This chapter provides a list of the conversion programs that must be added to the scheduler and discusses how to add conversion programs to the scheduler.
For JD Edwards EnterpriseOne releases Xe through 8.12, you must add base currency conversion programs to the scheduler before you set up conversion plans and run the base currency conversion. The scheduler should contain a list of all of the conversion programs to be run at your site. You must add specific conversion programs for the systems that you use so that the scheduler list is complete and accurate for your release.
The conversion programs that must be added are described in tables in this section, by release.
Xe
For release Xe and the systems that you use, add the appropriate conversion programs from this list:
Table Number |
Conversion Program |
F1403 |
R891403E Also converts F1406 |
F1404 |
R891404E Also converts F14041 |
F15012 |
R8915012BE |
F15013 |
R8915013BE |
F15014 |
R8915014BE |
F15015 |
R8915015BE |
F15016 |
R8915016BE |
F1502 |
R891502BE |
F1502WB |
R891502WBE |
F1502 |
R891502BE |
F1505 |
R891505BE |
F1507 |
R891507E |
F1511 |
R891511BE |
F1511H |
R891511HBE |
F1513 |
R891513BE |
F1532B |
R891532BE |
F1538 |
R891538BE |
F1540 |
R891540BE |
F15410 |
R8915410E |
F1541B |
R891541BE |
F1543B |
R891543BE |
F1565 |
R891565E |
F159071 |
R89159071E |
F1755 |
R891755E |
F3908 |
R893908E |
F3910 |
R893910E |
F39061 |
R8939061E |
F390619 |
R89390619E |
F39062 |
R8939062E |
F39063 |
R8939063E |
F390639 |
R89390639E |
F39064 |
R8939064E |
F390649 |
R89390649E |
F39120W |
R8939120WE |
F39121W |
R8939121WE |
F44H101 |
R8944H101E |
F44H201 |
R8944H201E |
F44H301 |
R8944H301E |
F44H401 |
R8944H401E |
F44H4101 |
R8944H410E |
F44H501 |
R8944H501E |
F44H511 |
R8944H511E |
F44H591 |
R8944H591E |
F44H603 |
R8944H603E |
F44H611 |
R8944H611E |
F44H711 |
R8944H711E |
F44H711P |
R8944H711P |
F44H0929 |
R8944H929E |
F48S912 |
R8948S912E |
F49633 |
R894941E |
F49634 |
R894915E |
8.0
For release 8.0 and the systems that you use, add the appropriate conversion programs from this list:
Table Number |
Conversion Program |
F1403 |
R891403E Also converts F1406 |
F1404 |
R891404E Also converts F14041 |
F15012 |
R8915012BE |
F15013 |
R8915013BE |
F15014 |
R8915014BE |
F15015 |
R8915015BE |
F15016 |
R8915016BE |
F1502 |
R891502BE |
F1502WB |
R891502WBE |
F1505 |
R891505BE |
F1507 |
R891507E |
F1511 |
R891511BE |
F1511H |
R891511HBE |
F1513 |
R891513BE |
F1532B |
R891532BE |
F1538 |
R891538BE |
F1540 |
R891540BE |
F15410 |
R8915410E |
F1541B |
R891541BE |
F1541BW |
R891541BWE |
F1542 |
R891542E |
F1543B |
R891543BE |
F1565 |
R891565E |
F159071 |
R89159071E |
F15L100 |
R8915L100E |
F15L101 |
R8915L101E |
F15L102 |
R8915L102E Also converts F15L112 |
F15L105 |
R8915L105E |
F15L108 |
R8915L108E Also converts F15L118 |
F15L109 |
R8915L109E |
F15L113 |
R8915L113E |
F15L114 |
R8915L114E |
F15L301 |
R8915L301E |
F15L38 |
R8915L38E |
F1755 |
R891755E |
F3908 |
R893908E |
F3910 |
R893910E |
F39061 |
R8939061 |
