Installation Guide

     Previous  Next    Open TOC in new window  Open Index in new window  View as PDF - New Window  Get Adobe Reader - New Window
Content starts here

Installing the BEA Tuxedo Mainframe Adapter for OSI TP Product

This section covers the following information:

 


Pre-Installation Considerations

Complete the following tasks prior to installing the TMA OSI TP product:

Configuring the Environment to Install TMA OSI TP

Before installing the TMA OSI TP product, you must ensure that the BEA Tuxedo system is installed and configured properly for your environment. Refer to your Tuxedo documentation for more information about setting the Tuxedo environment variables. In addition to the Tuxedo environment variables, the TMA OSI TP system requires an additional environment variable, OSIRUNDIR, before you can boot the gateway or run the osiadmin utility. Refer to the BEA Tuxedo Mainframe Adapter for OSI TP User Guide for more information about the osiadmin utility. If you do not set the OSIRUNDIR environment variable before you boot the gateway, you will receive a message telling you to set OSIRUNDIR. This environment variable specifies the path that the TMA gateway uses for runtime files. You can set the OSIRUNDIR environment variable through a script, a command line entry, or, for Windows 2003 operating systems, through the Windows System Properties in the Control Panel. The variable value should include the path and directory as appropriate for your operating system.

Upgrading from eLink OSI TP 1.3

If you are upgrading from eLink OSI TP 1.3 to BEA Tuxedo Mainframe Adapter for OSI TP 9.1, you must modify your existing dmconfig file to be compatible with the new format. The osiadmin utility performs this upgrade automatically with the importcfg command. It is recommended that you use the osiadmin utility, but you may also upgrade by manually editing your dmconfig file. Refer to the BEA Tuxedo Mainframe Adapter for OSI TP User Guide for more information about using the osiadmin utility and about manually editing the dmconfig file.

BEA Tuxedo Mainframe Adapter for OSI TP 9.1 is a full replacement for eLink OSI TP 1.3 and the Unisys Protocol Stack (OSI TP and ULS). ULS on UNIX-based systems and BEA Tuxedo Mainframe Adapter for OSI TP 9.1 both use port 102 by default. Consider this default setting when configuring the port number of your updated dmconfig file. Beginning with eLink OSI TP 4.1, you can configure a port number other than 102. This option allows you to run your eLink OSI TP 1.3 gateway while you are upgrading. If you will be using port 102 in your TMA OSI TP 9.1 dmconfig file, you must shutdown ULS before attempting to tmboot TMA OSI TP 9.1. If you are running eLink OSI TP 1.3, uninstall eLink OSI TP and the Unisys OSI TP protocol stack including the Unisys Upper Layer Services.

When you are upgrading from a previous release of the eLink OSI TP product, you must shut down all Domain administrative and gateway servers within an application domain, particularly the following:

Upgrading from eLink OSI TP 4.0

If you are upgrading from eLink OSI TP 4.0, you do not need to modify your udmconfig input file. Perform a dmloadcf of the udmconfig file to create the dmconfig binary file, BDMCONFIG. If you are running eLink OSI TP 4.0, uninstall eLink OSI TP 4.0

Note: Beginning with eLink OSI TP 4.1, the version 4.0 udmloadcf utility, the BUDMCONFIG binary file and the eLink OSI TP Administrative Server UDADM no longer exist. The function performed by the version 4.0 udmloadcf command is now done by the dmloadcf command. The information contained in the version 4.0 BUDMCONFIG file is now incorporated within the BDMCONFIG file. If your ubbconfig contains the UDMADM Server, delete it and perform a tmloadcf of the modified ubbconfig file.

 


Installing BEA TMA OSI TP on a UNIX-Based Operating System

This section explains how to install the BEA Tuxedo Mainframe Adapter for OSI TP product. For a listing of supported platforms, see Supported Platforms in the BEA Tuxedo Mainframe Adapter for OSI TP Release Notes.

To install the TMA OSI TP product, you run the install.sh script. This script installs all the necessary software components.

WARNING: For UNIX-based operating systems, if you are installing in silent mode the BEA Tuxedo system should be installed first and the TMA OSI TP product should be installed within the same directory. Use the mkdir command to create the directory where you wish to install BEA Tuxedo and the TMA OSI TP product BEFORE you perform your installations. If you do not create the directory first, you will receive an Installation Complete message after you install BEA Tuxedo, but Tuxedo will not be installed. Make sure that you have installed the Tuxedo 9.0 or 9.1 license before you install the TMA OSI TP product.

