C H A P T E R 4 |
Maintaining the Sun Fire X2100 M2 Server |
This chapter describes how to add, replace, and configure components in the Sun Fire X2100 M2 Server after it has been set up.
This chapter contains the following sections:
To determine and isolate a faulty component, refer to Performing Diagnostics.
You need the following tools and supplies for performing Sun Fire X2100 M2 server maintenance procedures.
Before removing the system's top cover, read the following sections. These sections contain important electrostatic discharge (ESD) precautions, along with preinstallation and postinstallation instructions.
Electrostatic discharge (ESD) can damage your processor, disk drives, expansion boards, and other components. Always observe the following precautions before you install a system component.
Always perform the following steps before you install any component:
1. Turn off the system and all of the peripherals connected to it.
Caution - Failure to properly turn off the system before you start installing components can cause serious component damage. |
Caution - Follow the ESD precautions described in Section 4.2.1, ESD Precautionswhen handling a system component. |
See Section 4.3, Powering Off the Server and Removing the Cover for the appropriate procedure for opening the server.
Perform the following steps after installing a server component.
1. Ensure that all of the components are installed as described in the step-by-step instructions.
See Section 4.5, Component Replacement Procedures.
2. Reinstall any PCI-Express (PCIe) cards or peripherals that you had previously removed.
See Section 4.5, Component Replacement Procedures.
3. Reinstall the system's cover.
See Section 4.3, Powering Off the Server and Removing the Cover.
4. Connect all external cables to the system.
See Section 1.4, Powering On and Powering Off the Server.
For your safety, perform this procedure when you are powering off the system and removing the cover for a maintenance procedure in this chapter.
1. If the operating system (OS) is running, perform a shutdown of the OS, and then press and release the platform power button on the front panel.
2. Turn off all peripheral devices connected to the system.
3. Disconnect the AC power on the back panel of the server (see FIGURE 1-2).
4. Label and disconnect all peripheral cables and all telecommunication lines connected to I/O connectors or ports on the back panel of the system.
Caution - The system's printed circuit boards and hard disk drives contain components that are extremely sensitive to static electricity. |
5. Before handling components, attach a wrist strap to a chassis ground (any unpainted metal surface).
6. Loosen the two captive screws securing the cover to the chassis (see FIGURE 4-1).
7. Pull the cover slightly toward the back of the server and then straight up to remove it.
8. Lift the cover and remove it.
Refer to FIGURE 4-2 to locate components.
The following components are customer-replaceable units (CRUs):
The following components should be replaced only by trained field service technicians:
The following procedures describe how to remove and replace an I/O board.
1. Power off the server, including any attached peripherals, and disconnect the server from the electrical outlet. Refer to Section 4.3, Powering Off the Server and Removing the Cover.
2. Remove all cables connected to the I/O board.
3. Remove the screws securing the I/O board to the DVD cage.
4. Pull the I/O board back slightly, then upwards to disengage the board from the guides on top of the HDD cage.
1. Position the I/O board on top of the HDD cage so the openings on the board line up with the guides on top of the HDD cage.
2. Gently push the I/O board down to engage the guides and push the board forward to secure it.
3. Fasten the screws to secure the I/O board to the mounting bracket.
5. Before reinstalling the cover on the server, check the routing of all cables for obstructions.
The PCIe riser assembly that comes with the system can hold two low profile, half-length x8 PCI-Express (PCIe) cards with the following specifications:
The following procedures describe how to remove or install a PCIe card.
To remove the PCIe riser assembly and PCIe card:
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Placing your fingers on the two green areas on the riser card, pull the assembly upward and out of the chassis.
3. Unlatch the PCIe card and remove the card from the PCIe card riser assembly connector.
To install the PCIe card and riser card assembly:
1. If necessary, remove the riser card filler panel.
2. Connect the new PCIe in the riser assembly and fasten the latch to secure it.
3. Reinstall the riser assembly and card in the connector on the motherboard.
4. Check the routing of all cables for obstructions, and then reinstall the cover.
The following procedures describe how to remove and replace a hard disk drive (HDD) and carrier.