F390619 |
R89390619E |
F39062 |
R8939062E |
F39063 |
R8939063E |
F390639 |
R89390639E |
F39064 |
R8939064E |
F390649 |
R89390649E |
F39120W |
R8939120WE |
F39121W |
R8939121WE |
F44H101 |
R8944H101E |
F44H201 |
R8944H201E |
F44H301 |
R8944H301E |
F44H401 |
R8944H401E |
F44H4101 |
R8944H410E |
F44H501 |
R8944H501E |
F44H511 |
R8944H511E |
F44H591 |
R8944H591E |
F44H603 |
R8944H603E |
F44H611 |
R8944H611E |
F44H711 |
R8944H711E |
F44H711P |
R8944H711P |
F44H0929 |
R8944H929E |
F48S912 |
R8948S912E |
F49633 |
R894941E |
F49634 |
R894915E |
F5280 |
R895280E |
8.9
For release 8.9 and the systems that you use, add the appropriate conversion programs from this list:
Table Number |
Conversion Program |
F1403 |
R891403E Also converts F1406 |
F1404 |
R891404E Also converts F14041 |
F15012 |
R8915012BE |
F15013 |
R8915013BE |
F15014 |
R8915014BE |
F15015 |
R8915015BE |
F15016 |
R8915016BE |
F1502 |
R891502BE |
F1502WB |
R891502WBE |
F1505 |
R891505BE |
F1507 |
R891507E |
F1511 |
R891511BE |
F1511H |
R891511HBE |
F1513 |
R891513BE |
F1532B |
R891532BE |
F1538 |
R891538BE |
F1540 |
R891540BE |
F15410 |
R8915410E |
F1541B |
R891541BE |
F1541BW |
R891541BWE |
F1542 |
R891542E |
F1543B |
R891543BE |
F1565 |
R891565E |
F159071 |
R89159071E |
F1755 |
R891755E |
F3908 |
R893908E |
F3910 |
R893910E |
F39061 |
R8939061E |
F390619 |
R89390619E |
F39062 |
R8939062E |
F39063 |
R8939063E |
F390639 |
R89390639E |
F39064 |
R8939064E |
F390649 |
R89390649E |
F39120W |
R8939120WE |
F39121W |
R8939121WE |
F48S912 |
R8948S912E |
F49633 |
R894941E |
F49634 |
R894915E |
F5280 |
R895280E |
8.10
For release 8.10 and the systems that you use, add the appropriate conversion programs from this list:
Table Number |
Conversion Program |
F1383 |
R891383E |
F1403 |
R891403E Also converts F1406 |
F1404 |
R891404E Also converts F14041 |
F15012 |
R8915012BE |
F15013 |
R8915013BE |
F15014 |
R8915014BE |
F15015 |
R8915015BE |
F15016 |
R8915016BE |
F1502 |
R891502BE |
F1502WB |
R891502WBE |
F1505 |
R891505BE |
F1507 |
R891507E |
F1511 |
R891511BE |
F1511H |
R891511HBE |
F1513 |
R891513BE |
F1532B |
R891532BE |
F1538 |
R891538BE |
F1540 |
R891540BE |
F15410 |
R8915410E |
F1541B |
R891541BE |
F1541BW |
R891541BWE |
F1542 |
R891542E |
F1543B |
R891543BE |
F1565 |
R891565E |
F159071 |
R89159071E |
F15L100 |
R8915L100E |
F15L101 |
R8915L101E |
F15L102 |
R8915L102E Also converts F15L112 |
F15L105 |
R8915L105E |
F15L109 |
R8915L109E |
F15L110 |
R8915L110E Also converts F15L111 |
F15L113 |
R8915L113E |
F15L114 |
R8915L114E |
F15L301 |
R8915L301E |
F15L302 |
R8915L302E |
F15L38 |
R8915L38E |
F1755 |
R891755E |
F3908 |
R893908E |
F3910 |
R893910E |
F39061 |
R8939061E |
F390619 |
R89390619E |
F39062 |
R8939062E |
F39063 |
R8939063E |
F390639 |
R89390639E |
F39064 |
R8939064E |
F390649 |
R89390649E |
F39120W |
R8939120WE |
F39121W |
R8939121WE |
F44H101 |
R8944H101E |
F44H201 |
R8944H201E |
F44H301 |
R8944H301E |
F44H401 |
R8944H401E |
F44H4101 |
R8944H410E |
F44H501 |
R8944H501E |
F44H511 |
