1000 |
ERROR: config file <%s> not found |
|
Description
|
The
BEA TUXEDO/BEA TOP END gateway configuration file was not found. (This file is specified
with the -f parameter-on
the CLOPT line for the
gateway-in the SERVERS
section of ubbconfig .) |
Action
|
Create
a configuration file (if one does not exist) and set the -f (CLOPT ) parameter. |
1001 |
WARN: unknown section <%s> in %s - skipping |
|
Description
|
Valid
sections for the gateway configuration file are:
|
Action
|
The
system ignores the line containing the name of the invalid section. If this behavior is
acceptable, then no action is required. (Even if it is acceptable for this line to be
ignored, however, it is a good idea to delete it to maintain a clean file.) If the name is invalid because of a spelling or typing error, then
correct the error. |
1002 |
ERROR: service name <%s> too long, max %d characters
|
|
Description
|
The
service name specified in the service definition file (as specified by the -f CLOPT parameter) contains more than
the maximum number of characters supported by the BEA TUXEDO system. The gateway will exit
gracefully. |
Action
|
Modify
the service names in the configuration file and re-boot the gateway. |
1003 |
ERROR: syntax error in configuration file: <%s>
|
|
Description
|
A
syntax error was detected in the service definition file specified by the -f CLOPT parameter. The gateway will
exit gracefully. |
Action
|
Fix
the indicated line and re-boot the gateway. |
1004 |
ERROR: product name <%s> too long, max %d characters
|
|
Description
|
The
product name specified in the service definition file (as specified by the -f CLOPT parameter) contains more than
the maximum number of characters supported by BEA TOP END. The gateway will exit
gracefully. |
Action
|
Modify
the product names in the configuration file and re-boot the gateway. |
1005 |
ERROR: function name <%s> too long, max %d characters
|
|
Description
|
The
function name specified in the service definition file (as specified by the -f CLOPT parameter) contains more than
the maximum number of characters supported by BEA TOP END. The gateway will exit
gracefully. |
Action
|
Modify
the function names in the configuration file and re-boot the gateway. |
1006 |
ERROR: target name <%s> too long, max %d characters
|
|
Description
|
The
target name specified in the service definition file (as specified by the -f CLOPT parameter) contains more than
the maximum number of characters supported by BEA TOP END. The gateway will exit
gracefully. |
Action
|
Modify
the target names in the configuration file and re-boot the gateway. |
1007 |
ERROR: unknown tag <%s> in %s |
|
Description
|
An
unknown tag was found in the service definition file specified by the -f CLOPT parameter. The gateway will
exit gracefully. |
Action
|
Correct
the configuration file and re-boot the gateway. |
1008 |
ERROR: exceeded number of entries (%d) supported by gateway
|
|
Description
|
The
service definition file (specified by the -f CLOPT
parameter) contains more entries than can be supported by the gateway. The gateway will
exit gracefully. |
Action
|
Either
remove service entries from the configuration file, or configure a second gateway (with a
second configuration file) and segment the services. |
1009 |
ERROR: service <%s> does not have PRODUCT defined in
file %s |
|
Description
|
PRODUCT is a mandatory field. It
must be specified, either on the DEFAULT :
line or in each service entry. |
Action
|
Add
product names as appropriate and re-boot the gateway. |
1010 |
ERROR: multiple product names not allowed in
TE_LOCAL_SERVICES section |
|
Description
|
The
GWTE2TUX gateway
supports a single product name. All service entries in the TE_LOCAL_SERVICES section must have
the same product name. |
Action
|
Modify
the file so that all product names in the LOCAL_SERVICES section are the same. If multiple products are
needed, use an additional configuration file to configure a second gateway with a
different product name. |
1011 |
WARN: Unable to establish connection to TOP END |
|
Description
|
The
gateway was unable to connect to the BEA TOP END system. The gateway needs to connect to a
BEA TOP END Network Agent. |
Action
|
Make
sure that the BEA TOP END Network Agent (NA) is running and configured properly. Also make
sure that the BEA TOP END remote configuration file (as specified by the -c CLOPT parameter, or topendrc.cfg by default) is
configured with the proper BEA TOP END system, machine, and port number. |
1012 |
ERROR: Cannot allocate TOP END client DIF structure |
