[Top] [Previous] [End of Book]
Appendix C . BEA Connect TPS Error Messages
1
- <message> is too large, MAXDATALEN set too low in
TPSINIT file.
2
- Cannot translate FML buffer, no structure name specified in
TPSINIT file.
3
- Cannot find structure <type: subtype> check VIEW/FML
environment variables.
4
- <type: subtype> is too large, MAXDATALEN set too low in
TPSINIT file.
5
- Invalid field type <descriptor> in <field type>, potential BEA
TUXEDO version mismatch.
6
- Unsupported buffer type <type: subtype>, potential BEA
TUXEDO version mismatch.
7
- Received a short message header; compression or gateway
version mismatch.
8
- Incorrect message version, potential gateway version mismatch.
9
- Invalid message length, potential gateway version mismatch.
10
- Unexpected message code received, potential gateway version
mismatch.
11
- Remote gateway internal error <errno>, <error message>.
12
- Remote target system error <errno>, <error message>.
13
- Received a record of incorrect size (expected <# of bytes>, actual
size.
14
- Service <name> failed, logging <type: subtype> buffer.
15
- Received an out-of-sequence response record, logging...
16
- FML incompatible field in <viewname>.
31
- Floating point underflow converting from host format.
32
- Cannot convert floating point data to host format.
33
- Cannot convert decimal data to host format.
34
- String truncated when converted from host format.
35
- Cannot convert floating point data from host format.
36
- Cannot open <message catalog name> using default
EBCDIC/ASCII translation.
63
- Server requires FASTPATH system access.
64
- Invalid command line option: <option>.
101
- Service <service name> timed out by local Requester.
102
- BEA Connect Requester booted.
103
- Network connection <connection index> to <remote network
address> dropped.
104
- Cannot transform <service name> request buffer for
transmission.
105
- Failed to transmit <service name> request buffer.
106
- Failed to receive <service name> response buffer.
107
- Cannot transform <service name> response buffer as received.
108
- Cannot access network device <network device>.
109
- Cannot connect to network address <network address>.
110
- Cannot find connect structure <type: subtype>.
111
- Remote gateway information unavailable.
112
- Network connection <connection index> established to <remote
network addresses>.
113
- Invalid service name <service name>, service not advertised in
TPSINIT file.
114
- BEA Connect Requester shutdown.
115
- Received bad opcode version <version id>, potential BEA
TUXEDO version mismatch.
116
- Unsupported buffer type <type>, potential BEA TUXEDO
version mismatch.
141
- Invalid admin opcode <version id>, potential BEA TUXEDO
version mismatch.
142
- Cannot alter network signal processing.
143
- Network connection <connection index> to <remote network
addresses> dropped by remote gateway.
170
- Invalid command <command>. Type help for available
commands.
171
- Cannot send remote command, invalid GWID <gateway>.
172
- Failed to wakeup PID <process identification> (Check ULOG
for details).
173
- PID <process identification> signalled.
174
- reconnectdomain (rd) command is not supported.
176
- First raw message failed at tmnwsndraw().
177
- Trace: State = <pgm state> Event = <current event>
178
- Software Error: State = <pgm state> Event = <current event>
179
- Network establishment timed out. Connection to <remote
network address> closed.
180
- Resending CONNECT
181
- CONNECT request timed out. Connection to <remote network
address> closed.
182
- Network Connect interrupted, requeued.
183
- ReceiveMessage: Unknown opcode = <tps operation mode>
184
- ServiceRequest: Unknown event = <event number>
185
- Remote host internal error <remote tperrno>, <error message>.
186
- Remote host system error <remote host error #>, <error
message>.
188
- BEA Connect Requester shutdown for FAILOVER
211
- Error recording connect/disconnect time stamp.
220
- @(#)parsel.t 1.1
221
- File <TPSINIT file name>, service <service name>: Invalid
OUTRECTYPE type <type>.
222
- File <TPSINIT file name>, service <service name>: Missing
OUTRECTYPE subtype.
223
- File <TPSINIT file name>, service <service name>: Unknown
OUTRECTYPE <type: subtype>.
224
- File <TPSINIT file name>, service <service name>: Invalid
INRECTYPE type <type>.
225
- File <TPSINIT file name>, service <service name>: Missing
INRECTYPE subtype.
226
- File <TPSINIT file name>, service <service name>: Unknown
INRECTYPE type <type: subtype>.
227
- Cannot process the TPSINIT file <service name>, reverting to
prior settings.
228
- File <TPSINIT file name>, service <service name>: Missing
INBUFTYPE subtype.
229
- File <TPSINIT file name>, service <service name>: Unknown
INBUFTYPE type <type: subtype>.
236
- File <TPSINIT file name>: Cannot open file.
241
- BEA Connect Handler abnormal shutdown.
242
- BEA Connect Handler normal shutdown.
243
- SERVICE <remote service name>: Unknown service. Cannot
map <remote service name> to local service.
244
- SERVICE <service name>: Cannot send response buffer.
