Siebel System Administration Guide > Application Object Manager Administration > About Application Object Manager Parameters >

Application Object Manager Named Subsystem Parameters


The Application Object Manager can maintain several different values for a particular parameter by using named subsystems. For more information about named subsystems and named subsystem parameters, see About Named Subsystem Parameters. For information about configuring Application Object Manager named subsystem parameters, see Configuring Siebel Enterprise Server Named Subsystem Parameters.

Named Subsystems Used by Application Object Managers

Table 28 provides a partial list of named subsystems used by Application Object Managers.

Table 28. Named Subsystems Used by Application Object Managers
Named Subsystem
Alias
Type
Description

DataMart Datasource

DataMart

InfraDatasources

Datamart data source used by Application Object Manager components

Gateway Datasource

GatewayDataSrc

InfraDatasources

Gateway data source used by Application Object Manager components

Object Manager Cache

ObjMgrCache

InfraObjMgrCache

Cache parameters for Application Object Manager components

Server Datasource

ServerDataSrc

InfraDatasources

Server data source used by Application Object Manager components

LDAP Security Adapter

LDAPSecAdpt

InfraSecAdpt_LDAP

LDAP security adapter used for Application Object Manager authentication with directory servers

Named Subsystem Parameters

Table 29 provides a partial list of named subsystem parameters.

Table 29. Named Subsystem Parameters
Parameter Alias
Named Subsystem
Data Type
Description

DSConnectString

GatewayDataSrc

String

Specifies the host name of the Siebel Gateway Name Server.

The value $(GatewayAddress) for the parameter ConnectString of the GatewayDataSrc section of the Application Object Manager's configuration file is replaced at run time with the value for the named subsystem parameter DSConnectString. An incorrect setting for DSConnectString results in server administration being inaccessible from the Siebel Web Client.

DSConnectString

ServerDataSrc

String

Specifies the database connection information. On Oracle Database (native), this information is the service name from tnsnames.ora. On Microsoft SQL Server and IBM DB2, this information is the ODBC Datasource Name.

DSDockedFlg

ServerDataSrc

Boolean

When you create a new named subsystem for an Application Object Manager, you must set this parameter to True.

DSFileSystem

ServerDataSrc

String

Set this parameter to *FSM* to allow the use of the File System Manager server component for standard Siebel Web Clients.

DSMaxCursorSize

ServerDataSrc, GatewayDataSr, or DataMart

Integer

Sets the total number of rows that can be returned in a result set.

The parameter MaxCursorSize is set for the Application Object Manager component by using the named subsystem parameter DSMaxCursorSize. (The applicable subsystem corresponds to the component parameter OM - Data Source.) This parameter is valid only with IBM DB2 for OS/390 and z/OS.

For more information, see the description of the MaxCursorSize parameter in Parameters for Individual Data Source Sections.

DSPreFetchSize

ServerDataSrc, GatewayDataSr, or DataMart

Integer

Sets the number of rows that the Siebel application reads initially as part of a query execution.

The parameter PreFetchSize is set for the Application Object Manager component by using the named subsystem parameter DSPreFetchSize. (The applicable subsystem corresponds to the component parameter OM - Data Source.) This parameter is valid only with IBM DB2 for OS/390 and z/OS.

For more information, see the description of the PreFetchSize parameter in Parameters for Individual Data Source Sections.

DSEnterpriseServer

ServerDataSrc, GatewayDataSr

String

Specifies the name of the Siebel Enterprise Server used by various named subsystems. The value in the Application Object Manager is replaced at run time with the value set for the named subsystem.

DSRequestServer

ServerDataSrc

String

Specifies where asynchronous calls are redirected, for example when using Interactive Assignment. Set this value to the logical name of the Siebel Server, not the computer name. The default value is null.

DSTableOwner

All named subsystems of type InfraDatasources

String

Specifies the table owner for this data source. Application Object Manager server components, such as Call Center Object Manager, read the value of this parameter. Siebel Server infrastructure and system management components, such as Server Request Broker (SRBroker), read the value of the TableOwner enterprise parameter.

DSDisableExecuteRetry

ServerDataSrc

Boolean

When set to True, this parameter prevents the Application Object Manager from resending a query to the database layer if an error occurs such as a network error or session kill.

To configure named subsystems using the Siebel Server Manager command-line interface, see Named Subsystem Management Commands.

Siebel System Administration Guide Copyright © 2014, Oracle and/or its affiliates. All rights reserved. Legal Notices.