Configure ILOM Firmware Settings Using SNMP
|
Topics
|
|
Description
|
Links
|
Review the prerequisites
|
|
Configuring ILOM firmware interfaces
|
|
Related Topics
|
|
|
For ILOM
|
Section
|
Guide
|
|
- Configuration Management and Firmware Updates
|
Oracle Integrated Lights Out Manager (ILOM) 3.0 Concepts Guide (820-6410)
|
|
|
Oracle Integrated Lights Out Manager (ILOM) 3.0 Web Interface Procedures Guide (820-6411)
|
|
|
Oracle Integrated Lights Out Manager (ILOM) 3.0 CLI Procedures Guide (820-6412)
|
The ILOM 3.0 Documentation Collection is available at: http://docs.sun.com/app/docs/prod/int.lights.mgr30#hic
|
Before You Begin
Prior to performing the procedures in this chapter, you should ensure that the following requirements are met.
- Before you can use SNMP to view and configure ILOM settings, you must configure SNMP. For more information, see Preparing Your System to Use SNMP.
- To execute the snmpset command, you need to use an SNMP v1 or v2c community or an SNMP v3 user with read/write (rw) privileges.
- For examples of SNMP commands, see SNMP Command Examples.
Note - The example SNMP commands presented in this section are based on the Net-SNMP sample applications and, therefore, will only work as presented if you have Net-SNMP and the Net-SNMP sample applications installed.
|
Configuring ILOM Firmware Interfaces
View and Configure ILOM Firmware Settings
|
Note - You can use the get and set commands to view and configure ILOM firmware settings. For a description of the MIB objects used in these commands, see the SUN-ILOM-CONTROL-MIB.
|
1. Log in to a host that has an SNMP tool and the ILOM MIBs installed. For example, type:
ssh username@snmp_manager_ipaddress
Password: password
2. Refer to the following SNMP command examples:
- To view the version of the current firmware image, type:
% snmpget -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareMgmtVersion.0
|
- To view the build number of the current firmware image, type:
% snmpget -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareMgmtBuildNumber.0
|
- To view the build date and time of the current firmware image, type:
% snmpget -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareMgmtBuildDate.0
|
- To view the IP address of the TFTP server that will be used to download the firmware image, type:
% snmpget -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareTFTPServerIP.0
|
- To set the IP address of the TFTP server that will be used to download the firmware image, type:
% snmpset -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareTFTPServerIP.0 s ipaddress
|
- To view the relative path of the new firmware image file on the TFTP server, type:
% snmpget -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareTFTPFileName.0
|
- To set the relative path of the new firmware image file on the TFTP server, type:
% snmpset -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareTFTPFileName.0 s ‘tftpfilename’
|
- To view the property that determines whether the previous configuration of the server should be preserved after a firmware update, type:
% snmpget -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwarePreserveConfig.0
|
- To set the PreservConfig property to true so that the previous configuration of the server is preserved after a firmware update, type:
% snmpset -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwarePreserveConfig.0 i 1
|
- To view the property that indicates the status of a firmware update, type:
% snmpget -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareMgmtStatus.0
|
- To view the property that is used to initiate a firmware update using the values of the other firmware management properties as parameters, type:
% snmpget -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareMgmtAction.0
|
- To set the property so as to initiate a firmware update using the values of the other firmware management properties as parameters, type:
% snmpset -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareMgmtAction.0 i 2
|
- To clear the values of the other firmware management properties used if and when a firmware update is initiated, type:
% snmpset -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareMgmtAction.0 i 1
|
- To view the version of the current firmware management file system, type:
% snmpget -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareMgmtFilesystemVersion.0
|
- To view the property that is used to postpone the BIOS upgrade until the next server power off, type:
% snmpget -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareDelayBIOS.0
|
- To set the DelayBIOS property to postpone the BIOS upgrade until the next server power off, type:
% snmpset -mALL -v2c -cprivate SNMP_agent_ipaddress ilomCtrlFirmwareDelayBIOS.0 i 1
|
Oracle Integrated Lights Out Manager (ILOM) 3.0 Management Protocols Reference Guide SNMP, IPMI, WS-Man, CIM
|
820-6413-13
|
|