Sun HPC 3.0 SCI Guide

Compare sm_config Output With Contents of sci_config.hpc

Compare the list of serial numbers in the sm_config output with the serial numbers in the temporary map you made of the actual network configuration. Verify that the adapter IDs and connection details you entered in Section 6 of sci_config.hpc correspond to your temporary network map. If not, change the contents of sci_config.hpc to correspond to physical configuration described by the temporary map.

When examining the sm_config output, also look for any error messages reported by sm_config or sm_configd.

If the sm_config output conflicts with Section 6 of the sci_config.hpc file, stop execution of sm_config (press Control-C) and correct the configuration file. Then run sm_config again and compare its output with sci_config.hpc again.

When the contents of the sci_config.hpc file are confirmed by the sm_config output, press Return to allow sm_config to complete execution.