To remove the HDD and carrier:
1. If you are not using an integrated-mirroring configuration, you must power off the server before removing an HDD; it is not necessary to remove the cover. Power off the system as described in Section 4.3, Powering Off the Server and Removing the Cover.
If you are using an IM configuration, start with Step 2.
2. Squeeze the release latch and carefully swing the arm to the left as far as it will go.
3. Grasp the carrier bezel with both hands and carefully pull the carrier out of the drive bay.
4. Reinsert the HDD and carrier into the server as described in Section 4.5.3.2, Installing an HDD and Carrier.
To install the HDD and carrier:
1. Squeeze the release latch and carefully swing the arm to the left as far as it will go.
2. Grasping the body of the drive in both hands, carefully guide the connector end of the carrier into the drive bay, sliding the carrier into the bay until the arm engages and partially closes itself.
3. Push the arm forward and latch it to lock the carrier in place.
This section contains instructions on installing and LSI PCIe card. This card enables the following added functionality for the Sun Fire X2100 M2 server:
Use the appropriate procedure, depending on the hard drive format that you are using:
If your system originally had SATA drives installed or came diskless, and you would like to install SAS drives, use the following procedure.
You will need to order the following components needed for the SAS drive installation:
The following procedure describes how to remove the current SATA installation and install the SAS components. If you started with a diskless system, you do not need to do Step 2.
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Remove the current SATA hard drive(s) from the server, if necessary.
See Section 4.5.3.1, Removing an HDD and Carrier.
3. Reroute the hard drive cables. See FIGURE 4-12.
Note the following guidelines for cable removal and installation:
4. Remove the riser assembly from the server. See Section 4.5.2.1, Removing the Riser Assembly and PCIe Card.
5. Install the SAS card into the riser assembly. See Section 4.5.2.2, Installing the PCIe Card and Riser Card Assembly.
Do not install the riser card into the server yet. It will be easier to connect the cables with the card outside of the system.
6. Connect the SAS cables to the SAS card connectors. See FIGURE 4-13.
7. Install the riser assembly into the server. See Section 4.5.2.2, Installing the PCIe Card and Riser Card Assembly.
9. Install the SAS hard drives.
See Section 4.5.3.2, Installing an HDD and Carrier.
This section describes how to add the LSI PCIe card and cables to a system using SATA hard disks. The LSI card will support SATA hard disks attached to it. This configuration will only be used for customers who require a true SATA RAID configuration.
You will need to order the following components:
The following procedure describes how to add the LSI PCIe card and cables to connect to the SATA hard disks.
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Reroute the hard drive cables. See FIGURE 4-14.
Note the following guidelines for cable removal and installation:
3. Remove the riser assembly from the server. See Section 4.5.2.1, Removing the Riser Assembly and PCIe Card.
4. Install the LSI PCIe card into the riser assembly. See Section 4.5.2.2, Installing the PCIe Card and Riser Card Assembly.
Do not install the riser card into the server yet. It will be easier to connect the cables with the card outside of the system.
5. Connect the SATA cables to the LSI PCIe card connectors. See FIGURE 4-13.
6. Install the riser assembly into the server. See Section 4.5.2.2, Installing the PCIe Card and Riser Card Assembly.
8. Install the SATA hard drives, if necessary.
See Section 4.5.3.2, Installing an HDD and Carrier.
The following procedure describes how to replace the optical disk drive (ODD) assembly. If you are not replacing a DVD drive, go straight to Section 4.5.5.2, Installing the ODD Drive Assembly.
To remove an ODD (DVD or CD) drive assembly:
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Unfasten the drive ribbon cable from the ODD drive.
Caution - Use care with the small flat cables. They are extremely fragile. |
3. Push the latch on the back of the ODD drive toward the drive until the ODD drive springs forward out of the chassis.
4. Pull the ODD drive out the front of the chassis.
Caution - Move the assembly by grasping it by its sides. Do not push on the
|
To install the ODD (DVD or CD) drive assembly:
1. If necessary, remove the filler panel in front of the ODD drive slot on the front panel.
Put your finger or a screw driver behind the slot on the right side of the filler panel and pull the panel outward.
