The following section describes known issues in WebLogic Network Gatekeeper 1.0.


Known Issues

Change Request Number

Description

iCR1222

Some system configuration values are not distributed between SLEE instances. Workaround: Configure the value on each SLEE instance.

iCR1204

Statistics may be lost when shutting down the system since the data is written do the Database once every fifth minute, and no forced write is done during shutdown. Workaround: After all traffic has stopped, wait 5 minutes before performing the shut down.

iCR1093

Account added directly to the system using Access will not be accessible through PMT. Workaround: Choose one way of creating accounts and stick to that one. Either through PMT or directly using Access.

 