" constants.
Description
SQL statements sent to base (not specifically supported) database platforms use a "best guess" as to the syntax for string literal. Such formulations may not work in all cases.
An example of this is MySQL which requires every backslash [ \ ] to be escaped with another backslash.
Such cases are not handled by SQL generation code and might result in invalid SQL being generated.
Platform
Database platforms for which only generic support is provided.
Workaround
There are two possible workarounds for this problem:
  • Convert constants to parameters by using an external variable instead of a constant. For example:
  • where $customer_id eq fn-bea:fence("CUSTOMER001")

  • Properly escape the XQuery string literal according to the rules of the underlying database.
CR253085
Invalid SQL syntax generated for MS Access when fn:lower-case() or fn:upper-case() is used.
Description
SQL generation for fn:lower-case() and fn:upper-case() functions produces SQL statements that fail to execute against MS Access database.
fn:lower-case() is translated into LOWER() and fn:upper-case( ) into UPPER( ).
The problem is that MS Access doesn't support these functions (LOWER( ) and UPPER( ) ), hence such generated SQL statements cannot be executed.
Example:
 for $i in CUSTOMER()
 where lower-case(data($i/FIRST_NAME)) eq "john"
 return $i/CUSTOMER_ID
is translated into:
 SELECT t1."CUSTOMER_ID" AS c1
 FROM "CUSTOMER" t1
 WHERE LOWER(t1."FIRST_NAME") = 'john'
Platform
All running MS-Access.
Workaround
Apply fn-bea:fence() to the parameter of an fn:lower-case() or fn:upper-case() function to block SQL pushdown and force evaluation in the engine.
Example:
 for $i in CUSTOMER()
 where lower-case(fn-bea:fence(data($i/FIRST_NAME))) eq "john"
 return $i/CUSTOMER_ID
is translated into:
 SELECT t1."CUSTOMER" AS c1, t1."FIRST_NAME"
 FROM "CUSTOMER" t1
The function can then be successfully executed by MS Access.
CR248407
Metadata import wizard fails to detect in/out parameters.
Description
In some situations associated with MSSQL and Sybase stored procedures, a resultset is returned which is not automatically detected.
Platform
All.
Workaround
First, manually build a schema that is mapped to the output of the resultset. Then, when importing metadata use the wizard, add a ROWSET and link it to the previously created schema.
CR247416
Running a Web service derived from a Data Services Control from a remote machine yields the following exception:

"Current server is the coordinator and transaction is not found."
Description
Inter-domain transactions between WebLogic Server 8.1SP4 and 8.1SP5 require that a command-line be passed.
Platform
All.
Workaround
When using inter-domain transactions between 8.1 SP4 and 8.5 SP5, the following command-line argument needs to be passed to the 8.1 SP5 domain:
 -Dweblogic.transaction.SecurityInteropMode=compatibility
More details on the JTA transaction can be found at:
CR242938
Multi-dimension soap arrays are not supported in RPC mode.
Description
The Web services wrapper provided by AquaLogic Data Services Platform only supports single-dimension arrays in RPC style Web services.
Platform
All.
Workaround
None.
CR224815
The initial invocation of a Web service from an application server typically takes more time than subsequent calls. If the timeout value is less than the time required for the first call, the alternate expression (typically a timeout error) will be evaluated.
Description
There is "startup overhead" the first time that a web service is invoked. The overhead can exceed the timeout threshold, leading to the specified timeout error.
Platform
All.
Workaround
When setting timeout on expressions that have a Web service invocation, set the timeout value to be greater than the measured amount of time required for the first invocation.
CR239369
XQueries may generate invalid SQL for databases not supporting UPPER and LOWER (SQL-92).

