[Top] [Previous] [End of Book]

Appendix C . BEA Connect TPS Error Messages

1
<message> is too large, MAXDATALEN set too low in TPSINIT file.

2
Cannot translate FML buffer, no structure name specified in TPSINIT file.

3
Cannot find structure <type: subtype> check VIEW/FML environment variables.

4
<type: subtype> is too large, MAXDATALEN set too low in TPSINIT file.

5
Invalid field type <descriptor> in <field type>, potential BEA TUXEDO version mismatch.

6
Unsupported buffer type <type: subtype>, potential BEA TUXEDO version mismatch.

7
Received a short message header; compression or gateway version mismatch.

8
Incorrect message version, potential gateway version mismatch.

9
Invalid message length, potential gateway version mismatch.

10
Unexpected message code received, potential gateway version mismatch.

11
Remote gateway internal error <errno>, <error message>.

12
Remote target system error <errno>, <error message>.

13
Received a record of incorrect size (expected <# of bytes>, actual size.

14
Service <name> failed, logging <type: subtype> buffer.

15
Received an out-of-sequence response record, logging...

16
FML incompatible field in <viewname>.

31
Floating point underflow converting from host format.

32
Cannot convert floating point data to host format.

33
Cannot convert decimal data to host format.

34
String truncated when converted from host format.

35
Cannot convert floating point data from host format.

36
Cannot open <message catalog name> using default EBCDIC/ASCII translation.

63
Server requires FASTPATH system access.

64
Invalid command line option: <option>.

101
Service <service name> timed out by local Requester.

102
BEA Connect Requester booted.

103
Network connection <connection index> to <remote network address> dropped.

104
Cannot transform <service name> request buffer for transmission.

105
Failed to transmit <service name> request buffer.

106
Failed to receive <service name> response buffer.

107
Cannot transform <service name> response buffer as received.

108
Cannot access network device <network device>.

109
Cannot connect to network address <network address>.

110
Cannot find connect structure <type: subtype>.

111
Remote gateway information unavailable.

112
Network connection <connection index> established to <remote network addresses>.

113
Invalid service name <service name>, service not advertised in TPSINIT file.

114
BEA Connect Requester shutdown.

115
Received bad opcode version <version id>, potential BEA TUXEDO version mismatch.

116
Unsupported buffer type <type>, potential BEA TUXEDO version mismatch.

141
Invalid admin opcode <version id>, potential BEA TUXEDO version mismatch.

142
Cannot alter network signal processing.

143
Network connection <connection index> to <remote network addresses> dropped by remote gateway.

170
Invalid command <command>. Type help for available commands.

171
Cannot send remote command, invalid GWID <gateway>.

172
Failed to wakeup PID <process identification> (Check ULOG for details).

173
PID <process identification> signalled.

174
reconnectdomain (rd) command is not supported.