R8944H511E |
F44H591 |
R8944H591E |
F44H603 |
R8944H603E |
F44H611 |
R8944H611E |
F44H711 |
R8944H711E |
F44H711P |
R8944H711P |
F44H0929 |
R8944H929E |
F48S912 |
R8948S912E |
F49633 |
R894941E |
F49634 |
R894915E |
F5280 |
R895280E |
8.11
For release 8.11 and the systems that you use, add the appropriate conversion programs from this list:
Table Number |
Conversion Program |
F1383 |
R891383E |
F1403 |
R891403E Also converts F1406 |
F1404 |
R891404E Also converts F14041 |
F15012 |
R8915012BE |
F15013 |
R8915013BE |
F15014 |
R8915014BE |
F15015 |
R8915015BE |
F15016 |
R8915016BE |
F1502 |
R891502BE |
F1502WB |
R891502WBE |
F1505 |
R891505BE |
F1507 |
R891507E |
F1511 |
R891511BE |
F1511H |
R891511HBE |
F1513 |
R891513BE |
F1532B |
R891532BE |
F1538 |
R891538BE |
F1540 |
R891540BE |
F15410 |
R8915410E |
F1541B |
R891541BE |
F1541BW |
R891541BWE |
F1542 |
R891542E |
F1543B |
R891543BE |
F1565 |
R891565E |
F159071 |
R89159071E |
F1755 |
R891755E |
FF31111 |
R89F31111E |
FF31113 |
R89F31113E |
FF31200 |
R89F31200E |
FF30L002 |
R89F30L02E |
F3908 |
R893908E |
F3910 |
R893910E |
F39061 |
R8939061E |
F390619 |
R89390619E |
F39062 |
R8939062E |
F39063 |
R8939063E |
F390639 |
R89390639E |
F39064 |
R8939064E |
F390649 |
R89390649E |
F39120W |
R8939120WE |
F39121W |
R8939121WE |
F4316 |
R894301E Also converts F4301, F4311, F4311T, F4316T, F4317 |
F43E01 |
R8943E01E Also converts F43E11, F43E16 |
F44H101 |
R8944H101E |
F44H201 |
R8944H201E |
F44H301 |
R8944H301E |
F44H401 |
R8944H401E |
F44H4101 |
R8944H410E |
F44H501 |
R8944H501E |
F44H511 |
R8944H511E |
F44H591 |
R8944H591E |
F44H603 |
R8944H603E |
F44H611 |
R8944H611E |
F44H711 |
R8944H711E |
F44H711P |
R8944H711P |
F44H0929 |
R8944H929E |
F48S912 |
R8948S912E |
F49633 |
R894941E |
F5280 |
R895280E |
F49634 |
R894915E |
F76V4025 |
R8976V3E |
F76V4030 |
R8976V4E |
8.11 SP1
For release 8.11 SP1 and the systems that you use, add the appropriate conversion programs from this list:
Table Number |
Conversion Program |
F1383 |
R891383E |
F1403 |
R891403E Also converts F1406 |
F1404 |
R891404E Also converts F14041 |
F15012 |
R8915012BE |
F15013 |
R8915013BE |
F15014 |
R8915014BE |
F15015 |
R8915015BE |
F15016 |
R8915016BE |
F1502 |
R891502BE |
F1502WB |
R891502WBE |
F1505 |
R891505BE |
F1507 |
R891507E |
F1511 |
R891511BE |
F1511H |
R891511HBE |
F1513 |
R891513BE |
F1532B |
R891532BE |
F1538 |
R891538BE |
F1540 |
R891540BE |
F15410 |
R8915410E |
F1541B |
R891541BE |
F1541BW |
R891541BWE |
F1542 |
R891542E |
F1543B |
R891543BE |
F1565 |
R891565E |
F159071 |
R89159071E |
F15L100 |
R8915L100E |
F15L101 |
R8915L101E |
F15L102 |
R8915L102E Also converts F15L112 |
F15L105 |
R8915L105E |
F15L109 |
R8915L109E |
F15L110 |
R8915L110E Also converts F15L111 |
F15L113 |
R8915L113E |
F15L114 |
R8915L114E |
F15L301 |
R8915L301E |
F15L302 |
R8915L302E |
F15L38 |
R8915L38E |
F1755 |
R891755E |
FF31111 |
R89F31111E |
FF31113 |
R89F31113E |
FF31200 |
R89F31200E |
FF30L002 |
R89F30L02E |
F3908 |
R893908E |
F3910 |
R893910E |