2. Position the ODD drive in front of the ODD drive slot on the front panel.
3. Push the ODD drive into the drive slot until the drive clicks into place.
4. Reinstall the ODD drive cable.
5. Check the routing of all cables for obstructions, and then reinstall the cover.
The following procedures describe how to replace the system air duct.
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Remove the screw fastening the air duct to the chassis divider.
1. Position the air duct as shown in FIGURE 4-20, aligning the baffle with the screw hole and opening in chassis divider.
2. Fasten the screw that attaches the air duct to the chassis divider.
The following procedures describe how to replace the power supply.
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Disconnect the two power-supply cables from the motherboard and power supply connections to the hard drives.
3. Remove the bracket with the captive screw.
5. Lift the power supply out of the chassis.
1. Position the power supply over the chassis power-supply cage.
2. Insert the power supply into the chassis and push it forward so that it is flush with the back panel.
3. Install the power supply bracket on top of the power supply tab and fasten the captive screw.
4. Connect two of the power supply cables to the motherboard and one cable to the SATA backplanes.
5. Check the routing of all cables for obstructions, and then reinstall the cover.
The following procedures describe how to replace a single system fan module.
To remove a system fan module:
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Pull the fan upward to remove it.
3. Unplug the fan's power connector from the connector on the fan harness.
To install a system fan module:
1. Position the fan so that the arrow on top of the fan casing is facing the middle chassis divider.
2. Place the fan in the chassis so that it fits over the small guideposts.
3. Gently push the fan down to secure it to the chassis.
4. Connect the fan connector to the appropriate connector on the fan harness.
Note - Note exactly which motherboard connector to which the fan was connected. If you connect a fan to an incorrect connector, the SP cannot correctly identify a fan failure. |
5. Check the routing of all cables for obstructions, and then reinstall the cover.
The following procedures describe how to replace a dual blower module.
To remove a dual blower module:
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Remove the single fan connectors from the harness connectors.
3. Remove all cables from the blower retention clips before removing the blower modules.
4. Push in the tabs on both sides of the dual blower module and simultaneously pull the fan module upward to remove it.
5. Unplug the fan's power connector from the motherboard.
To install the dual blower module:
1. Position the dual fan module so that it fits over the guideposts and the duct opening fits into the cutouts in the chassis divider.
2. Gently push the blower module down, until you hear the side tabs click into place.
3. Connect the blower connectors to the appropriate connectors on the motherboard.
4. Connect each of the single fan connectors to the corresponding fan harness connector.
5. Check the routing of all cables for obstructions, and then reinstall the cover.
The following procedure describes how to remove and or install dual inline memory modules (DIMMs).
Note - Keep in mind the following information and rules when you use the procedures in this section to replace or add DIMMs to the server. |
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Locate the DIMM connector in which you will install or replace a memory module.
3. Remove a DIMM by pressing down on the ejector bars at both ends of the memory module's socket (see FIGURE 4-28).
1. Refer to Section 4.5.10.1, DIMM Population Rules before installing DIMMs.
2. Ensure that the DIMM socket's ejectors are open (rotated outward) to allow the new module to be inserted.
3. Align the DIMM's edge connector with the alignment key and insert the memory module into the connector.
4. Using both thumbs, press the DIMM straight down into the DIMM slot until both ejector levers click, locking the DIMM in the DIMM slot.
Note - The manufacturer and capacity of both modules in the same memory bank must be identical. |
5. Check the routing of all cables for obstructions, and then reinstall the cover.
The system battery is a common CR2032 calculator battery.
You might need to replace the system battery if you know it is weak or if after any period of AC power loss, the BIOS loses its CMOS settings, or if the time-of-day clock loses time.
Caution - Do not attempt to open or service batteries. The battery contains lithium and can explode if not properly used, handled, or disposed of. |
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Pry the battery out of the system with a screwdriver as shown in FIGURE 4-30.
1. Insert the new system battery into the holder with the side labeled "+" facing upwards.
2. Check the routing of all cables for obstructions.
The following procedure describes how to replace a CPU.
Note - Replacement of a CPU and heatsink should only be done by trained service personnel. |
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Remove the air duct as shown in Section 4.5.6, Replacing an Air Duct.
