Siebel System Monitoring and Diagnostics Guide > Querying System Log Files >

Troubleshooting Log File Analyzer Errors


This topic provides guidelines for resolving errors and problems that the Log File Analyzer (LFA) might generate during processing. To resolve the problem, look for it in the Symptom/Error Code and Message column in Table 37.

Table 37. Resolving Log File Analyzer Problems
System or Error Code and Message
Diagnostic Steps or Cause
Solution

SBL-LFA-00100

Section [%s] in configuration file is empty.

The section indicated in the error message is blank. LFA requires content for this section.

For the correct specification of the configuration file, see Configuring the Log File Analyzer.

SBL-LFA-00101

Rule "%s" appears in the configuration file but is not registered.

A rule has been added to the LFA configuration file but not registered with the utility. Therefore, the rule is not recognized.

At this time, it is not possible to create customized rules for the LFA. Remove this rule from the configuration file.

SBL-LFA-00102

Cannot find section [%s] in the configuration file.

Though it is a required section, the section of the LFA configuration file indicated in the error message text is missing.

For the correct specification of the configuration file, see Configuring the Log File Analyzer.

SBL-LFA-00103

There is a format problem in section [%s] of the configuration file.

There is a formatting error in the LFA configuration file section indicated in the error message text.

For the correct specification of the configuration file, see Configuring the Log File Analyzer.

SBL-LFA-00104

Value "%s" in the section is invalid or missing.

There is a missing value in the LFA configuration file section indicated in the error message text.

For the correct specification of the configuration file, see Configuring the Log File Analyzer.

SBL-LFA-00105

Time filters are invalid or have contradictory values.

The time filter you are trying to use in your query is invalid. It is possible that the To time is before the From time.

For information on using time filters correctly, see Querying Log Files Within a Time Interval.

SBL-LFA-00106

Value or Name for "%s" is a negative number.

This value is not expected to be negative.

Provide a positive value.

SBL-LFA-00107

Cannot open file: "%s".

The LFA cannot write output to the given file.

Check your permissions to the file and directory. Make sure the file is not read only.

SBL-LFA-00108

File "%s" is already in use.

This file might be locked by another running application.

Shut down applications that might be accessing the file and try again.

SBL-LFA-00109

Cannot create pipe for command \"%s\".

Pipe is not supported.

This functionality is not supported.

SBL-LFA-00110

OUT OF MEMORY !!!!!!

The computer on which you are using the LFA has run out of memory.

Shut down some of your applications and try again.

SBL-LFA-00112

Query's "where" clause is invalid.

The where clause in the query is not correctly specified.

For information on correct application of the WHERE clause, see Creating and Saving LFA Queries.

SBL-LFA-00113

Query with name "%s" does not exist.

You have tried to reference a query that does not exist.

Type list queries to see existing queries. If your query does not exist, you must create it before trying to reference it. For information on creating queries, see Creating and Saving LFA Queries.

SBL-LFA-00114

Filter for "%s" does not exist.

The specified parameter cannot be used as a filter.

Do not use this item as a query parameter.

SBL-LFA-00115

Category "%s" does not exist.

You tried to use the specified word, but only key words are expected

Fix the command and try again. For information on key words, see Listing Query Command Key Words.

SBL-LFA-00116

Object "%s" does not exist.

The object (that is, Siebel Server, plug-in, query, user, component, or session) that you are trying to reference is unavailable.

Make sure the object is available for reference. For information on listing existing objects, see Listing Log File Analyzer Queries and Run-time Details.

SBL-LFA-00117

Object "%s" already exists. Please use another name.

An object by that name already exists.

Use another name for your object.

SBL-LFA-00118

Query "%s" finished abnormally.

The query finished abnormally, possibly due to corrupt log files or user intervention.

Re-run the query. If that does not work and the query is complex, try simplifying it.

SBL-LFA-00119

"%s" should not be used for naming.

The name you have specified cannot be used.

Use another combination of characters.

SBL-LFA-00120

Cannot interpret: "%s"

The name you have specified cannot be used in this place.

The LFA identified an error in your command syntax. For information on valid LFA commands, see About Running Log File Analyzer Commands.

SBL-LFA-00121

Token has a wrong value: "%s"

The specified value is invalid.

For information on valid LFA commands, see About Running Log File Analyzer Commands.

SBL-LFA-00122

Unknown issue.

There is an error in the command that you have entered.

For information on valid LFA commands, see About Running Log File Analyzer Commands.

SBL-LFA-00123

There is no file "%s".

The input file that you specified when starting the LFA does not exist.

Make sure the file exists and the filename and path is correct.

SBL-LFA-00124

Wrong format of the string: "%s".

The specified string is formatted incorrectly.

For information on valid LFA commands, see About Running Log File Analyzer Commands.

SBL-LFA-00125

Error parsing configuration file "%s".

The Log File Analyzer configuration file specified in the message text is missing.

Restart the LFA with another configuration file, or make sure the specified configuration file is available.

SBL-LFA-00126

Too many unrelated files are found following main server log file pattern: "%s".

The log files in the server log directory are inconsistent. More than one unrelated file fits the main server log file pattern that is used by the LFA to initialize the server model.

Remove all unrelated files and try again.

SBL-LFA-00127

Invalid usage of the command.

You have used the command incorrectly.

For information and links to the correct usage of LFA commands, see About Running Log File Analyzer Commands.

SBL-LFA-00128

Component with name "%s" could not be found.

The Log File Analyzer cannot translate the component name you entered into a component short name.

If this is a valid component, specify its short name in the LFA configuration file. For further information, see Configuring the Log File Analyzer.

SBL-LFA-00130

Language "%s" could not be initialized. Please see Log File Analyzer documentation for more information.

The language files in the locale directory on the Siebel Server might be missing or corrupt.

Review information on LFA log file language considerations. For further information, see About the Log File Analyzer.

SBL-LFA-00131

String with code "%s" could not be loaded. Please see Log File Analyzer documentation for more information.

The language files in the locale directory on the Siebel Server might be missing or corrupt.

Review information on LFA log file language considerations. For further information, see About the Log File Analyzer.

SBL-LFA-00132

Formatting string "%s" is not supported. Parameters for this string could not be extracted.

An error in the string makes it impossible for the Log File Analyzer to parse it properly.

If you cannot resolve the underlying issue that caused this error, contact Oracle Global Customer Support by creating a service request (SR) on My Oracle Support.

Siebel System Monitoring and Diagnostics Guide Copyright © 2013, Oracle and/or its affiliates. All rights reserved. Legal Notices.