Also, empty input handling for base databases (databases not specifically support) as well as Oracle deviates from the XQuery specification when UPPER(null) or LOWER(null) is pushed down to the database level.
Description
There are two aspects to this problem:
  1. XQueries containing upper-case() or lower-case() functions are pushed down for database processing as UPPER and LOWER. Some databases may not support these SQL-92 keywords, however. In such cases the generated SQL will be invalid and upon execution will fail.
  2. Similarly, input handling by base databases (as well as Oracle databases) may not match the XQuery specification. The reason for this is that the XQuery specification requires that functions return an empty string if input is an empty sequence. However, when these functions are pushed down, they return an empty sequence instead. This happens because LOWER(NULL) is NULL in SQL.
Platform
All platforms running base databases and Oracle databases.
Workaround
Use the fn-bea:Fence() function to prevent pushdown of upper-case() or lower-case() functions to the database. Example:
 lower-case(fn-bea:fence(...))
CR237186
SDO update sequence is not preserved.
Description
SDO update does not preserve the sequence of update objects; instead it updates in alphabetical order (example: address, credit card, customer). Since the insertion order is automatic, the update will fail unless the update elements match alphabetical order.
Platform
All.
Workaround
If the dependency order matches alphabetical order, the update will be successful.
CR207637
An exception appears for XQuery functions accessing metadata derived from Microsoft SQL Server stored procedures containing xs:decimal.
Description
When importing a stored procedure from Microsoft SQL Server, the BEA JDBC driver incorrectly maps SQL decimal type to schema integer (xs:int) type.
Platforms
All.
Workaround
During stored procedure import, change the data type from xs:int to xs:decimal. Alternatively, you can change the imported data service's metadata to specify the schema type for the affected column to be xs:decimal.
CR203394
ROWTYPE input cursor is not supported when creating a data service from a stored procedure.
Description
Stored procedure IN and INOUT cursors containing ROWIDs are not currently supported for metadata import.
Platform
All.
Workaround
Avoid importing metadata on stored procedures which required use of IN or INOUT ROWID parameters.
CR221145
WSDLs with multiple services are not supported.
Description
A limitation of the WebLogic Web services stack affects the ability to handle WSDL files with multiple data services.
Platform
All.
Workaround
Split WSDLs with multiple data services into multiple WSDL files each with one data service.
CR214585
Erroneous results may occur when using fn:matches() with a regular expression containing a caret (^).
Description
The match beginning-of-line operator (^) in regular expressions produces erroneous results when used with fn:matches().
Platform
All.
Workaround
None available.
CR215251
Identifiers within two characters of the maximum length allowed by the DBMS may result in an error.
Description
Some DBMS systems place limits on the length of identifiers (30 in the case of Sybase). AquaLogic Data Services Platform places single quotes around queries being pushed to the database, effectively reducing the maximum identifier length by two characters (28 in the case of Sybase).
Platform
All platforms running Sybase (and possibly other) databases.
Workaround
Possible options include renaming the table or creating a view with a shorter name.
CR203174
Some data sources may not appear when importing metadata.
Description
Functionality to manage JDBC data sources and connection pools during metadata import is limited to the same level of functionality provided by BEA Workshop (Tools Arrow symbol WebLogic Server Arrow symbol DataSource Viewer).
Platform
All.
Workaround
For full functionality use the WebLogic Administration Console to manage JDBC data sources and connection pools.
CR209659
SOAP 1.2 for Web services runtime is not supported.
Description
SOAP 1.2-based Web services are not supported.
Platform
All.
Workaround
Where possible use a supported SOAP version.
CR222822
Linux applications built in Workshop may fail with the message "Error creating temporary file".
Description
While building an application inside Workshop on Linux, you may get an "Error creating temporary file" message when 1) the application includes a large number of schema files, and 2) the Platform Installation is under a different user's name than the user running Workshop.
Platform
Linux.
Workaround
Ensure that the Workshop instance is running under the same name as was used for Platform installation.
CR226019
Access control policies associated with a data service function may disappear if the function's number of parameters is changed.
Description
A data service function's signature is its QName and the number of parameters (arity) of the function. If you set security policies on a function and then change the number of parameters to the function, the function is treated as new and any previously set policies will no longer be in effect.
Platform
All.
Workaround
If a function's arity is changed, reapply security policies to that function.
CR227486
The BEA JDBC XA driver for DB2 returns the error XAER_RMERR when a local transaction read is followed by a global transaction read.
Description
Pertains to a known JDBC driver problem described in BEA CR229071.
Platform
All.
Workaround
For the 3.4 JDBC driver, set the driver property to:

AllowImplicitResultSetCloseForXA=false

CR229758
AquaLogic Data Services Platform Web service generation may fail to compile if the original Web service was created in Workshop.
Description
If you have a data service created from a Workshop-originated Web service and then, subsequently, you turn your data service into a Web service via a AquaLogic Data Services Platform control, the project build will fail due to a duplicate schema element error.
Platform
All.
Workaround
CR213916
BEA Informix JDBC driver does not return nullability information.
Description
The BEA Informix driver does not return information about table column nullability (that is, it is marked as unknown). During metadata import the minOccurs of the elements corresponding to the columns in the generated XML schemas is set to 0.
Platform
All platforms running Informix.
Workaround
Modify the imported metadata files by changing the minoccurs value for the nullable columns from 0 to 1.
CR214983, CR211701, CR201821
MSSQL VARIANT datatype has only limited support.
Description
There are two limitations with this MSSQL VARIANT data type (sql_variant):
  1. For SQL_VARIANT data type update will fail.
  2. You cannot read a null value for the SQL_VARIANT data type.
Platform
All.
Workaround
None available.
CR221015
During metadata import the BEA Sybase JDBC driver may not display all tables to which user has authorized access.
Description
During metadata import the BEA Sybase JDBC driver may not show all tables which have been granted access to the user.
Platform
All platforms accessing Sybase through the BEA Sybase JDBC driver.
Workaround
This is a BEA Sybase driver limitation. For the import purpose, you can change to dbo user to see the full complement of available tables.
CR202963
When using BEA Oracle JDBC driver with a TIMESTAMP values, stored procedures are truncated.
Description
When using the BEA's Oracle JDBC driver, if a stored procedure returns a TIMESTAMP value then the value gets truncated at the milliseconds level. For example, if the value was 1997-01-31 09:26:50.124 then the stored procedure will return a 1997-01-31 09:26:50.0 value.
Platforms
All platforms running Oracle with the BEA Oracle JDBC driver.
Workaround
Use the Oracle JDBC driver stored procedures that returning TIMESTAMP values.
CR223429, CR228802
Sybase JDBC driver does not support a getBlob() call.
Description
The AquaLogic Data Services Platform cache configuration does not work if using Sybase JDBC driver because the configuration implementation uses a getBlob( ) call on the JDBC driver. The Sybase JDBC driver does not support getBlob( ).
Platforms
All platforms running Sybase with the Sybase JDBC driver.
Workaround
Use the BEA JDBC driver for Sybase databases when utilizing Sybase as the AquaLogic Data Services Platform cache data source.
CR214730
SQL Server JDBC driver incorrectly renders the tinyint maximum value.
Description
The SQL Server tinyint maximum value of 255 gets interpreted as -1 by the Microsoft SQL Server JDBC driver.
Platforms
All platforms running SQL Server with the SQL Server JDBC driver.
Workaround
Use the BEA JDBC driver for SQL Server.
CR223486, CR226239, CR226171
The Informix JDBC driver does not support standard JDBC syntax for specifying TIMESTAMP values.
Description
The Informix native driver doesn't support standard JDBC syntax for specifying TIMESTAMP values. For example: 1979-03-01 00:00:00.0 is not supported.
Platforms
All platforms running Informix with the Informix JDBC driver.
Workaround
Use the BEA JDBC driver for Informix.
CR199675
The BEA JDBC driver for Oracle does not support UROWID column type for data retrieval.
Description
When using BEA JDBC driver for Oracle, retrieving UROWID returns an error, identified by the following message:
[BEA][Oracle JDBC Driver]Internal error: Net8 protocol error
Platforms
All platforms running Oracle with the BEA JDBC driver.
Workaround
Use the Oracle JDBC driver if your data contains UROWID column type.
CR212515
The Oracle stored procedure returning PL/SQL RECORD, BOOLEAN, or table with non-scalar element types is not supported.
Description
Oracle stored procedure limitations are detailed in the following currently-available document:
http://www.stanford.edu/dept/itss/docs/oracle/9i/java.920/a96654/ref.htm#1007714
Platforms
All platforms using Oracle.
Workaround
None available
CR202041
Metadata for SQL Server stored procedures returning CURSOR output cannot be created.
Description
When importing metadata from SQL Server, stored procedures that return CURSOR output are not supported.
Platforms
All platforms using SQL Server.
Workaround
Modify the imported data service file to identify the correct data type for the cursor.
CR227440
Metadata for DB2 stored procedures returning CLOB data cannot be created.
Description
When importing metadata from DB2, stored procedures returning CLOB data are not supported.
Platforms
All platforms using DB2.
Workaround
None available.
CR202962
Oracle stored procedures containing CHAR or NCHAR as input may cause a Server error.
Platform
All.
Description
If you have Oracle stored procedures that use an INOUT parameter, you may get an error when you run a stored procedure using AquaLogic Data Services Platform. The error appears as:
java.lang.RuntimeException: ORA-01460: unimplemented or unreasonable conversion requested
ORA-06512: at "WIRELESS.SP_CHAR", line 17
Workaround
Modify your stored procedure call by reducing the size of the INOUT parameter using TRIM. See Sample code related to CR202962, in Listing 1.

