C H A P T E R  20

Using the Adaptec RAID Configuration Utility

This chapter describes how to use the Adaptec RAID Configuration Utility (ARCU), a BIOS-based utility used to create and manage controllers, disk drives and other devices, and arrays on systems equipped with an Adaptec-based disk controller. It contains the following sections:



caution icon Caution - On servers equipped with an Adaptec disk controller, all drives must be part of a volume before they can be used by the BIOS or the OS. Adaptec controllers support single-drive volumes that can be used for drives that are not part of a RAID array. See Chapter 21for more information.




Note - After making a change to a volume or drive (including hot-plug actions) while using the BIOS-based Adaptec RAID Configuration Utility (ARCU), a rescan of the drives is necessary to see the changes. This can be done using the Rescan Drives option or by simply navigating back to the ARCU main menu.


Many of the tasks described in this document can also be done using the Sun StorageTek RAID Manager graphical user interface (GUI). This is described in Parts I and II of this document.


Introduction to the Adaptec RAID Configuration Utility

The Adaptec RAID Configuration utility provides three tools:


Running the Adaptec RAID Configuration Utility

This section describes how to start and navigate through the Adaptec RAID Configuration utility. The section contains the following subsections:


procedure icon  To Start the Adaptec RAID Configuration Utility

1. Start an RKVM session, or connect a keyboard, mouse, and video device to the server module.

2. Power on or start the server module.

3. When prompted, press Ctrl-A.

The Adaptec RAID Controller Utility (ARCU) screen appears.

During bootup, if your system has insufficient memory, the following message appears.


BIOS RAID Configuration Utility will load after system initialization. Please wait... Or press <Enter> Key to attempt loading the utility forcibly [Generally, not recommended]



Note - The first time you power on your system after you install a new controller, the BIOS might display a configuration that does not match the system’s configuration. This is normal behavior.



procedure icon  To Navigate the Adaptec RAID Configuration Utility

single-step bullet  Use the arrow keys, Enter, Esc, and other keys on your keyboard to navigate through the utility menus.

All the tools within the Adaptec RAID Configuration utility are menu-based. Instructions for completing tasks are displayed onscreen.


Using the ACU to Create and Manage Arrays

You can use the ACU, a tool of the Adaptec RAID Configuration utility, to create and manage arrays. This section contains the following subsections:


procedure icon  To Start the ACU

1. Start the Adaptec RAID Configuration utility.

See To Start the Adaptec RAID Configuration Utility.

2. On the ARCU screen, select Array Configuration Utility and press Enter.

3. Follow the onscreen instructions to create and manage arrays, and initialize, rescan, and erase disk drives.


procedure icon  To Create a New Array With the ACU



Note - You can create an array with the ACU or with the Sun StorageTek RAID Manager GUI. However, creating an array using the GUI is up to three times as fast. For more information, see the Sun StorageTek RAID Manager Software User’s Guide.


1. Select Create Arrays from the main ACU menu.

Only disk drives that can be used in a new array are available for selection. (Disk drives must be initialized before they can be used in an array. See To Initialize Disk Drives With the ACU for more information.)

2. Use the Array Properties menu to modify the RAID level, size, name, stripe size, and caching settings of the array.



Note - Creating a new array might change the BIOS boot order. Check the BIOS settings to verify the correct boot order.



procedure icon  To Manage Existing Arrays With the ACU

1. Select Manage Arrays from the main ACU menu.

2. From the Manage Arrays menu, do any of the following:



Note - Failed drives are displayed in a different text color.




caution icon Caution - Before deleting an array, back up the data to avoid permanently losing it.



procedure icon  To Make an Array Bootable With the ACU



Note - You might need to change the system BIOS to modify the boot order. For more information, refer to your computer documentation.


1. Select Manage Arrays from the main ACU menu.

2. Select the array that you want to make bootable, and then press Ctrl-B.



Note - You cannot make an array bootable while it is building, verifying, or rebuilding.


The array number changes to Array 00, which makes the array the boot array.