|
Description
|
The
gateway was unable to allocate the memory needed for BEA TOP END communication. The
gateway will retry the allocation as specified by the -R CLOPT parameter. |
Action
|
Make
sure the operating system parameters are set correctly for the amount of memory on the
machine and the amount of memory that can be used by a process. Reduce the memory usage on
the machine or increase the amount of physical memory on the machine. |
1013 |
ERROR: Sign on to TOP END failed. Error code=%s(%d). server
exiting... |
|
Description
|
The
GWTUX2TE gateway issued
a call to tp_client_signon
(to sign on to the BEA TOP END system) and the call failed. |
Action
|
Check
the description of the error code available in the tp_client_signon (3T) entry in the BEA
TOP END Reference Manual. |
1014 |
ERROR: username and password (-u and -p) invalid or not
specified |
|
Description
|
The
GWTUX2TE gateway has
invalid credentials and has failed BEA TOP END authentication. |
Action
|
Modify
the user name or password (using the -u
or -p parameter,
respectively), or add the user_ID/password combination to the BEA TOP END security
database. |
1015 |
ERROR: failed on TOP END receive during initialization. Error
code=%s(%d) |
|
Description
|
The
GWTUX2TE gateway failed
to receive a response from BEA TOP END for the call to tp_client_signon . |
Action
|
Check
the description of the error code available in the tp_client_receive (3T) entry in the BEA
TOP END Reference Manual. |
1016 |
ERROR: failed on TOP END send. retcode=%s(%d) extended
status=%s(%d) |
|
Description
|
The
GWTUX2TE gateway was
unable to send the message to the BEA TOP END system. |
Action
|
Check
the description of the error code available in the tp_client_send (3T) entry in the BEA
TOP END Reference Manual. |
1017 |
ERROR: failed on TOP END receive. retcode=%s(%d) extended
status=%s |
|
Description
|
The
GWTUX2TE gateway was
unable to receive a response from the BEA TOP END system. |
Action
|
Check
the description of the error code available in the tp_client_receive (3T) entry in the BEA
TOP END Reference Manual. |
1018 |
WARN: TOP END server sent response with TP_APPL_CONTEXT.
Resetting dialog |
|
Description
|
The
BEA TOP END server set the TP_APPL_CONTEXT
flag with the response. This flag is not supported by the gateway. The gateway sent an
error back to the server and reset the dialog. The gateway can continue processing. |
Action
|
The
TP_APPL_CONTEXT flag is
not supported by the gateway. The application should be modified so that the flag is not
set. |
1019 |
INFO: stale response message received from TOP END - ignoring
|
|
Description
|
The
response that was received is apparently an orphaned response. This problem can occur when
the gateway goes down and restarts. The gateway continues to search for the matching
response. |
Action
|
No
action is required. |
1020 |
ERROR: TOP END initialization Failed. error code=%s(%d)
|
|
Description
|
The
GWTUX2TE gateway failed
on the call to tp_initialize .
|
Action
|
Check
the description of the error code available in the tp_initialize (3T) entry in the BEA
TOP END Reference Manual. |
1021 |
ERROR: service definition file (-f )not specified. Exiting
server... |
|
Description
|
The
-f parameter is required
in the list of CLOPT
options for the gateway. |
Action
|
Add
the -f parameter to the
list of CLOPT options
for the gateway and re-boot the BEA TUXEDO system. |
1022 |
ERROR: cannot access MIB for security info. %s. Exiting
server... |
|
Description
|
The
-u and -g parameters were specified for the
gateway. The gateway needs to perform a MIB look-up to obtain the appropriate security
credentials. The MIB request failed. |
Action
|
Verify
that the TMIB service is
advertised. |
1023 |
ERROR: cannot access MIB for security info. %s. Exiting
server... |
|
Description
|
The
-u and -g parameters were specified for the
gateway. The gateway needs to perform a MIB look-up to obtain the appropriate security
credentials. The MIB request failed. |
Action
|
Verify
that the TMIB service is
advertised. |
1024 |
ERROR: unable to allocate TOP END receive buffer. Exiting
server... |
|
Description
|
The
gateway was unable to allocate the memory needed for BEA TOP END communication. |
Action
|
Make
sure the operating system parameters are set correctly for the amount of memory on the
machine and the amount of memory that can be used by a process. Reduce the memory usage on
the machine or increase the amount of physical memory on the machine. |
1026 |
ERROR: TOP END tp_csi_alloc Failed. Exiting server...
