Indication |
Test/Procedure |
Reference |
---|---|---|
System error message or device code identifies a specific fault |
Check system messages to locate failed drive.
|
|
Halt access to device and power down the device or array.
|
Internal drives: Chapter 7. Array: service manual for the array. |
|
|
Set ID code (if used) on replacement device before installing.
|
See Table C-2, or refer to drive or array documentation for ID code. |
|
If replaced unit is SPARCstorage Array or the array controller board, reset world-wide name (WWN).
|
Refer to SPARCstorage Array documentation. |
Device not identified or intermittent problem |
Run SunVTS.
|
Refer to SunVTS User's Guide. |
For SCSI device, use OpenBoot probe-scsi-all.
|
|
|
|
Check cable connection.
|
|
|
If replaced unit is SPARCstorage Array or the array controller board, reset world-wide name (WWN). |
|