247
- Liaison/Handler version mismatch (TPSH = <version id>, TPSL
= <version id>).
248
- BEA Connect Handler booted.
249
- SERVICE (unknown): Cannot decode INRECTYPE from host
format.
250
- Cannot allocate TPINIT buffer.
251
- Cannot open new connection.
252
- Cannot allocate connect response buffer.
253
- Cannot convert connect response buffer to host format.
254
- SERVICE GATE_ADMIN: Cannot create pipe for TPSA
command.
255
- SERVICE <service name>: Failed to call service.
257
- SERVICE <service name>: Failed to get service reply.
258
- SERVICE <service name>: Cannot determine OUTBUFTYPE
type.
259
- SERVICE <service name>: Cannot transform OUTBUFTYPE
to OUTRECTYPE.
261
- Cannot propagate BEA TUXEDO environment.
263
- SERVICE <service name>: Handler timed out waiting for
service reply.
264
- Received disconnect request from Requester.
265
- Received request for unknown service - <service name>
266
- Could not allocate TPINIT buffer.
267
- Could not attach to BEA TUXEDO application.
268
- Could not propagate BEA TUXEDO environment.
269
- Connection from Requester <local network address> to Handler
<remote network address> established.
270
- Network establishment timed out.
271
- Trace: State = <pgm state> Event = <current event>
272
- Trace Event: State = <pgm state> Event = <current event>
273
- Network Open <attempt number> error - ERRNO = <errno>,
requeue.
274
- Network Open <attempt number> error - ERRNO = <errno>,
abort connection.
275
- Network Accept <attempt number> error ERRNO = <errno>,
requeue.
276
- Network Accept <attempt number> error ERRNO = <errno>,
abort accept.
277
- Internal error: Unknown opcode = <tps operation code>.
278
- Handler Quiescing; connection request refused.
279
- Call to listen failed on fd <file descriptor> errno = <errno>
280
- Connection from Requester <local network address> to Handler
<remote network address> disconnected.
282
- Warning: tpacall() blocked. Attempting recovery.
283
- Warning: tpacall() blocked. Recovery successful.
284
- tpacall() (TPEBLOCK). Recovery unsuccessful.
285
- Could not get transfer fd, ioctl errno = <errno>
301
- NWDEVICE = <network device>, NWADDR = <network
address>
302
- Cannot establish listening endpoint.
303
- Cannot initialize BEA Connect Liaison.
304
- Cannot enable network signal processing.
305
- Cannot allocate shared memory segment (size = <number of
bytes>).
306
- BEA Connect Liaison booted.
307
- BEA Connect Liaison shutdown.
308
- BEA Connect Handler process ID: <process identifier> has
terminated.
312
- Maximum number of handlers in use (max handlers =
<maximum # of handlers>, <MULTIPLEX parameter>).
313
- Cannot accept new connection, connection refused.
317
- Bad message returned from tppremsg
318
- Unsupported buffer type <type>, potential BEA TUXEDO
version mismatch.
319
- Received bad opcode version <tps operation code>, potential
BEA TUXEDO version mismatch.
339
- Invalid admin opcode <tps operation code>, potential BEA
TUXEDO version mismatch.
343
- Maximum open files = <current maximum files> greater than
MULTIPLEX = <INIT file MULTIPLEX>. MULTIPLEX reset
to <new maximum file>
344
- Could not create transfer pipes, errno = <errno>
345
- Accept failed on listen fd <file descriptor>, errno = <errno>
346
- Could not transfer fd, ioctl errno = <errno>
372
- Cannot initialize FML/VIEW environment variables.
401
- Data buffer compression failure.
402
- Received invalid buffer length (length = <message length>,
MAXDATALEN = <maximum message length>).
405
- Exceeded MAX Connections for pollfds.
406
- Cannot establish signaling for connection <connection file
description>. <error description>
407
- Too many open files. Please evaluate NUMCONNECT
parameter.
408
- No buffer space available. Check that network connections are
available.
409
- Invalid message header. Control data too short.
410
- Invalid message header length.
412
- Invalid message header. Cannot decode service name.
413
- Invalid message; data length <message length> maxdatalen
<maximum message length>
414
- Network read error. Local Address <local network address>
Remote Address <remote network address>: <error
description>
601
- GATEWAY <gateway name>: Missing GWID specification.
602
- GATEWAY <gateway name>: Missing APT and/or AEQ
specification.
603
- GATEWAY <gateway name>: Missing TPSUT specification.
607
- File <TPSINIT file name>, line <line number>: Line too long
<maximum characters per line>.
608
- File <TPSINIT file name>, line <line number>: No
GATEWAYS specified.
609
- File <TPSINIT file name>, line <line number>: Invalid/duplicate
section name (expected <section name>, got <section name>).
610
- File <TPSINIT file name>, line <line number>: Cannot define a
gateway/service name in *GENERAL section.
611
- File <TPSINIT file name>, line <line number>: Unknown
<keyword> type <argument>.