|
|
Description
|
The
gateway was unable to allocate the memory needed for BEA TOP END communication. |
Action
|
Make
sure the operating system parameters are set correctly for the amount of memory on the
machine and the amount of memory that can be used by a process. Reduce the memory usage on
the machine or increase the amount of physical memory on the machine. |
1027 |
ERROR: function %8.8s not found |
|
Description
|
The
GWTE2TUX gateway
received a BEA TOP END client request with a function name that is not recognized by the
gateway. The gateway sent an error to the client. It will continue processing. |
Action
|
Check
the service definition file to verify the function names. |
1028 |
ERROR: failed to convert message to BEA TUXEDO format
|
|
Description
|
The
gateway was unable to convert the BEA TOP END client request into the BEA TUXEDO buffer
format. |
Action
|
Check
the message in the userlog preceding this message for further information. Possible
symptoms are: message too large (max 30K), unsupported BEA TUXEDO buffer type. |
1029 |
ERROR: failure attempting to reach service %s (%s) |
|
Description
|
The
GWTE2TUX gateway was
unable to reach the specified BEA TUXEDO service. The specific error is indicated in
parentheses. |
Action
|
Probable
causes are: the service is not advertised or is suspended, or the service name advertised
by the BEA TUXEDO system (as specified in the SERVICES section of ubbconfig ) does not match the service name in the gateway's
service definition file. Make sure the service is advertised and the service names in ubbconfig and the service definition
file match. Also check the error value in tpacall (3c). |
1030 |
ERROR: failure attempting to get reply from service %s (%s) |
|
Description
|
The
GWTE2TUX gateway was
unable to receive a response from the BEA TUXEDO service. The specific error is indicated
in parentheses. |
Action
|
Check
the error value in tpgetrply (3c).
|
1031 |
ERROR: failed to convert message to TOP END format |
|
Description
|
The
gateway was unable to convert the BEA TUXEDO server response into the BEA TOP END buffer
format. |
Action
|
Check
the message in the userlog preceding this message for further information. Possible
symptoms are: message too large (max 30K), unsupported BEA TUXEDO buffer type. |
1032 |
ERROR: tp_server_send failed with unknown TOP END receive
code [%d] |
|
Description
|
The
gateway received an unknown receive code from the tp_server_send () call. The gateway
will continue to process messages. |
Action
|
No
action is required. |
1033 |
ERROR: tp_server_send failed with unknown TOP END receive
code [%d] |
|
Description
|
The
gateway received an unknown receive code from the tp_server_send () call. The gateway
will continue to process messages. |
Action
|
No
action is required. |
1034 |
ERROR: Conversational services not supported by gateway
|
|
Description
|
The
gateway does not support conversation services (tpconnect , tpsend ,
and tprecv ). |
Action
|
BEA
TUXEDO clients and servers should be built to use the request/response paradigm. |
1035 |
ERROR: Transactions not supported by gateway |
|
Description
|
The
gateway does not support transactions (tpbegin
and tpcommit ). |
Action
|
The
client call to the BEA TOP END service should include the TPNOTRAN flag. |
1037 |
ERROR: Tuxedo->TopEnd service mapping not found for
service %s |
|
Description
|
The
name of the BEA TUXEDO service specified in the error message is not included in the table
for the GWTUX2TE
gateway. |
Action
|
Check
the service definition file for the gateway to see if it includes an entry for the service
name. |
1038 |
ERROR: invalid value specified for wait time (-w), Server
exiting... |
|
Description |
The
wait time must be greater than or equal to 0. |
Action |
Modify
the wait time to a valid value. |
1039 |
ERROR: can't open password file <%s>, fopen errno=%d.
Server exiting |
|
Description
|
The
password file (specified by the -p
CLOPT parameter) cannot
be accessed. Possible causes are: the file does not exist, or the permissions are not
valid. |
Action
|
Ensure
that the file exists and is readable by the BEA TUXEDO administrator. |
1040 |
ERROR: service definition file (-f )not specified. Server
exiting... |
|
Description
|
The
-f parameter is required
in the list of CLOPT
options for the gateway. |
Action
|
Add
the -f parameter to the
list of CLOPT options
for the gateway and re-boot the BEA TUXEDO system. |
1041 |
ERROR: service definition file (-f )not specified. Server
exiting... |
|
Description
|
The
-f parameter is required
in the list of CLOPT
parameters for the gateway. |
Action
|
Add
the -f parameter to the
list of CLOPT options
for the gateway and re-boot the BEA TUXEDO system. |
1042 |
ERROR: unable to allocate TOP END receive buffer |
|
Description
|
The
gateway was unable to allocate the memory needed for BEA TOP END communication. |
Action
|
Make
sure the operating system parameters are set correctly for the amount of memory on the
machine and the amount of memory that can be used by a process. Reduce the memory usage on
the machine or increase the amount of physical memory on the machine. |
1043 |
INFO: retrying connection to TOP END every %d seconds
|
|
Description
|
The
gateway was unable to connect to BEA TOP END; it will perform periodic retries. The
gateway will not advertise remote services until a connection is established. |
Action
|