F39061 |
R8939061E |
F390619 |
R89390619E |
F39062 |
R8939062E |
F39063 |
R8939063E |
F390639 |
R89390639E |
F39064 |
R8939064E |
F390649 |
R89390649E |
F39120W |
R8939120WE |
F39121W |
R8939121WE |
F4316 |
R894301E Also converts F4301, F4311, F4311T, F4316T, F4317 |
F43E01 |
R8943E01E Also converts F43E11, F43E16 |
F44H101 |
R8944H101E |
F44H201 |
R8944H201E |
F44H301 |
R8944H301E |
F44H401 |
R8944H401E |
F44H4101 |
R8944H410E |
F44H501 |
R8944H501E |
F44H511 |
R8944H511E |
F44H591 |
R8944H591E |
F44H603 |
R8944H603E |
F44H611 |
R8944H611E |
F44H711 |
R8944H711E |
F44H711P |
R8944H711P |
F44H0929 |
R8944H929E |
F48S912 |
R8948S912E |
F49633 |
R894941E |
F49634 |
R894915E |
F5280 |
R895280E |
F76V4025 |
R8976V3E |
F76V4030 |
R8976V4E |
8.12
For release 8.12 and the systems that you use, add the appropriate conversion programs from this list:
Table Number |
Conversion Program |
F1383 |
R891383E |
F1403 |
R891403E Also converts F1406 |
F1404 |
R891404E Also converts F14041 |
F15012 |
R8915012BE |
F15013 |
R8915013BE |
F15014 |
R8915014BE |
F15015 |
R8915015BE |
F15016 |
R8915016BE |
F1502 |
R891502BE |
F1505 |
R891505BE |
F1507 |
R891507E |
F1511 |
R891511BE |
F1511H |
R891511HBE |
F1513 |
R891513BE |
F1532B |
R891532BE |
F1538 |
R891538BE |
F1540 |
R891540BE |
F15410 |
R8915410E |
F1541B |
R891541BE |
F1541BW |
R891541BWE |
F1542 |
R891542E |
F1543B |
R891543BE |
F1565 |
R891565E |
F159071 |
R89159071E |
F15L100 |
R8915L100E |
F15L101 |
R8915L101E |
F15L102 |
R8915L102E Also converts F15L112 |
F15L105 |
R8915L105E |
F15L109 |
R8915L109E |
F15L110 |
R8915L110E Also converts F15L111 |
F15L113 |
R8915L113E |
F15L114 |
R8915L114E |
F15L301 |
R8915L301E |
F15L302 |
R8915L302E |
F15L38 |
R8915L38E |
F1755 |
R891755E |
FF31111 |
R89F31111E |
FF31113 |
R89F31113E |
FF31200 |
R89F31200E |
FF30L002 |
R89F30L02E |
F3908 |
R893908E |
F3910 |
R893910E |
F39061 |
R8939061E |
F390619 |
R89390619E |
F39062 |
R8939062E |
F39063 |
R8939063E |
F390639 |
R89390639E |
F39064 |
R8939064E |
F390649 |
R89390649E |
F39120W |
R8939120WE |
F39121W |
R8939121WE |
F40G150 |
R8940G150E |
F4316 |
R894301E Also converts F4301, F4311, F4311T, F4316T, F4317 |
F43E01 |
R8943E01E Also converts F43E11, F43E16 |
F43Q10 |
R8943Q10E |
F43Q11 |
R8943Q11E |
F43Q20 |
R8943Q20E |
F43Q21 |
R8943Q21E |
F43Q40 |
R8943Q40E |
F43Q401 |
R8943Q401E |
F43Q41 |
R8943Q41E Also converts F43Q413 |
F43Q411 |
R8943Q411E |
F43Q412 |
R8943Q412E |
F43Q51 |
R8943Q51E |
F44H101 |
R8944H101E |
F44H201 |
R8944H201E |
F44H301 |
R8944H301E |
F44H401 |
R8944H401E |
F44H4101 |
R8944H410E |
F44H501 |
R8944H501E |
F44H511 |
R8944H511E |
F44H591 |
R8944H591E |
F44H603 |
R8944H603E |
F44H611 |
R8944H611E |
F44H711 |
R8944H711E |
F44H711P |
R8944H711P |
F44H0929 |
R8944H929E |
F48S912 |
R8948S912E |
F49633 |
R894941E |
F49634 |
R894915E |
F5280 |
R895280E |
F76V4025 |
R8976V3E |
F76V4030 |
R8976V4E |
This section provides an overview of the scheduler and discusses how to add conversion programs to the scheduler.