Supplemental Release Note Documentation

This section contains code and other additional information related to previously described release notes.

CR229758 Details

Summary

AquaLogic Data Services Platform Web service generation may fail to compile if the original Web service was created in Workshop.

Scenario and Workaround

Assume that you have a Workshop-generated Web service named getCustomerOrderByCustomerID. A WSDL for this Web service with default targetnamespace would create the following schema elements:

{http://www.openuri.org/}getCustomerOrderByCustomerID

and

{http://www.openuri.org/}getCustomerOrderByCustomerIDResponse

When you import this WSDL, the same schema elements will be in the imported schema file and will be associated with the data service read function. When you build a Data Service control for this read function and generate a Web service from that control, a Web service function is created:

org.openuri.GetCustomerOrderByCustomerIDResponseDocument getCustomerOrderByCustomerID(org.openuri.GetCustomerOrderByCustomerIDDocument p0)

When compiling this Web service file, WebLogic Workshop now generates two identical schema elements each:

{http://www.openuri.org/}getCustomerOrderByCustomerID

and

{http://www.openuri.org/}getCustomerOrderByCustomerIDResponse

If user had modified either the target namespace of this final JWS or changed the function name to a different one such as:

org.openuri.GetCustomerOrderByCustomerIDResponseDocument getCustomerOrderByCustomerIDNEW(org.openuri.GetCustomerOrderByCustomerIDDocument p0)

Then the types generated will be as follows:

and

Thus the schema clash would be avoided.

CR264597 Details

Summary

String comparison operations involving MSSQL may return incorrect results when the comparison operation is computed by MSSQL.

Description

Depending on the database and server configuration, MSSQL Server may use case-insensitive collation for string comparison operations (this is the default configuration).

When generating SQL the AquaLogic Data Services Platform does not take database string collation into account. This can lead to different results being produced by expressions that were "pushed down" to a MSSQL database, as compared to their evaluation by the XQuery engine.

The following types of expressions are affected:

For example, consider the following two-row, two-column table based on:

CUSTOMER(ID, FIRST_NAME)
ID
FIRST_NAME
1
John
2
john

The following XQuery might return different results depending whether it is evaluated by the database or not.

for $c in CUSTOMER()
where $c/FIRST_NAME eq "john"
return $c/ID

According to the XQuery semantics the query should return:

<ID>2</ID> 

as only the second record matches the selection criteria.

