System Administration | esmd(1m) |
| esmd - environmental status monitoring
daemon |
SYNOPSIS
|
esmd(1M) monitors system cabinet environmental conditions --for example, voltage, temperature, fan tray, and power supply. esmd logs abnormal conditions and takes action, if necessary, to protect the hardware.
This daemon is started automatically by the ssd(1M) daemon. Do not start it manually from the command line.
|
|
esmd monitors the following boards for out-of-range conditions:
- CPU board
- MaxCPU board
- HPCI board
- HPCI+ board
- Expander board
- Centerplane support board
- SC control board
- SC I/O
- Fan control board
- Power supplies (bulk)
esmd recognizes the following events and alerts the appropriate clients/daemons:
- Component insertion
- Notices component presence from one polling cycle to the next. esmd sends notification only if that client (hwad(1M), pcd(1M), dsmd(1M), and so on) has requested it for that particular component type.
- Component removal
- Notices component absence from one polling cycle to the next. esmd sends notification only if that client (hwad, pcd, and so on) has requested it for that particular component type.
- PCI card insertion
- Notices whenever a PCI card has been inserted into a PCI board.
- PCI card removal
- Notices whenever a PCI card has been removed from a PCI board.
- Board power off
- Notices whenever a board is powered off or when board power, previously on, is off.
- Board power on
- Notices when a board is powered on or when board power, previously off, is on.
- Board temperature change
- Notices when temperature sensors on a board register a two-degree difference or when a temperature crosses a temperature threshold.
- Board voltage change
- Notices if a voltage sensor value has changed so that it is close to being out of range and again if the new value is out of range. In this case esmd removes the board from the domain and powers it off.
- Board current change
- Notices whenever any of the monitored board current values change.
- CSB state change
- Notices when any of the monitored CSB board properties change.
- EXB state change
- Notices when any of the monitored EXB board properties change.
- CPU state change
- Notices when any of the monitored CPU board properties change.
- Bulk power state change
- Notices when any of the bulk power supply properties change.
- Fan tray state change
- Notices when any of the monitored fan tray properties change.
- PCI card state change
- Notices when any of the monitored PCI card properties change.
esmd clients include:
-
hwad
- Hardware access daemon
-
pcd
- Platform configuration database daemon
-
dsmd
- Domain status monitoring daemon
For more information refer to the System Management Services (SMS) 1.4.1 Administrator Guide.
|
|
The following exit values are returned:
-
0
- Successful completion.
- >0
- An error occurred.
|
|
The following file is supported.
-
/var/opt/SUNWSMS/adm/platform/messages
- Stores message files.
|
|
See attributes(5) for descriptions of the following attributes.
Attribute Types | Attribute Values |
Availability | SUNWSMSop |
|
|
dsmd(1m), hwad(1m), pcd(1m), ssd(1m)
|
SMS 1.4.1 | Go To Top | Last Changed 19 September 2003 |
Company Info
|
Contact
|
Copyright 2004 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, CA 95054 USA. All rights reserved.
|