Solstice Backup 5.1 Installation and Release Notes

Hints and Tips for Specific Autochanger Models

This section provides tips for how to use and configure several supported autochanger models.

Tips for the Optical Autochanger


# nsrjb -H
nsrjb: Autochanger error, Invert operation not supported

Use the following procedure to reset the autochanger:

  1. Enter the following command, and make a note of the output.


    # nsrjb -H
    

    This command displays information about the volumes loaded in the drive(s), the volume label(s), and the slots from which the volumes were loaded into the drive(s).

  2. Manually unload the volume from the device.

    Consult your autochanger hardware documentation for information on how to do this. The volume ends up in the cartridge access port with the "B" side facing up.

  3. Manually reinsert the volume into the cartridge access port, flipping them over so that the "A" side faces up.

  4. Use the control panel on the autochanger to reload the volume from the cartridge access port into the slot it originally came from.

  5. Reset the autochanger.


    # nsrjb -H
    

Tips for the ADIC 1200c Autochanger

Unlike most autochangers, the ADIC 1200c does not allow you to set the SCSI address of the autochanger (robotic arm) and the tape drive separately. You can only set the SCSI address of the tape drive. The SCSI address assigned to the autochanger is always three numbers higher than the tape drive address.

Tips for the HP C1533A and HP C1553A Autochangers

The following information applies specifically to the use of an HPC1533A or HP C1553A autochanger with Backup.

Tips and Suggestions for the EXB-60 CHS

The following tips and suggestions apply specifically to the use of an EXB-60 CHS with Backup.

Tips and Suggestions for the EXB-120 CHS

The following tips and suggestions apply specifically to the use of an EXB-120 CHS with Backup.