Perform the following steps to install the TMA OSI TP product on a supported UNIX platform:

  1. Log on to your UNIX platform and access the CD-ROM device.
  2. # ls -1 /dev/cdrom
    total 0
    brw-rw-rw-     1 root     sys     22,   0 January 5 10:55 c1b0t010
  3. Mount the CD-ROM with the following mount instruction if you are installing on an AIX operating system.The CD-ROM mounts automatically on Solaris.
  4. # mount -r -F cdfs /dev/cdrom/c1b0t0l0 /mnt

    Use the following mount instruction if you are installing on an HP-UX operating system:

    # mount -r -F cdfs -o cdcase /dev/cdrom/c1b0t010 /mnt 
  5. Change the directory to your CD-ROM device.
  6. # cd /mnt
  7. List the CD-ROM contents.
  8. # ls
    install.sh  hp ibm sun5x uw  windows
  9. Execute the installation script.
  10. # sh ./install.sh
  11. The installation script runs and prompts you for responses.
  12. Listing 1 Install.sh Script Prompts for an AIX Installation
    [lcsol13]:/nfs/vol1/homes1/tkumar/TMAOSITP9/unix>sh install.sh

    01) hp/hpux1123 02) ibm/aix53 03) sun5x/sol10


    Install which platform's files? [01- 3, q to quit, l for list]: 3

    ** You have chosen to install from sun5x/sol10 **

    BEA Tuxedo Mainframe Adapter OSI TP 9.1

    This directory contains BEA Tuxedo Mainframe Adapter TMA OSI TP 9.1 for
    SunOS 5.10 (Solaris) on SPARC.


    Is this correct? [y,n,q]: y

    To terminate the installation at any time
    press the interrupt key,
    typically <del>, <break>, or <ctrl+c>.

    The following packages are available:

    1 ositp BEA Tuxedo Mainframe Adapter TMA OSI TP 9.1


    Select the package(s) you wish to install (default: 1) [?,??,q]: 1

    BEA Tuxedo Mainframe Adapter TMA OSI TP 9.1
    (sparc) Release 9.1
    Copyright (c) 2006 BEA Systems, Inc.
    All Rights Reserved.
    Distributed under license by BEA Systems, Inc.
    BEA is a registered trademark of BEA Systems, Inc.


    Directory where OSI TP files are to be installed

    (Enter your Tuxedo directory path) [?,q]:
    /nfs/vol1/homes1/tkumar/tux91/sol9/tux
    edo9.1


    Using /nfs/vol1/homes1/tkumar/tux91/sol9/tuxedo9.1 as the OSI TP base
    directory
    PREREQ_SFX = T91


    Determining if sufficient space is available ...
    10544 blocks are required
    421303040 blocks are available to
    /nfs/vol1/homes1/tkumar/tux91/sol9/tuxedo9.1


    Unloading /nfs/vol1/homes1/tkumar/TMAOSITP9/unix/sun5x/sol10/ositp/OSITPT91.Z ..

    TMA/osi/samples/simpapp/dmconfig
    TMA/osi/samples/simpapp/tailor.txt
    TMA/osi/samples/simpapp/ubbsimple
    bin/GWOSITP
    bin/getulogpfx
    bin/lic.sh
    bin/osiadmin
    bin/osiltmain
    bin/portproxy
    bin/prdebuginfo
    bin/setPROXYpriv
    lib/libgwo.so
    lib/libnwunisys.so
    lib/libtasn1.so
    locale/C/LIBGWO.text
    locale/C/LIBGWO_CAT
    locale/C/libnwunisys.cat
    udataobj/gbebc2u.fld
    udataobj/jbis82u.fld
    udataobj/ksc2u.fld
    udataobj/u2gbebc.fld
    udataobj/u2jbis8.fld
    udataobj/u2ksc.fld
    10370 blocks

    ... finished

    The $TUXDIR/bin/portproxy executable listens on privileged ports (< 1024)
    on behalf of GWOSITP. The script $TUXDIR/bin/setPROXYpriv is used to
    set the appropriate permissions.



