This appendix provides physical, clearance and service, electrical, and environmental specifications.
The dimensions and weight of the system are as follows.
Table B-1|
|
U.S |
Metric |
Comments |
|---|---|---|---|
|
Height |
18.1 in |
46.0 cm |
20.4 in (51.7 cm) if equipped with floor casters |
|
Width |
10.3 in |
26.2 cm |
|
|
Depth |
27.1 in |
68.8 cm |
Power supply handles add 1.2 in (3.1 cm) |
|
Weight |
118 lb, max |
53 kg, max |
Actual weight depends on the installed options. |
|
Power Cord |
8.2 ft |
2.5 m |
|
Clearances needed when servicing the system are as follows.
Table B-2|
|
U.S |
Metric |
|---|---|---|
|
Front |
36 in |
91.44 cm |
|
Rear |
36 in |
91.44 cm |
|
Right |
36 in |
91.44 cm |
|
Left |
36 in |
91.44 cm |
|
Top |
36 in |
91.44 cm |
The operating and non-operating environmental requirements for the system are as follows.
Table B-3|
Parameter |
Value |
|---|---|
|
Operating |
|
|
Temperature |
5°C to 35°C (41°F to 95°F)--IEC 68-2-1, 68-2-2 |
|
Humidity |
20% to 80% RH, noncondensing; 27 °C max wet bulb--IEC 68-2-2, 68-2-3 |
|
Altitude |
0 to 3000 meters (0 to 10,000 feet)--IEC 68-2-40, 68-2-41 |
|
Vibration |
0.2 gravity (g) peak, 5-500 Hz (swept sine); 0.0002 g2/Hz, 5-500 Hz (random); vertical axis only (castered configuration); vertical and horizontal axes (foot glide configuration)--IEC 68-2-6 |
|
Shock |
4g peak, 11 milliseconds half-sine pulse--IEC 68-2-27 |
|
Declared Noise Emissions |
6.5/6.3 B (operating/idle)--ISO 9296 (LWAd) |
|
Non-Operating |
|
|
Temperature |
-20°C to 60°C (-4°F to 140°F)--IEC 68-2-1, 68-2-2 |
|
Humidity |
93% RH, noncondensing at 35°C--IEC 68-2-2, 68-2-3 |
|
Altitude |
0 to 12,000 meters (0 to 40,000 feet)--IEC 68-2-40, 68-2-41 |
|
Vibration |
1g peak, 5-500 Hz (swept sine); 0.002 g2/Hz, 5-500 Hz (random); 3 perpendicular axes--IEC 68-2-6 |
|
Shock |
15g peak, 11 milliseconds half-sine pulse--IEC 68-2-27e |
|
Threshold Impact |
1 m/s--SUN 900-1813 |
The system complies with the following specifications.
Table B-4|
Category |
Relevant Standards |
|---|---|
|
Safety |
EN60950/IEC950, TUV UL 1950, CB Scheme IEC 950, C22.2 No. 950 from UL |
|
RFI/EMI |
EN55022/CISPR22 Class B VCCI Class II FCC Part 15 Sub Part B |
|
Immunity |
EN50082/IEC-1000-2 IEC-1000-3 IEC-1000-4 IEC-1000-5 |
|
X-ray |
DHHS 21 Subchapter J PTB German X-ray Decree |
The following table provides the electrical specifications for the system.
Table B-5|
Parameter |
Value |
|---|---|
|
Input |
|
|
Nominal Frequencies |
50 Hz or 60 Hz nominal |
|
Nominal Voltage Range |
100 to 240 VAC |
|
Maximum Current AC RMS |
6.0 A @ 100 VAC |
|
AC Operating Range |
90 to 264 Vrms, 47 to 63Hz |
|
Output |
|
|
+1.8 to 3.0 VDC* |
3 to 27 A |
|
+3.3 VDC** |
3 to 34 A |
|
+5 VDC** |
2 to 30 A |
|
+12 VDC |
0.5 to 10 A |
|
-12 VDC |
0 to 0.5 A |
|
Maximum DC Power Output |
360 Watts |
|
Maximum AC Power Consumption |
580 Watts |
|
Maximum Heat Dissipation |
1980 BTUs/hr |
|
Volt-Ampere Rating |
600 VA with 360 Watt load |
|
* CPU core voltage. Actual voltage is determined by the specific CPU module(s) installed. |
|
|
** Combined output power of the +3.3 VDC and +5 VDC outputs must not exceed 170 Watts. |
|