A P P E N D I X  A

System Specifications

To obtain maximum reliability and performance, install your server into a proper environment and ensure correct configuration as discussed in this chapter.


A.1 Specifications for the Sun Fire V20z Server

A.1.1 Physical Specifications

TABLE A-1 lists the physical specifications for the server.


TABLE A-1 Sun Fire V20z Server Physical Specifications

Specification

English

Metric

Width

16.94 in.

430.276 mm

Depth

28 in.

711.2 mm

Height

1.69 in.

42.93 mm

Weight (max.)

35 lbs

15.88 kg


Table lists the physical specifications of the Sun Fire V20z server.

A.1.2 Power Specifications

TABLE A-2 lists the power specifications for the server.


TABLE A-2 Sun Fire V20z Server AC Input Specifications

Specification

Value

Universal AC Input

100 to 240 VAC, 50/60 Hz

Maximum current

7.0 amps


Table lists the power specifications for the Sun Fire V20z server.

A.1.3 Environmental Specifications

TABLE A-3 lists the environmental specifications for the server.


TABLE A-3 Sun Fire V20z Server Unit-Level Environmental Specifications

Specification

State

English

Metric

Temperature

Operating

50° to 95° F

10° to 35° C[1]

Non-operating

-40° to 149° F

-40° to 65° C

Humidity

Operating

10% to 90% RH at 80. 6° F max. wet bulb (non-condensing)

10% to 90% RH at 27° C max. wet bulb (non-condensing)

Non-operating

10% to 90% RH

10% to 90% RH

Altitude

Operating

Up to 9,800 feet

Up to 3,000 meters

Non-operating

Up to 39,370 feet

Up to 12,000 meters

Vibration

Operating

.20 G, 5 to 500 Hz sine sweep

NA

Shock

Operating

5 G, 11 ms half-sine

NA


Table lists the unit-level environmental specifications for the Sun Fire V20z server.


A.2 Specifications for the Sun Fire V40z Server

A.2.1 Physical Specifications

TABLE A-4 lists the physical specifications for the server.


TABLE A-4 Sun Fire V40z Server Physical Specifications

Specification

English

Metric

Width

19 in.

482.60 mm

Depth

28 in.

711.20 mm

Height

5.25 in.

133.35 mm

Weight (max.)

75 lbs

34.0 kg


Table lists the physical specifications of the Sun Fire V40z server.

A.2.2 Power Specifications

TABLE A-5 lists the power specifications for the server.


TABLE A-5 Sun Fire V40z Server AC Input Specifications

Specification

Value

Universal AC Input

100 to 240 VAC, 47/63 Hz

Maximum current

10.0 amps


Table lists the power specifications for the Sun Fire V40z server.

A.2.3 Environmental Specifications

TABLE A-6 lists the environmental specifications for the server.


TABLE A-6 Sun Fire V40z Server Unit-Level Environmental Specifications

Specification

State

English

Metric

Temperature

Operating

50° to 95° F

10° to 35° C[2]

Non-operating

-40° to 149° F

-40° to 65° C

Humidity

Operating

10% to 90% RH at 80. 6° F max. wet bulb (non-condensing)

10% to 90% RH at 27° C max. wet bulb (non-condensing)

Non-operating

10% to 90% RH

10% to 90% RH

Altitude

Operating

Up to 9,800 feet

Up to 3,000 meters

Non-operating

Up to 39,370 feet

Up to 12,000 meters

Vibration

Operating

.20 G, 5 to 500 Hz sine sweep

NA

Shock

Operating

5 G, 11 ms half-sine

NA


Table lists the unit-level environmental specifications for the Sun Fire V40z server.

 


1 (TableFootnote) The temperature specifications in this table are rated for sea level. For each rise of 300 meters in altitude, the maximum temperature drops by 1° C.
2 (TableFootnote) The temperature specifications in this table are rated for sea level. For each rise of 300 meters in altitude, the maximum temperature drops by 1° C.