176
First raw message failed at tmnwsndraw().

177
Trace: State = <pgm state> Event = <current event>

178
Software Error: State = <pgm state> Event = <current event>

179
Network establishment timed out. Connection to <remote network address> closed.

180
Resending CONNECT

181
CONNECT request timed out. Connection to <remote network address> closed.

182
Network Connect interrupted, requeued.

183
ReceiveMessage: Unknown opcode = <tps operation mode>

184
ServiceRequest: Unknown event = <event number>

185
Remote host internal error <remote tperrno>, <error message>.

186
Remote host system error <remote host error #>, <error message>.

188
BEA Connect Requester shutdown for FAILOVER

211
Error recording connect/disconnect time stamp.

220
@(#)parsel.t 1.1

221
File <TPSINIT file name>, service <service name>: Invalid OUTRECTYPE type <type>.

222
File <TPSINIT file name>, service <service name>: Missing OUTRECTYPE subtype.

223
File <TPSINIT file name>, service <service name>: Unknown OUTRECTYPE <type: subtype>.

224
File <TPSINIT file name>, service <service name>: Invalid INRECTYPE type <type>.

225
File <TPSINIT file name>, service <service name>: Missing INRECTYPE subtype.

226
File <TPSINIT file name>, service <service name>: Unknown INRECTYPE type <type: subtype>.

227
Cannot process the TPSINIT file <service name>, reverting to prior settings.

228
File <TPSINIT file name>, service <service name>: Missing INBUFTYPE subtype.

229
File <TPSINIT file name>, service <service name>: Unknown INBUFTYPE type <type: subtype>.

236
File <TPSINIT file name>: Cannot open file.

241
BEA Connect Handler abnormal shutdown.

242
BEA Connect Handler normal shutdown.

243
SERVICE <remote service name>: Unknown service. Cannot map <remote service name> to local service.

244
SERVICE <service name>: Cannot send response buffer.

247
Liaison/Handler version mismatch (TPSH = <version id>, TPSL = <version id>).

248
BEA Connect Handler booted.

249
SERVICE (unknown): Cannot decode INRECTYPE from host format.

250
Cannot allocate TPINIT buffer.

251
Cannot open new connection.

252
Cannot allocate connect response buffer.

253
Cannot convert connect response buffer to host format.

254
SERVICE GATE_ADMIN: Cannot create pipe for TPSA command.

255
SERVICE <service name>: Failed to call service.

257
SERVICE <service name>: Failed to get service reply.

258
SERVICE <service name>: Cannot determine OUTBUFTYPE type.

259
SERVICE <service name>: Cannot transform OUTBUFTYPE to OUTRECTYPE.

261
Cannot propagate BEA TUXEDO environment.

263
SERVICE <service name>: Handler timed out waiting for service reply.

264
Received disconnect request from Requester.

265
Received request for unknown service - <service name>

266
Could not allocate TPINIT buffer.

267
Could not attach to BEA TUXEDO application.

268
Could not propagate BEA TUXEDO environment.

269
Connection from Requester <local network address> to Handler <remote network address> established.

270
Network establishment timed out.

271
Trace: State = <pgm state> Event = <current event>

272
Trace Event: State = <pgm state> Event = <current event>

273
Network Open <attempt number> error - ERRNO = <errno>, requeue.

274
Network Open <attempt number> error - ERRNO = <errno>, abort connection.

275
Network Accept <attempt number> error ERRNO = <errno>, requeue.

276
Network Accept <attempt number> error ERRNO = <errno>, abort accept.

277
Internal error: Unknown opcode = <tps operation code>.

278
Handler Quiescing; connection request refused.

279
Call to listen failed on fd <file descriptor> errno = <errno>

280
Connection from Requester <local network address> to Handler <remote network address> disconnected.

282
Warning: tpacall() blocked. Attempting recovery.

283
Warning: tpacall() blocked. Recovery successful.

284
tpacall() (TPEBLOCK). Recovery unsuccessful.

285
Could not get transfer fd, ioctl errno = <errno>

301
NWDEVICE = <network device>, NWADDR = <network address>

302
Cannot establish listening endpoint.

303
Cannot initialize BEA Connect Liaison.

304
Cannot enable network signal processing.

305
Cannot allocate shared memory segment (size = <number of bytes>).

306
BEA Connect Liaison booted.

307
BEA Connect Liaison shutdown.

308
BEA Connect Handler process ID: <process identifier> has terminated.

312
Maximum number of handlers in use (max handlers = <maximum # of handlers>, <MULTIPLEX parameter>).

313
Cannot accept new connection, connection refused.

317
Bad message returned from tppremsg

318
Unsupported buffer type <type>, potential BEA TUXEDO version mismatch.

319
Received bad opcode version <tps operation code>, potential BEA TUXEDO version mismatch.

339
Invalid admin opcode <tps operation code>, potential BEA TUXEDO version mismatch.

343
Maximum open files = <current maximum files> greater than MULTIPLEX = <INIT file MULTIPLEX>. MULTIPLEX reset to <new maximum file>

344
Could not create transfer pipes, errno = <errno>

345
Accept failed on listen fd <file descriptor>, errno = <errno>

346
Could not transfer fd, ioctl errno = <errno>

372
Cannot initialize FML/VIEW environment variables.

401
Data buffer compression failure.

402
Received invalid buffer length (length = <message length>, MAXDATALEN = <maximum message length>).

405
Exceeded MAX Connections for pollfds.

406
Cannot establish signaling for connection <connection file description>. <error description>

407
Too many open files. Please evaluate NUMCONNECT parameter.

408
No buffer space available. Check that network connections are available.

409
Invalid message header. Control data too short.

410
Invalid message header length.

412
Invalid message header. Cannot decode service name.

413
Invalid message; data length <message length> maxdatalen <maximum message length>

414
Network read error. Local Address <local network address> Remote Address <remote network address>: <error description>

601
GATEWAY <gateway name>: Missing GWID specification.

602
GATEWAY <gateway name>: Missing APT and/or AEQ specification.

603
GATEWAY <gateway name>: Missing TPSUT specification.

607
File <TPSINIT file name>, line <line number>: Line too long <maximum characters per line>.

608
File <TPSINIT file name>, line <line number>: No GATEWAYS specified.

609
File <TPSINIT file name>, line <line number>: Invalid/duplicate section name (expected <section name>, got <section name>).

