A P P E N D I X  B

System Specifications

This appendix provides the following specifications for the Sun Fire V445 server:


Reference for Physical Specifications

The dimensions and weight of the system are as follows.


TABLE B-1 Dimensions and Weight

Measurement

U.S.

Metric

Height

6.85 in.

17.5 cm

Width

17.48 in.

44.5 cm

Depth

25 in.

64.4 cm

Weight:

Minimum

Maximum

 

70 lbs

82 lbs

 

31 kg

37.2 kg

Power Cord

8.2 ft

2.5 m



Reference for Electrical Specifications

The following table provides the electrical specifications for the system. All specifications pertain to a fully configured system operating at 50 Hz or 60 Hz.


TABLE B-2 Electrical Specifications

Parameter

Value

Input

 

Nominal Frequencies

50 or 60 Hz

Nominal Voltage Range

100 to 240 VAC

Maximum Current AC RMS *

13.2 A @ 100 VAC

11 A @ 120 VAC

6.6 A @ 200 VAC

6.35 A @ 208 VAC

6 A @ 220 VAC

5.74 A @ 230 VAC

5.5A @ 240 VAC

Output

 

+12 VDC

-12 VDC

+5 VDC

-5 VDC

0.5 to 45A

0 to 0.8A

0.5 to 28A

0.5 to 50A

Maximum DC Output of Two (2) Power Supplies

1100W Max AC power consumption 1320W for operation @ 100 VAC to 240 VAC Max heat dissipation 4505 BTUs/Hr for operation @ 200 VAC to 240 VAC.

Maximum AC Power Consumption

788W for operation @ 100 VAC to 240 VAC (maximum configuration)

Maximum Heat Dissipation

4505 Btu/hr for operation @ 100 VAC to 240 VAC


* Refers to total input current required for four AC inlets when operating with all four power supplies or current required for a dual AC inlet when operating with the minimum of two power supplies.


Reference for Environmental Specifications

The operating and nonoperating environmental specifications for the system are as follows.


TABLE B-3 Environmental Specifications

Parameter

Value

Operating

Temperature

5°C to 35°C (41°F to 95°F) noncondensingIEC 60068-2-1&2

Humidity

20% to 80% RH noncondensing; 27°C max wet bulbIEC 60068-2- 3&56

Altitude

Up to 3000 meters, max ambient temperature is derated by 1°C per 500 meters above 500 meters IEC 60068-2-13

Vibration (random)

0.0001 g2/Hz, 5 to 150 Hz, -12db/octave slope 150 to 500 Hz

Shock

3.0 g peak, 11 milliseconds half-sine pulseIEC 60068-2-27

Nonoperating

 

Temperature

-40°C to 60°C (-40°F to 140°F)noncondensingIEC 60068-2-1&2

Humidity

Up to 93% RH noncondensing; 38°C max wet bulbIEC 60068-2-3&56

Altitude

0 to 12,000 meters (0 to 40,000 feet)IEC 60068-2-13

Vibration

0.001 g2/Hz, 5 to 150 Hz, -12db/octave slope 150 to 500 Hz

Shock

15.0 g peak, 11 milliseconds half-sine pulse; 1.0 inch roll-off front to back, 0.5 inch roll-off side to sideIEC 60068-2-27

Handling Drops

60 mm, 1 drop per corner, 4 cornersIEC 60068-2-31

Threshold Impact

0.85m/s, 3 impacts per caster, all 4 casters, 25 mm step-upETE 1010-01



Reference for Agency Compliance Specifications

The system complies with the following specifications.


TABLE B-4 Agency Compliance Specifications

Category

Relevant Standards

Safety

UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part 1040, CNS14336

RFI/EMI

EN55022 Class A

47 CFR 15B Class A

ICES-003 Class A

VCCI Class A

AS/NZ 3548 Class A

CNS 13438 Class A

KSC 5858 Class A

EN61000-3-2

EN61000-3-3

Immunity

EN55024

IEC 61000-4-2

IEC 61000-4-3

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-6

IEC 61000-4-8

IEC 61000-4-11

Telecommunications

EN300-386

Regulatory Marking

CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-mark, UL/GS-mark



Reference for Clearance and Service Access Specifications

Minimum clearances needed for servicing the system are as follows.


TABLE B-5 Clearance and Service Access Specifications

Blockage

Required Clearance

Front of System

36 in (91.4 cm)

Back of System

36 in (91.4 cm)