Siebel Data Quality Administration Guide > Enabling and Disabling Data Matching and Data Cleansing > Enabling Data Quality at the Object Manager Level >

Enabling Data Quality Using the GUI


To enable data quality at the object manager level using the GUI, complete the steps in the following procedure.

To enable data quality at the object manager level using the GUI

  1. Log in to the Siebel application with administrator responsibilities.
  2. Navigate to the Administration - Server Configuration screen, then the Servers view.
  3. In the Components list, select an object manager where end users enter and modify customer data.

    For example, select the Call Center Object Manager (ENU) if you want to enable or disable real-time data matching or cleansing for that object manager.

  4. Click the Parameters subview tab.
  5. In the Parameters field in the Component Parameters list, apply the appropriate settings to the parameters listed in the following table to enable or disable data matching or cleansing.
    Field
    Description

    Data Cleansing Enable Flag

    Indicates whether real-time data cleansing is enabled for a specific object manager, such as Call Center Object Manager (ENU). This parameter allows you to set different data cleansing values in different object managers. By default, all values for this parameter are set to False.

    DeDuplication Enable Flag

    Indicates whether real-time data matching is enabled for a specific object manager, such as Call Center Object Manager (ENU). This parameter allows you to set different data matching values in different object managers. By default, all values for this parameter are set to False.

    Data Cleansing Type

    Indicates the third-party vendor software that is used for data cleansing.

    DeDuplication Data Type

    Indicates the third-party vendor software that is used for data matching.

    NOTE:  The settings at this object manager level override the enterprise-level settings.

  6. After the component parameters are set, restart the object manager either by using srvrmgr or by completing the following sub-steps:
    1. Navigate to the Administration - Server Management screen, then the Servers view.
    2. Click the Components Groups view tab (if not already active).
    3. In the Servers list (upper applet), select the appropriate Siebel Server (if you have more than one in your enterprise).
    4. In the Components Groups list (middle applet), select the component of your object manager, and use the Startup and Shutdown buttons to restart the component.

      For information about restarting server components, see Siebel System Administration Guide.

Siebel Data Quality Administration Guide Copyright © 2013, Oracle and/or its affiliates. All rights reserved. Legal Notices.