    If you know the root password, you may run setPROXYpriv now.
    Run the setPROXYpriv script? [y/n]: n
    Remember to run $TUXDIR/bin/setPROXYpriv later.


    Changing file permissions...
    ... finished


    If your license file is accessible, you may install it now.
    Install license file? [y/n]: n


    Please don't forget to use lic.sh located in your product bin directory
    to install the license file from the enclosed floppy.
    Refer to your product Release Notes for details on how to do this.


    Installation of BEA Tuxedo Mainframe Adapter TMA OSI TP 9.1 was successful.


    Please don't forget to fill out and send in your registration card
Note: The following message may also appear during installation on HP machines:
Listing 2 Warning Message
===================================================
You do NOT HAVE required HP Patches for Tuxedo 9.1
Please refer to the Tuxedo 9.1 Installation Guide
or http://download.oracle.com/docs/cd/E13203_01/tuxedo/tux90/install/inspds.htm#1318335
for more information.

Continue Installation? [y/n]:
Note: If you receive this warning, enter n to exit installation and refer to your Tuxedo 9.1 Installation Guide for more information.

Distribution Libraries and Executables for AIX

The TMA OSI TP CD-ROM contains the following libraries and executable programs for the AIX 5.3 operating system:

Table 1 TMA OSI TP Distribution Libraries for AIX 5.3
Directory
Files
/bin
getulogpfx
GWOSITP
osiadmin
osiltmain
portproxy
prdebuginfo
setPROXYpriv
/lib
libgwo.so
libnwunisys.so
libtasn1.so
/locale/C
LIBGWO.text
LIBGWO_CAT
libnwunisys.cat
/udataobj
gbebc2u.fld
jbis82u.fld
ksc2u.fld
u2gbebc.fld
u2jbis8.fld
u2ksc.fld
$TUXDIR/tma/osi/
samples/simpapp
dmconfig
ubbsimple
tailor.txt

Distribution Libraries and Executables for HP-UX

The TMA OSI TP CD-ROM contains the following libraries and executable programs for the HP-UX 11.23 operating system:

Table 2 TMA OSI TP Distribution Libraries for HP-UX 11.23
Directory
Files
/bin
getulogpfx
GWOSITP
osiadmin
osiltmain
portproxy
prdebuginfo
setPROXYpriv
/lib
libgwo.sl
libnwunisys.sl
libtasn1.sl
/locale/C
LIBGWO.text
LIBGWO_CAT
libnwunisys.cat
/udataobj
gbebc2u.fld
jbis82u.fld
ksc2u.fld
u2gbebc.fld
u2jbis8.fld
u2ksc.fld
$TUXDIR/tma/osi/
samples/simpapp
dmconfig
ubbsimple
tailor.txt

Distribution Libraries and Executables for Solaris

The TMA OSI TP CD-ROM contains the following libraries and executable programs for the Solaris operating system:

Table 3 TMA OSI TP Distribution Libraries for Solaris
Directory
Files
/bin
getulogpfx
GWOSITP
osiadmin
osiltmain
portproxy
prdebuginfo
setPROXYpriv
/lib
libgwo.so
libnwunisys.so
libtasn1.so
/locale/C
LIBGWO.text
LIBGWO_CAT
libnwunisys.cat
/udataobj
gbebc2u.fld
jbis82u.fld
ksc2u.fld
u2gbebc.fld
u2jbis8.fld
u2ksc.fld
$TUXDIR/tma/osi/
samples/simpapp
dmconfig
ubbsimple
tailor.txt

 


Installing BEA Tuxedo Mainframe Adapter for OSI TP on Windows 2003 Advanced Server

Caution: Be sure to review the Pre-Installation Considerations section before you start your installation of the BEA Tuxedo Mainframe Adapter for OSI TP Version 9.1 product.