3. Restart the computer.


procedure icon  To Initialize Disk Drives With the ACU

If a disk drive is grayed-out (unavailable for use in a new array), it might need to be initialized.

single-step bullet  Select Initialize Drives from the main ACU menu.



caution icon Caution - Do not initialize a disk drive that is part of an array. Initializing a disk drive that is part of an array might make the array unusable. Back up all data from your disk drive before you initialize it.



procedure icon  To Rescan Disk Drives With the ACU

single-step bullet  Select Rescan Drives from the main ACU menu.


procedure icon  To Perform a Secure Erase on Disk Drives With the ACU

When you perform a secure erase on a disk drive, all data on that disk drive is completely and irretrievably eradicated. Secure erase performs three distinct writing passes to the disk drive being erased--it does not just write zeros.

Performing a secure erase takes up to six times longer than clearing (or zeroing) a disk drive. You might want to perform a secure erase only on disk drives that contain confidential or classified information.



Note - To save time erasing a disk drive that does not contain sensitive information, you can format it, or clear it with the Sun StorageTek RAID Manager GUI. Both options take less time than the secure erase option, but might not offer enough security for highly sensitive information. See Using the Disk Utilities to Manage Disk Drives) to format a disk drive.


single-step bullet  Select Secure Erase from the main ACU menu, then select Y (yes).

To return to the main ACU menu after the secure erase has started, press Esc. The selected disk drive(s) cannot be used until the erase is complete.


procedure icon  To Stop a Secure Erase in Progress With the ACU

1. From the main ACU window, select Secure Erase.

2. Select the disk drive being secure erased, and then press Ctrl-Q.

The secure erase stops and the ACU returns to its main window.


Using the Select Utility to Modify Controller Settings

The ARCU includes a tool for modifying the controller settings, and for modifying the disk drives connected to it. This utility is called either SerialSelect (SAS) or SATASelect.

This section contains the following subsections:


procedure icon  To Start Using the Select Utility

1. Start the Adaptec RAID Configuration utility (see To Start the Adaptec RAID Configuration Utility).

The ARCU screen appears.

2. Select the Select utility and press Enter.

The utility might be named SerialSelect or SATASelect.

3. Follow the onscreen instructions to modify the settings of the controller and connected disk drives, as required.


procedure icon  To Apply Changes and Exit the Select Utility

1. Press Esc until you are prompted to exit.

If you modified any settings, you are prompted to save the changes before you exit.

2. Select Yes to exit, then press any key to restart your computer.

Any changes you made take effect after the computer restarts.


procedure icon  To Modify General Settings With the Select Utility

single-step bullet  Select Controller Configuration from the main Select utility menu and change the settings listed in the following table.

Some options might not be available.



Note - Default settings are shown in bold type.



TABLE 20-1 General Settings

Option

Description

Drive’s Write Cache

When enabled, write cache is enabled on the disk drive. When disabled, write cache is not used on the disk drive. It is recommended that you disable write cache on the disk drive.

Caution--When write cache is enabled, there is a slight possibility of data loss or corruption during a power failure.

Runtime BIOS

When enabled, this allows the controller to act as a bootable device. Disabling the BIOS allows another controller to act as a bootable device.

Automatic Failover

When enabled, the controller automatically rebuilds an array when a failed disk drive is replaced. When disabled, the array must be rebuilt manually.

Array Background Consistency Check

When enabled, the controller constantly verifies a redundant array. Note that there might be a significant performance reduction. Default is disabled.

BBS (BIOS Boot Sequence) Support

When enabled in systems that support BBS, the controller is presented as a bootable device in the BIOS.

Array-Based BBS Support

When enabled in systems that support BBS, the controller presents attached bootable devices up to the BIOS for boot device selection. This is relevant for logical arrays. Default is disabled.

Physical Drives Display During POST

When enabled, connected disk drives are displayed during system Power On Self Test (POST). Displaying the disk drives adds a few seconds to the overall POST time. Default is disabled.

CD-ROM Boot Support

When enabled, the system can be booted from a bootable CD.

Note--CDs are not supported by current software.

Removable Media Devices Boot Support

When enabled, removable media devices, such as CD drives, are supported.

