Oracle Integrated Lights Out Manager (ILOM) 3.0 Feature Updates and Release Notes
Feature Updates and Release Notes
820-7329-17
Contents |
Related ILOM 3.0 Documentation
2. Updates to the ILOM 3.0.3 Firmware
Resolved Issues as of ILOM 3.0.3
Alt-Graph Key Functionality on International Keyboards
Web Interface Does Not Display the Browse Button When Uploading Files
Newly Generated SSH Keys Require SSH Server Restart
Loading SSH Host Key Results in Error Message
Email Address Using IP Address Is Accepted in Alert Management Rule Query
When Using the CLI to Set the Time Zone, Certain Time Zones Do Not Recalculate the Clock Correctly (SPARC Servers)
BIOS Upgrade Is Delayed After SP Reboot
External Serial Port Settings Do Not Reset to Default Value
Hourly Power Average Timestamp Does Not Account for Increments of Less Than One Hour
SSH Keys Fail to Restore After a Backup/Restore
3. Updates to the ILOM 3.0.4 Firmware
Resolved Issues as of ILOM 3.0.4
LDAP or RADIUS Commands Do Not Work When Default Role Is Set to none
Difficulty Removing dnslocatorquery Records From Active Directory Configuration
When Using the CLI to Set the Time Zone, Certain Time Zones Do Not Recalculate the Clock Correctly (x86 Servers)
Snapshot Utility Missing Log Files for Debugging
ILOM CLI for set /{target}/config dump_uri Does Not Provide Confirmation Message
Role Help Text for Read-Only /SYS Properties Is Incorrect
Help Text for Power Management Properties Is Incorrect
Help Output Results for <TARGET> <property> <property> Is Confusing
Inaccurate Help Text Values for /SP/users/root/ssh/key/1-5
ILOM External Serial Port Flow Control Is Implemented Incorrectly
CLI Auto Completion for Read-Only Properties Does Not Work on Sun Fire X4140, X4240, and X4440 Servers
ILOM Remote Console Might Hang on Windows Client When Redirecting a CD-ROM Image or Floppy Image
Unrecoverable ILOM Remote Console Sessions
4. Updates to the ILOM 3.0.6 Firmware
Resolved Issues as of ILOM 3.0.6
Inability to Send SMTP Test Alert Email Notification
Inability to Navigate From CMM to Server Module After Disabling SSH
Power Management Events Are Not Recorded in Log File
Unable to Retrieve Host Power State After Upgrading ILOM Firmware From 2.0 to 3.0
Access Page Error Appears After Configuring Unknown Sensor LED Status When Monitoring System From IPMItool
Console Error Appears After Performing Backup and Restore
Windows Server 2008 R2 Generates System Event Log Warning Messages When Power Is Being Limited by ILOM Power Management
5. Updates to ILOM 3.0.8 Firmware
Resolved Issues as of ILOM 3.0.8
Invalid Time Zone Settings in ILOM CLI
Snapshot Properties Are Not Persistent After a Reset
Storage Redirection Not Supported With 64-bit JRE
5-Minute Delay to View Storage Monitoring Information
ILOM Version Not Shown When Using HIA to Upgrade ILOM From an Inband Management Interface
6. Updates to ILOM 3.0.9 Firmware
Resolved Issues as of ILOM 3.0.9
Unrecoverable ILOM Remote Console Sessions
DIMM FRU Data Fields Are Null After Downgrading or Upgrading SP Firmware Between 3.0.3 and 3.0.9
Invalid Help Command (help /SP system_contact=test) Results in Unusable Output
Service Snapshot Utility Unable to Collect SP Data When IE Web Browser Security Option Is Enabled
7. Updates to ILOM 3.0.10 Firmware
Resolved Issues as of ILOM 3.0.10
Invalid Help Command (help /SP system_contact=test) Results in Unusable Output
IPMItool sunoem CLI Might Be Denied If All Session Slots Are Busy
Known Issues as of ILOM 3.0.10
DVD Redirection From Solaris Client to RHEL Host Requires Manual Mount
Storage Redirection CLI Service Requires 32-bit JDK to Successfully Start
ILOM Remote Console Requires 32-bit JDK to Successfully Launch
ILOM Web Interface Unable to Connect to SP When Using Internet Explorer 6
8. Updates to ILOM 3.0.12 and ILOM 3.0.14 Firmware
New Features for ILOM 3.0.12 and ILOM 3.0.14
Resolved Issues as of ILOM 3.0.14
BIOS Upgrade Is Delayed After SP Reboot
External Serial Port Settings Do Not Reset to Default Value
Hourly Power Average Timestamp Does Not Account for Increments of Less Than One Hour
ILOM Remote Console Might Hang on Windows Client When Redirecting a CD-ROM Image or Floppy Image
Unable to Retrieve Host Power State After Upgrading ILOM Firmware From 2.0 to 3.0
Access Page Error Appears After Configuring Unknown Sensor LED Status When Monitoring System From IPMItool
Console Error Appears After Performing Backup and Restore
Windows Server 2008 R2 Generates System Event Log Warning Messages When Power Is Being Limited by ILOM Power Management
5-Minute Delay to View Storage Monitoring Information
ILOM Version Not Shown When Using HIA to Upgrade ILOM From an Inband Management Interface
DIMM FRU Data Fields Are Null After Downgrading or Upgrading SP Firmware Between 3.0.3 and 3.0.9
Service Snapshot Utility Unable to Collect SP Data When IE Web Browser Security Option Is Enabled
Updated Documentation Describing Storage Redirection 32-bit JDK Requirement
Updated Documentation Describing ILOM Remote Console 32-bit JDK Requirement
DVD Redirection From Solaris Client to RHEL Host Requires Manual Mount
ILOM Web Interface Unable to Connect to SP When Using Internet Explorer 6
Known Issues as of ILOM 3.0.14
Copyright © 2010, Oracle and/or its affiliates. All rights reserved.