No
action is required. |
1044 |
INFO: connection established to TOP END |
|
Description
|
The
gateway has successfully connected to BEA TOP END. |
Action
|
No
action is required. |
1045 |
WARN: Network connection closed by TOP END |
|
Description
|
The
network connection has been closed for one of the following reasons: the BEA TOP END
system was shut down, the NA was shut down, or the network connection was broken. |
Action
|
If
you have planned this downtime, no action is required. If you have not planned this
downtime, check the BEA TOP END system and bring it up if necessary. Also check network
connectivity. |
1046 |
WARN: Network connection closed by TOP END |
|
Description
|
The
network connection has been closed for one of the following reasons: the BEA TOP END
system was shut down, the NA was shut down, or the network connection was broken. |
Action
|
If
you have planned this downtime, no action is required. If you have not planned this
downtime, check the BEA TOP END system and bring it up if necessary. Also check network
connectivity. |
1047 |
WARN: Network connection closed by TOP END |
|
Description
|
The
network connection has been closed for one of the following reasons: the BEA TOP END
system was shut down, the NA was shut down, or the network connection was broken. |
Action
|
If
you have planned this downtime, no action is required. If you have not planned this
downtime, check the BEA TOP END system and bring it up if necessary. Also check network
connectivity. |
1048 |
WARN: Network connection closed by TOP END |
|
Description
|
The
network connection has been closed for one of the following reasons: the BEA TOP END
system was shut down, the NA was shut down, or the network connection was broken. |
Action
|
If
you have planned this downtime, no action is required. If you have not planned this
downtime, check the BEA TOP END system and bring it up if necessary. Also check network
connectivity. |
1049 |
ERROR: function <%s: default from service> too long,
max %d chars |
|
Description
|
The
BEA TOP END function name defaults to the BEA TUXEDO service name. The number of
characters in the BEA TUXEDO service name does not exceed the number allowed for service
names, but it does exceed the number of characters allowed for function names. |
Action
|
Add
a function name that contains no more than eight characters to the service definition file
and re-boot the gateway. |
1050 |
WARN: unable to connect to TOP END system and retry option is
disabled. Exiting server..." |
|
Description
|
The
-R parameter was
specified as 0 in the CLOPT entry for the gateway. The
gateway may restart and attempt to connect again (if it has been configured for restart). |
Action
|
No
action is required. |
1051 |
WARN: unsupported command-line option %c |
|
Description
|
The
option specified in the CLOPT
line for the gateway is not recognized. The gateway ignores it. |
Action
|
No
action is required. |
1052 |
ERROR: call to tgAllocTuxedoBuffer failed |
|
Description
|
The
gateway was unable to allocate the memory needed for BEA TUXEDO communication. |
Action
|
Make
sure the operating system parameters are set correctly for the amount of memory on the
machine and the amount of memory that can be used by a process. Reduce the memory usage on
the machine or increase the amount of physical memory on the machine. |
1053 |
ERROR: call to tgConvertMessage failed TUX2TE incoming
|
|
Description
|
The
gateway was unable to convert the BEA TUXEDO client request into the BEA TOP END buffer
format. |
Action
|
Check
the message in the userlog preceding this message for further information. Possible
symptoms are: message too large (max 30K), unsupported BEA TUXEDO buffer type. |
1054 |
ERROR: call to tgConvertMessage failed TUX2TE outgoing
|
|
Description
|
The
gateway was unable to convert the BEA TOP END server response into the BEA TUXEDO buffer
format. |
Action
|
Check
the message in the userlog preceding this message for further information. Possible
symptoms are: message too large (max 30K), unsupported BEA TUXEDO buffer type. |
1055 |
ERROR: no service mappings defined in file %s |
|
Description
|
No
entries for the gateway are included in the service definition file. For the GWTE2TUX gateway, there are no
entries in the TE_LOCAL_SERVICES
section. For the GWTUX2TE
gateway, there are no entries in the TE_REMOTE_SERVICES
section. |
Action
|
Add
service entries for the gateway. |
1056 |
INFO: TOP END admin message: %s |
|
Description
|
A
BEA TOP END administrative message was sent to the gateway. |
Action
|
No
action is required. |
1057 |
WARN: error while processing TOP END admin message [%d, %s]
|
|
Description
|
A
BEA TOP END administrative message was sent to the gateway and an error occurred in the tp_system_admin () call. |
Action
|
No
action is required. |
1058 |
WARN: error while processing TOP END admin message [%d]
|
|
Description
|
A
BEA TOP END administrative message was sent to the gateway and an error occurred in the tp_system_admin () call. |
Action
|
No
action is required. |
1058 |
ERROR: tp_server_send failed [%d,%s], ext_status=[%d,%s]
|
|
Description
|
The
GWTE2TUX gateway failed
an attempt to send the response to the BEA TOP END client. The gateway will continue to
process messages. |
Action
|
Check
the description of the error code available in the tp_server_send (3T) entry in the BEA
TOP END Reference Manual. |