3. Unfasten the four screws securing the heatsink to the board (see FIGURE 4-32).
Caution - The heatsink can become extremely hot. Be sure it has had sufficient time to cool before handling. |
4. Twist the heatsink slightly to the right or left to break the seal with the thermal grease.
5. Lift the heatsink away from the CPU.
6. Place the heatsink upside-down on a flat surface to prevent the thermal grease from contaminating other components.
7. Pull the socket release lever up to the fully open, perpendicular position.
9. Lift the CPU out of the socket, leaving the release lever in the open position.
Note - Ensure that no thermal grease that might be left from the heatsink comes into contact with the CPU socket or underside of the CPU chip. |
Follow these steps to install a CPU and heatsink if you are replacing a CPU.
Caution - Observe the appropriate ESD precautions in Section 4.2.1, ESD Precautionswhen handling the CPU. |
2. Ensure that the socket release lever is in the fully open, perpendicular position and the CPU cover is open (see FIGURE 4-34).
3. Align the small triangle, on the upper left corner of the CPU, with the triangle on the corner of the socket.
4. Insert the CPU into the socket.
5. When the CPU is fully seated in the socket, close the CPU cover.
The CPU cover might not align correctly with the chip, after it is installed. If this happens open the cover, and push it slightly to the side to better align it with the chip, and reclose the cover.
6. Rotate the socket release lever down until it snaps into place, securing the CPU in the socket.
7. Use the syringe to apply approximately 0.1 ML/CC of thermal grease in a circular pattern to the top of the CPU.
8. Gently distribute the thermal grease and remove any excess so that only an extremely thin, uniform layer remains. If any voids or crevices appear that could lead to air pockets, reapply the grease until you achieve a thin but compact consistency.
9. Use an alcohol pad to remove all thermal grease from the bottom of the heatsink.
10. Inspect the heatsink for dust and lint. Clean if necessary.
11. Carefully position the heatsink on the CPU, aligning it with the mounting posts to reduce movement after it makes initial contact with the layer of thermal grease.
Caution - If the heatsink is moved too much during its installation, the layer of thermal grease may become uneven, leading to component damage. |
12. Fasten the four screws attaching the heatsink to the motherboard. See FIGURE 4-35.
13. Replace the air duct. See Section 4.5.6, Replacing an Air Duct.
FIGURE 4-36 and FIGURE 4-37 shows the routing of the cables and motherboard connector locations.
The following table describes the cables that are included with the associated component replacement kits.
The following procedures describe how to remove and install the Sun Fire X2100 M2 server system motherboard.
Note - The motherboard is not a CRU and should be replaced only by trained field service technicians. |
1. Power off the system and remove the cover as described in Section 4.3, Powering Off the Server and Removing the Cover.
2. Remove the PCIe card riser installed on the motherboard (see Section 4.5.2, Replacing the PCIe Card and Riser Assembly) and the air duct (see Section 4.5.6, Replacing an Air Duct).
3. Disconnect all cables attached to the motherboard.
4. Remove the four screws from the heatsink.
Note - Do not remove the screws that secure the CPU heatsink assemblies mounting to the motherboard. |
5. Remove the five Phillips screws that fasten the motherboard to the chassis.
6. Remove the screws attaching the serial connector to the chassis with a 5 mm nut driver.
7. Pull the motherboard away from the chassis.
8. Remove the CPU and memory modules.
Refer to the following sections for information on removing and replacing the CPU and memory:
Caution - Observe proper ESD precautions in Section 4.2.1, ESD Precautionswhen handling the new motherboard. |
1. Center the motherboard on the chassis so that the screw holes in the motherboard align with the screw holes on the chassis.
2. Secure the five Phillips screws that fasten the motherboard to the chassis. Torque screws to 8- to 9-inch pounds.
3. Secure the screws attaching the serial connector to the chassis with a 5 mm nut driver.
4. Replace the CPU and DIMMs as necessary.
Refer to the following sections for information on removing and replacing the CPU and memory:
5. Replace the PCIe riser assembly and air baffle.
6. Reconnect all internal system cables.
See Section 4.5.13, Replacing Cables.
8. Replace any external cables and power on the server.