610
File <TPSINIT file name>, line <line number>: Cannot define a gateway/service name in *GENERAL section.

611
File <TPSINIT file name>, line <line number>: Unknown <keyword> type <argument>.

612
File <TPSINIT file name>, line <line number>: Missing <keyword> subtype.

613
File <TPSINIT file name>, line <line number>: Unknown <keyword> type <type>, <subtype>.

614
File <TPSINIT file name>, line <line number>: Unknown/duplicate option <keyword>.

615
File <TPSINIT file name>, line <line number>: No SERVICES specified.

616
File <TPSINIT file name>: Cannot open file.

617
File <TPSINIT file name>: Error parsing file.

620
File <TPSINIT file name>: Duplicate GWIDs specified (GWID=<gateway name>).

621
File <TPSINIT file name>: Duplicate node/GWIPCKEY combination (<gateway name> GWIPCKEY=%d).

622
File <TPSINIT file name>: Cannot find local node/GWIPCKEY combination (<gateway name> GWIPCKEY=%d).

623
File <TPSINIT file name>: Duplicate service/GWID combination (<gateway name> GWID=<gateway IPCKEY>).

624
SERVICE <service name>: Missing GWID specification.

625
SERVICE <service name>: Unknown GWID specification (GWID=<gateway name>).

626
File <TPSINIT file name>, line <line number>: Syntax error, *GENERAL section not defined.

628
GATEWAY <gateway name>: Missing NWADDR specification.

630
MULTIPLEX=<requested MULTIPLEX>: Greater than max allowable connections per handler; Using MULTIPLEX=<actual MULTIPLEX>.

631
File <TPSINIT file name>: Warning: Duplicate NWADDR/NWDEVICE combination (<network address/network device>).

632
GATEWAY <gateway name>: FAILOVER may only be specified for a single service gateway.

1001
Cannot retrieve message <message number> from <message catalog number> catalog, using default message.

1002
Encountered system error <error message> during <function name> operation.

1003
Encountered BEA TUXEDO error (%s: %s) during <descriptor> operation.

1004
Encountered FML error (%s: %s) during <descriptor> operation.

1010
@(#)lognet.t 1000-1009 1.1

1011
Encountered TLI network error during <descriptor> operation. %s%s.

1012
Encountered socket network error during <descriptor> operation. %s%s.

1013
Encountered BEA TUXEDO network error during <descriptor> operation. %s%s.

1014
Unknown network error

1015
Network address too big

1016
Bound to wrong address

1017
Illegal global connection structure

1018
Invalid argument to network routine

1019
STARLAN lname2addr() error

1020
Local error on file transfer

1021
Error allocating space for buffers

1022
Incomplete message in buffer

1023
Illegal provider parameters

1024
Remote error on file transfer

1025
Illegal entry state for operation

1026
Error during network API call

1027
Error during UNIX system call

1028
Error in user supplied function call

1029
Error in encoding message body

1181
File <descriptor>, service <descriptor>: Invalid INRECTYPE type <type>.

1182
File <descriptor>, service <descriptor>: Missing INRECTYPE subtype.

1183
File <descriptor>, service <descriptor>: Unknown INRECTYPE type <type>:<subtype>.

1184
File <descriptor>, service <descriptor>: Invalid OUTRECTYPE type <type>.

1185
File <descriptor>, service <descriptor>: Missing OUTRECTYPE subtype.

1186
File <descriptor>, service <descriptor>: Unknown OUTRECTYPE type <type>:<subtype>.

1187
Cannot advertise service <type>.

1188
File <descriptor>, service <descriptor>: Missing OUTBUFTYPE subtype.

1189
File <descriptor>, service <descriptor>: Unknown OUTBUFTYPE type <type>:<subtype>.

1190
File <descriptor>, service <descriptor>: Invalid OUTBUFTYPE type <type>.

1191
File <descriptor>, line <descriptor>: Line too long (>nnn chrs).

1192
File <descriptor>, line <descriptor>: Duplicate service name <type>.

1193
File <descriptor>, line <descriptor>: Invalid MAXDATALEN value <value>.

1194
File <descriptor>, line <descriptor>: Invalid TIMEOUT parameter <parameter>.

1195
File <descriptor>, line <descriptor>: Unknown/duplicate option <option>.

1196
File <descriptor>: Cannot open file.

1197
Cannot process the TPSINIT file <descriptor>, reverting to prior settings.

1198
File <descriptor>, service <descriptor>: ERRORMATCH value is required.

1199
File <descriptor>, service <descriptor>: ERRORLOCATION must be specified as an offset.

1200
File <descriptor>, service <descriptor>: ERRORLOCATION field <descriptor> not found in %s:%s.

1201
File <descriptor>, service <descriptor>: Cannot convert ERRORMATCH to ERRORLOCATION field type.



[Top] [Previous] [End of Book]