Perform the following steps to install the TMA OSI TP product on a Windows 2003 operating system:

WARNING: For Windows 2003 operating systems, the BEA Tuxedo system should be installed first and the TMA OSI TP product should be installed within the same directory.
  1. Insert the TMA OSI TP product CD-ROM in your CD-ROM drive. The Installation program should automatically start. If it does not start automatically, perform the following steps to begin the installation:
    1. Click the Start button, and select the Run option. The Run window displays.
    2. Click the Browse button to select the CD-ROM drive.
    3. Select the windows directory and select the Setup.exe program.
    4. Click OK to run the executable and begin the installation. Setup searches to make sure the Tuxedo product is installed on your system.
    5. Note: If the Tuxedo product is NOT already installed on your system, an Error pop-up window displays. Click OK on the pop-up window to terminate the installation process. Install the Tuxedo product on your system and re-instate the installation process.
  2. Setup also notifies you if a prior version of the TMA OSI TP product is installed. If a prior version is detected, you are asked if you want to continue with Setup. Click Yes and the Welcome window displays as shown in Figure 1.
  3. Figure 1 Welcome Window


    Welcome Window

  4. Click Next to continue with the installation. The License Agreement window displays as shown in Figure 2.
  5. Figure 2 License Agreement Window


    License Agreement Window

  6. Read the license agreement information, and click Yes to continue with the installation.
  7. The User Information window displays as shown in Figure 3. Enter your name in the Name field. Enter the name of your company in the Company field. Click Next to continue with the installation.
  8. Figure 3 User Information Window


    User Information Window

  9. The install license file Question pop-up window displays as shown in Figure 4. Click Yes to install your License File now.
  10. Note: If you click Yes, the BEA Tuxedo Mainframe Adapter for OSI TP license file is appended to the existing Tuxedo license file, $TUXDIR\udataobj\lic.txt. If you click No, you will need to manually add the TMA OSI TP license to the end of the lic.txt file.
    Figure 4 Install License File Question


    Install License File Question

  11. When you click Yes to install the License File, the Select License File Source Directory window displays as shown in Figure 5.
    1. Enter the Directory and Path or click the Browse button to display the Choose Folder pop-up window.
    2. Figure 5 Select License File Source Directory Window


      Select License File Source Directory Window

    3. If you clicked Browse, locate the License file and click OK to return to the Select License File Source Directory window. Then click Next to continue with the installation process.
  12. The installation begins and a progress bar displays the status. The TMA OSI TP components install into the Tuxedo directory. You may abort the installation process anytime prior to completion by clicking Cancel.
  13. Note: During the TMA OSI TP installation, the $TUXDIR\udataobj\DMTYPE file is updated to include an OSITPX entry if one is not already there.
  14. The Setup Complete window, as shown in Figure 6 notifies you that the TMA OSI TP product is installed on your system. Click Finish to complete the setup process.
  15. Figure 6 Setup Complete


    Setup Complete

Distribution Libraries and Executables for Windows 2003 Advanced Server

The TMA OSI TP CD-ROM contains the following libraries and executable programs for Windows 2003 operating systems. After installing the TMA OSI TP product, verify that these files and programs are installed on your system.

Table 1 TMA OSI TP Distribution Libraries for Windows 2003 Advanced Server
Directory
Files
/bin
DbgHelp.dll
gwo.dll
GWOSITP.exe
nwunisys.dll
osiadmin.exe
osilt.dll
osiltmain.exe
osiltpp.dll
osiltppmain.exe
osimsg.dll
Psapi.dll
tasn1.dll
/locale/C
LIBGWO.text
LIBGWO_CAT
/udataobj
gbebc2u.fld
jbis82u.fld
ksc2u.fld
u2gbebc.fld
u2jbis8.fld
u2ksc.fld
$TUXDIR/tma/osi/
samples/simpapp
dmconfig
ubbsimple
tailor.txt

Uninstalling BEA Tuxedo Mainframe Adapter for OSI TP Product on Windows 2003 Advanced Server

Perform the following steps to uninstall TMA OSI TP on a Windows 2003 system:

Note: Make sure that TMA OSI TP is shut down before you uninstall.
  1. Click the Start button, and then point to Settings. Point to the folder that contains Control Panel, and then click Control Panel.
  2. Double click on the Add/Remove Programs option from the Control Panel listings to access the Add/Remove Programs properties window.
  3. In the Add/Remove Programs Properties window, select BEA Tuxedo Mainframe Adapter for OSI TP from the program list and click the Add/Remove button.
  4. The uninstall process for TMA OSI TP begins. The Remove Programs From Your Computer screen displays. Click OK to complete the uninstall process.
  5. Figure 7 Remove Programs From Your Computer Screen


    Remove Programs From Your Computer Screen


  Back to Top       Previous  Next