However, when AquaLogic Data Services Platform pushes the query to the underlying MSSQL database the following SQL is generated:

SELECT t1."C_ID" AS c1 
FROM "CUSTOMER" t1
WHERE t1."FIRST_NAME" = "john"

This might result in both records being returned by the MSSQL database (with case-insensitive string collation set):

<ID>1</ID>
<ID>2</ID>
Workaround

There are several workarounds to conforming with XQuery semantics for string comparisons when pushing computations down to MSSQL.

Option 1

Consider changing the collation setting that the database uses for string comparisons. See "SQL Server Collation Fundamentals" document located as of this writing at:


http://msdn.microsoft.com/library/default.asp?url=/library/en-us/architec/8_ar_da_1pwz.asp

Collation can change on a server, database or column level basis.

Option 2

Use the fn-bea:fence( ) function to block pushdown. In the above example, this would be rendered as:

for $c in CUSTOMER()
where fn-bea:fence(data($c/FIRST_NAME)) eq "john"
return $c/ID

Notice, however, that this approach may negatively impact performance since the AquaLogic Data Services Platform engine now must fetch and process the entire table.

To optimize performance, consider replicating comparison operation and pushing down one copy to be evaluated by the database while keeping the second copy on the AquaLogic Data Services Platform engine. The following query illustrates such an approach:

for $c in CUSTOMER()
where $c/FIRST_NAME eq "john"
where fn-bea:fence(data($c/FIRST_NAME)) eq "john"
return $c/ID

This query first limits the number of results that the XQuery engine must process and then applies the second selection to obtain the correct XQuery semantics.

CR202962 Listing

Listing 1 contains sample code for CR202962.

Listing 1 Sample code related to CR202962
CREATE OR REPLACE PROCEDURE WIRELESS.SP_CHAR 
(P_CHAR_IN IN CHAR,
P_CHAR_OUT OUT CHAR,
P_CHAR_INOUT IN OUT CHAR,
P_ID_OUT OUT VARCHAR2 )
IS
TEMP VARCHAR2(10);
BEGIN
SELECT C_ID INTO P_ID_OUT
FROM WIRELESS.ALL_DATATYPES
WHERE C_CHAR = P_CHAR_IN;

SELECT C_CHAR INTO P_CHAR_OUT
FROM WIRELESS.ALL_DATATYPES
WHERE C_ID = '2';

SELECT C_ID INTO TEMP
FROM WIRELESS.ALL_DATATYPES
WHERE C_CHAR = P_CHAR_INOUT;

SELECT 'WORK' INTO P_CHAR_INOUT
FROM WIRELESS.ALL_DATATYPES
WHERE C_ID = TEMP;
END;
/

to adjust the size of PCHAR_INOUT using TRIM (see highlighted code)

CREATE OR REPLACE PROCEDURE WIRELESS.SP_CHAR 
(P_CHAR_IN IN CHAR,
P_CHAR_OUT OUT CHAR,
P_CHAR_INOUT IN OUT CHAR,
P_ID_OUT OUT VARCHAR2 )
IS
TEMP VARCHAR2(10);
ACHAR CHAR(500);

BEGIN
ACHAR := trim(P_CHAR_INOUT);

SELECT C_ID INTO P_ID_OUT
FROM WIRELESS.ALL_DATATYPES
WHERE C_CHAR = P_CHAR_IN;

SELECT C_CHAR INTO P_CHAR_OUT
FROM WIRELESS.ALL_DATATYPES
WHERE C_ID = '2';

SELECT C_ID INTO TEMP
FROM WIRELESS.ALL_DATATYPES
WHERE C_CHAR = ACHAR; // used to fail here

SELECT 'WORK' INTO P_CHAR_INOUT
FROM WIRELESS.ALL_DATATYPES
WHERE C_ID = TEMP;

END;
/

CR288104 Details

Here is the Java Web service schema generated under WebLogic 9.2, following by the same schema generated under WebLogic 8.1:

First is shown the generated Web service schema under WebLogic 9.2. Notice that the schema is fully namespace qualified:

<soapenv:Envelope xmlns:soapenv="http://schemas.xmlsoap.org/soap/envelope/"; 
xmlns="http://a/b/c/d/e"; xmlns:m1="ld:DataServices/CustomerDB/CUSTOMER">
<soapenv:Body>
<hello>
<m1:CUSTOMER>
<m1:CUSTOMER_ID>s</m1:CUSTOMER_ID>
<m1:FIRST_NAME>s</m1:FIRST_NAME>
<m1:LAST_NAME>s</m1:LAST_NAME>
<m1:CUSTOMER_SINCE>2001-01-01</m1:CUSTOMER_SINCE>
<m1:EMAIL_ADDRESS>s</m1:EMAIL_ADDRESS>
<m1:TELEPHONE_NUMBER>s</m1:TELEPHONE_NUMBER>
<m1:SSN>s</m1:SSN>
<m1:BIRTH_DAY>2001-01-01</m1:BIRTH_DAY>
<m1:DEFAULT_SHIP_METHOD>s</m1:DEFAULT_SHIP_METHOD>
<m1:EMAIL_NOTIFICATION>1</m1:EMAIL_NOTIFICATION>
<m1:NEWS_LETTTER>1</m1:NEWS_LETTTER>
<m1:ONLINE_STATEMENT>1</m1:ONLINE_STATEMENT>
<m1:LOGIN_ID>s</m1:LOGIN_ID>
</m1:CUSTOMER>
</hello>

Here is the generated Web service schema under WebLogic 8.1:

<getADDRESS xmlns="http://www.openuri.org/"; 
xmlns:cus="ld:DataServices/CustomerDB/CUSTOMER">
<cus:CUSTOMER>
<CUSTOMER_ID xmlns="">string</CUSTOMER_ID>
<FIRST_NAME xmlns="">string</FIRST_NAME>
<LAST_NAME xmlns="">string</LAST_NAME>
<CUSTOMER_SINCE xmlns="">2008-09-29</CUSTOMER_SINCE>
<EMAIL_ADDRESS xmlns="">string</EMAIL_ADDRESS>
<TELEPHONE_NUMBER xmlns="">string</TELEPHONE_NUMBER>
<!--Optional:-->
<SSN xmlns="">string</SSN>
<!--Optional:-->
<BIRTH_DAY xmlns="">2014-09-19</BIRTH_DAY>
<!--Optional:-->
<DEFAULT_SHIP_METHOD xmlns="">string</DEFAULT_SHIP_METHOD>
<!--Optional:-->
<EMAIL_NOTIFICATION xmlns="">1</EMAIL_NOTIFICATION>
<!--Optional:-->
<NEWS_LETTTER xmlns="">1</NEWS_LETTTER>
<!--Optional:-->
<ONLINE_STATEMENT xmlns="">1</ONLINE_STATEMENT>
<!--Optional:-->
<LOGIN_ID xmlns="">string</LOGIN_ID>
</cus:CUSTOMER>
</getADDRESS>

 


References

The most up-to-date product documentation is available from the BEA edocs documentation Web site at the following location:


http://download.oracle.com/docs/cd/E13167_01/aldsp/docs25/index.html

To access the AquaLogic Data Services Platform documentation home page in a Web browser:

  1. Click the PDF files button.
  2. Select the document that you want to view or print.

Alternatively, from within a HTML document, click the View as PDF link on the top navigation bar to open a PDF version of the currently displayed document.

Information about BEA products including AquaLogic Data Services Platform can be found at:


http://dev2dev.bea.com

Documentation for all BEA products in both PDF and HTML format can be found at:


http://www.oracle.com/technology/documentation/index.html

If you do not have Adobe Acrobat Reader, you can obtain it from the Adobe Web site at:


http://www.adobe.com

Sample Domain

Samples, examples, sample tutorials, and the RTLApp sample application are designed to be run on the ldplatform domain, located at:

 <weblogic81>/samples/domains

The ldplatform domain contains the data necessary for these samples to be developed and run.


  Back to Top       Previous  Next