Alarm Control

When enabled, the alarm sounds. Default is enabled.

Note--When the alarm is turned off (disabled), it automatically turns back on after a reboot.

SATA Native Command Queuing (NCQ)

When enabled, NCQ is enabled. Disable this feature if you want to attach more than 48 SATA II disk drives. Available only with SATA II disk drives.



procedure icon  To Modify SAS-Specific Controller Settings With the Select Utility

In addition to the general settings listed in To Modify General Settings With the Select Utility, some controllers have SAS-specific settings that can be modified if required.

single-step bullet  Select PHY Configuration from the SerialSelect main menu and change the settings listed in the following table.



Note - Default settings are shown in bold type.



TABLE 20-2 SAS-Specific Controller Settings

Option

Description

PHY Rate

The data transfer rate between the controller and devices. The default setting is Auto, which allows the SAS card to adjust the data transfer rate as required.

CRC Checking

When enabled, determines whether the controller verifies the accuracy of data transfer on the serial bus. Default setting is Yes (enabled). Set to No (disabled) only if the controller is connected to a device that does not support CRC Checking.

SAS Address

In a situation where you want each phy on a controller to be in a different SAS domain, this setting specifies a unique world-wide name for each phy. Default is 0.

Note: This setting is for SAS address conflict resolution only and must otherwise remain at its default value.


Using the Select Utility to Check Battery Status

The Select Utility has the ability to monitor the controller’s battery status.


procedure icon  To Check the Controller Battery Status

single-step bullet  Select Battery Unit Status from the Select Utility menu.

The utility displays the following information about the status of the battery.

The estimated remaining charge indicates how long the battery will continue to operate if the power fails.

 


Using the Disk Utilities to Manage Disk Drives

You can use the disk utilities tool to perform low-level formatting, or to verify your disk drives.



Note - New disk drives are low-level formatted at the factory and do not need to be low-level formatted again.




caution icon Caution - Before you format a disk drive, back up all data. Formatting destroys all data on a disk drive.


This section contains the following subsections:


procedure icon  To Format or Verify a Disk Drive With the Disk Utilities

1. Start the ARCU.

See To Start the Adaptec RAID Configuration Utility.

The ARCU screen appears.

2. On the ARCU screen, select Disk Utilities.

3. Select the disk drive you want, then press Enter.

4. Select Format Disk or Verify Disk Media.


procedure icon  To Locate Disk Drives With the Disk Utilities



Note - This feature is available only with disk drives that have an activity LED.


You can use the Identify Drive feature to physically locate a disk drive by blinking the LED.

1. Start the ARCU.

See To Start the Adaptec RAID Configuration Utility.

2. Select Disk Utilities.

3. Select the disk drive you want, then press Enter.

4. Select Identify Drive, then press Enter.

5. When you have finished locating your disk drive, press any key to stop the blinking.


procedure icon  To Identify Disk Drives With the Disk Utilities

You can identify disk drives by viewing the list of disk drives on your system. Only physical drives that appear during POST are shown.

1. Start the ARCU.

See To Start the Adaptec RAID Configuration Utility.

2. Select Disk Utilities.

The Disk Utilities view displays the following information:


TABLE 20-3 Information Provided by Disk Utilities

Location

Model

Rev#

Speed

Size

CN1=DEV1

Box0=Slot0

Exp0=phy0

The manufacturer information.

The revision number of the disk drive.

The speed of the disk drive.

The size of the disk drive.


 


Viewing the BIOS-Based Event Log

The BIOS-based event log records all firmware events, such as configuration changes, array creation, and boot activity.

Some events are not stored indefinitely. The event log is cleared of any non-persistent events each time you restart your computer. Also, when the log is full, new events overwrite old events.


procedure icon  To View the Event Log

1. Start the BIOS RAID Configuration utility.

See “Running the Adaptec RAID Configuration Utility.

2. Select the controller you want, then press Enter.

The BIOS RAID Configuration utility menu appears.

3. Press Ctrl+P.

4. Select Controller Log Information, then press Enter.

The current event log opens.