612
- File <TPSINIT file name>, line <line number>: Missing
<keyword> subtype.
613
- File <TPSINIT file name>, line <line number>: Unknown
<keyword> type <type>, <subtype>.
614
- File <TPSINIT file name>, line <line number>:
Unknown/duplicate option <keyword>.
615
- File <TPSINIT file name>, line <line number>: No SERVICES
specified.
616
- File <TPSINIT file name>: Cannot open file.
617
- File <TPSINIT file name>: Error parsing file.
620
- File <TPSINIT file name>: Duplicate GWIDs specified
(GWID=<gateway name>).
621
- File <TPSINIT file name>: Duplicate node/GWIPCKEY
combination (<gateway name> GWIPCKEY=%d).
622
- File <TPSINIT file name>: Cannot find local node/GWIPCKEY
combination (<gateway name> GWIPCKEY=%d).
623
- File <TPSINIT file name>: Duplicate service/GWID
combination (<gateway name> GWID=<gateway IPCKEY>).
624
- SERVICE <service name>: Missing GWID specification.
625
- SERVICE <service name>: Unknown GWID specification
(GWID=<gateway name>).
626
- File <TPSINIT file name>, line <line number>: Syntax error,
*GENERAL section not defined.
628
- GATEWAY <gateway name>: Missing NWADDR
specification.
630
- MULTIPLEX=<requested MULTIPLEX>: Greater than max
allowable connections per handler; Using
MULTIPLEX=<actual MULTIPLEX>.
631
- File <TPSINIT file name>: Warning: Duplicate
NWADDR/NWDEVICE combination (<network
address/network device>).
632
- GATEWAY <gateway name>: FAILOVER may only be
specified for a single service gateway.
1001
- Cannot retrieve message <message number> from <message
catalog number> catalog, using default message.
1002
- Encountered system error <error message> during <function
name> operation.
1003
- Encountered BEA TUXEDO error (%s: %s) during
<descriptor> operation.
1004
- Encountered FML error (%s: %s) during <descriptor>
operation.
1010
- @(#)lognet.t 1000-1009 1.1
1011
- Encountered TLI network error during <descriptor> operation.
%s%s.
1012
- Encountered socket network error during <descriptor>
operation. %s%s.
1013
- Encountered BEA TUXEDO network error during <descriptor>
operation. %s%s.
1014
- Unknown network error
1015
- Network address too big
1016
- Bound to wrong address
1017
- Illegal global connection structure
1018
- Invalid argument to network routine
1019
- STARLAN lname2addr() error
1020
- Local error on file transfer
1021
- Error allocating space for buffers
1022
- Incomplete message in buffer
1023
- Illegal provider parameters
1024
- Remote error on file transfer
1025
- Illegal entry state for operation
1026
- Error during network API call
1027
- Error during UNIX system call
1028
- Error in user supplied function call
1029
- Error in encoding message body
1181
- File <descriptor>, service <descriptor>: Invalid INRECTYPE
type <type>.
1182
- File <descriptor>, service <descriptor>: Missing INRECTYPE
subtype.
1183
- File <descriptor>, service <descriptor>: Unknown
INRECTYPE type <type>:<subtype>.
1184
- File <descriptor>, service <descriptor>: Invalid
OUTRECTYPE type <type>.
1185
- File <descriptor>, service <descriptor>: Missing
OUTRECTYPE subtype.
1186
- File <descriptor>, service <descriptor>: Unknown
OUTRECTYPE type <type>:<subtype>.
1187
- Cannot advertise service <type>.
1188
- File <descriptor>, service <descriptor>: Missing
OUTBUFTYPE subtype.
1189
- File <descriptor>, service <descriptor>: Unknown
OUTBUFTYPE type <type>:<subtype>.
1190
- File <descriptor>, service <descriptor>: Invalid
OUTBUFTYPE type <type>.
1191
- File <descriptor>, line <descriptor>: Line too long (>nnn chrs).
1192
- File <descriptor>, line <descriptor>: Duplicate service name
<type>.
1193
- File <descriptor>, line <descriptor>: Invalid MAXDATALEN
value <value>.
1194
- File <descriptor>, line <descriptor>: Invalid TIMEOUT
parameter <parameter>.
1195
- File <descriptor>, line <descriptor>: Unknown/duplicate option
<option>.
1196
- File <descriptor>: Cannot open file.
1197
- Cannot process the TPSINIT file <descriptor>, reverting to prior
settings.
1198
- File <descriptor>, service <descriptor>: ERRORMATCH value
is required.
1199
- File <descriptor>, service <descriptor>: ERRORLOCATION
must be specified as an offset.
1200
- File <descriptor>, service <descriptor>: ERRORLOCATION
field <descriptor> not found in %s:%s.
1201
- File <descriptor>, service <descriptor>: Cannot convert
ERRORMATCH to ERRORLOCATION field type.
-
-
-
[Top] [Previous] [End of Book]