The system loads records from the Table Conversion - JDE Scheduler table (F9843) into the Table Conversion Scheduler table (F98405) when you set up a conversion plan. The F9843 table, which contains the base currency conversion programs, is not completely accurate. To update the F9843 table for releases Xe through 8.12, you must add several conversion programs to the Table Conversion Scheduler program (P98430).
Important! Ensure that the conversion programs in the scheduler are current and accurate before you set up any conversion plans.
Form Name |
FormID |
Navigation |
Usage |
Work with Table Conversion Scheduler |
W98430A |
In the Windows environment, Advanced Operations (GH9611), Table Conversion Scheduler |
Review a list of the conversion programs in the scheduler. |
Scheduler Revisions |
W98430B |
On the Work with Table Conversion Scheduler form, click Add. |
Add a conversion program to the scheduler. |
Access the Work with Table Conversion Scheduler form.
To update conversion programs in the scheduler:
On the Work with Table Conversion Scheduler form, enter 8 (euro conversion) in the Conversion Type field and click Find.
The system displays a list of base currency conversion programs.
Click Add.
For the remaining steps, refer to the list of scheduler conversion programs to add for your release.
On the Scheduler Revisions form, complete these fields:
Conversion Type. Enter 8 (euro conversion) to assign the base currency conversion type.
Table Name. Refer to the list from step 3.
From Release and To Release. Enter the same release number in these two fields.
Conversion Sequence Nbr. Enter the next available sequence number. To derive this number, locate the sequence number of the last conversion program in the scheduler and increment it by 1.
Dependent on Sequence.
Enter 0 (the default value) for this field for all conversion scheduler records except those for system 43Q tables (release 8.12 and above). Many of the system 43Q table conversion programs depend on the successful completion of previous conversion programs.
Specify these dependencies when you add scheduler records for system 43Q tables:
Table |
Dependency Sequence Number |
F43Q11 |
0 (no dependency) |
F43Q20 |
Conversion sequence number for table F43Q11. |
F43Q21 |
Conversion sequence number for table F43Q20. |
F43Q10 |
Conversion sequence number for table F43Q21. |
F43Q40 |
0 (no dependency) |
F43Q401 |
Conversion sequence number for table F43Q40. |
F43Q41 |
Conversion sequence number for table F43Q40. |
F43Q411 |
Conversion sequence number for table F43Q40. |
F43Q412 |
Conversion sequence number for table F43Q40. |
F43Q51 |
Conversion sequence number for table F43Q40. |
Conversion Program. Refer to the list from step 3.
Version. Enter XJDE0001 for all conversion scheduler records with the exception of the following. Enter ZJDE0001 for these conversion programs:
R8943Q10E
R8943Q11E
R8943Q20E
R8943Q21E
Click OK.
Repeat steps 2–5 for each conversion program identified in the list.
On the Work with Table Conversion Scheduler form, click Find to refresh the list of conversion programs.
Scroll down to the sequence numbers of the programs that you added to verify that they appear in the scheduler.